Programming Guide

Spectra 1759MG - 29 - Programming Guide
Programming Chime Zones
This feature allows users to program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to
emit a rapid intermittent beep tone (
BEEP-BEEP-BEEP-BEEP) advising the user every time it is opened. Each keypad must be
Chime Programmed separately. Keypad chimes must be re-programmed if the system suffers a total power loss (16-zone LED
and LCD Keypads only).
10-Zone LED Keypad
Press and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example,
press and hold the [1] key to enable chiming on zone 1. If, after pressing and holding a key, the keypad emits a confirma-
tion beep, this means the chime feature has been enabled for that zone. If the keypad emits a Rejection Beep, this means
the Chime feature has been disabled for the corresponding zone.
16-Zone LED Keypad
Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s). When the corresponding LED is on, the zone is
chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press [
ENTER].
LCD Keypad
Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s) or use the arrow keys to scroll through the zones.
When the appropriate zone is displayed, press the [
FNC1] key. When the desired zones are chimed, press [ENTER].
Keypad Muting
Press and hold the [CLEAR] key for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep
when a key is pressed or when the keypad emits a Rejection or Confirmation Beep. All other beep functions are disabled.
Keypad Backlight (1686H and 1686V Only)
The illumination level behind the keys can be modified to suit the users needs. There are four backlight levels. The [MEM] key
is used to set the desired level. Each consecutive push of the [
MEM] key will increase the backlight level until the maximum
level is reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is
repeated. To change the backlight level:
Quick Function Keys
Installer Test Mode
[
ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]
The Installer Test Mode allows you to perform walk tests where the bell/siren will squawk once to indicate an open zone and
twice to indicate a closed zone. To enter this mode, press [
ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]. The keypad will
emit a Confirmation Beep. To disable this mode, press the [
TBL] or [TRBL] key again. The keypad will emit a Rejection Beep.
Test Report
[
ENTER] + [INSTALLER/MASTER CODE] + [MEM]
Sends the Test Report report code programmed in section [211] to the central station.
Call WinLoad Software
[
ENTER] + [INSTALLER/MASTER CODE] + [BYP]
This feature is used to establish communication between the control panel and a computer using the WinLoad Software.
After entering this mode, the control panel will dial the telephone number programmed in section [150].
Cancel Communication
[
ENTER] + [INSTALLER/MASTER CODE] + [STAY]
Cancels all communication until the next reportable event. If the Master Code was used, only communication with WinLoad
would be cancelled.
Answer WinLoad Software
[
ENTER] + [INSTALLER/MASTER CODE] + [FORCE]
Forces the control panel to pick-up an incoming telephone call.
How do I Modify the Backlight?
1) Press and hold the [MEM] key for 3 seconds
2) The [
MEM] key will illuminate
3) Press the [
MEM] key to set the desired backlight level
4) Press [
CLEAR] or [ENTER] to exit