Spectra 1759MG - 30 - Programming Guide
Appendix A - Ademco CID Report Code List (Prog.)
If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below (Prog.
Value) into sections [160] to [213] to program the desired report codes. To enter a 0 value press the [
FORCE] key.
CID# Reporting Prog.
Code Value
CID# Reporting Prog.
Code Value
CID# Reporting Prog.
Code Value
MEDICAL ALARMS - 100 203 Gate Valve Sensor 2E 401 O/C by User 5B
100 Medical Alarm 01 204 Low Water Level 2F 402 Group O/C 5C
101 Pendant Transmitter 02 205 Pump Activated 30 403 Automatic O/C 5D
102 Fail to Report In 03 206 Pump Failure 31 404 Late to O/C 5E
FIRE ALARMS - 110 SYSTEM TROUBLES - 300 & 310 405 Deferred 5F
110 Fire Alarm 04 300 System Trouble 32 406 Cancel 60
111 Smoke 05 301 AC Loss 33 407 Remote Arm/Disarm 61
112 Combustion 06 302 Low System Battery 34 408 Quick Arm 62
113 Water Flow 07 303 RAM Checksum Bad 35 409 Keyswitch O/C 63
114 Heat 08 304 ROM Checksum Bad 36 REMOTE ACCESS - 410
115 Pull Station 09 305 System Reset 37 411 Callback Request Made 64
116 Duct 0A 306 Panel Program Changed 38 412 Success - Download Access 65
117 Flame 0B 307 Self-Test Failure 39 413 Unsuccessful Access 66
118 Near Alarm 0C 308 System Shutdown 3A 414 System Shutdown 67
PANIC ALARMS - 120 309 Battery Test Failure 3B 415 Dialer Shutdown 68
120 Panic Alarm 0D 310 Ground Fault 3C ACCESS CONTROL - 420
121 Duress 0E SOUNDER/RELAY TROUBLES - 320 421 Access Denied 69
122 Silent 0F 320 Sounder Relay 3D 422 Access Report By User 6A
123 Audible 10 321 Bell 1 3E SOUNDER RELAY DISABLES - 520
BURGLAR ALARMS - 130 322 Bell 2 3F 520 Sounder/Relay Disabled 6B
130 Burglary 11 323 Alarm Relay 40 521 Bell 1 Disable 6C
131 Perimeter 12 324 Trouble Relay 41 522 Bell 2 Disable 6D
132 Interior 13 325 Reversing 42 523 Alarm Relay Disable 6E
133 24-Hour 14
SYSTEM PERIPHERAL TROUBLES - 330 & 340
524 Trouble Relay Disable 6F
134 Entry/Exit 15 330 System Peripheral 43 525 Reversing Relay Disable 70
135 Day/Night 16 331 Polling Loop Open 44 COMMUNICATION DISABLES - 550 & 560
136 Outdoor 17 332 Polling Loop Short 45 551 Dialer Disabled 71
137 Tamper 18 333 Exp. Module Failure 46 552 Radio xmitter Disabled 72
138 Near Alarm 19 334 Repeater Failure 47 BYPASSES - 570
GENERAL ALARMS - 140 335 Local Printer Paper Out 48 570 Zone Bypass 73
140 General Alarm 1A 336 Local Printer Failure 49 571 Fire Bypass 74
141 Polling Loop Open 1B COMMUNICATION TROUBLES - 350 & 360 572 24-Hour Zone Bypass 75
142 Polling Loop Short 1C 350 Communication 4A 573 Burg. Bypass 76
143 Expansion Module Failure 1D 351 Telco Fault 1 4B 574 Group Bypass 77
144 Sensor Tamper 1E 352 Telco Fault 2 4C TEST/MISC. - 600
145 Expansion Module Tamper 1F 353 Long Range Radio 4D 601 Manual Trigger Test 78
24-HOUR NON-BURGLARY - 150 & 160 354 Fail to Communicate 4E 602 Periodic Test Report 79
150 24-Hour Non-Burglary 20 355 Loss of Radio Supervision 4F 603 Periodic RF Xmission 7A
151 Gas Detected 21 356 Loss of Central Polling 50 604 Fire Test 7B
152 Refrigeration 22 PROTECTION LOOP TROUBLES - 370 605 Status Report to Follow 7C
153 Loss of Heat 23 370 Protection Loop 51 606 Listen-in to Follow 7D
154 Water Leakage 24 371 Protection Loop Open 52 607 Walk Test Mode 7E
155 Foil Break 25 372 Protection Loop short 53 621 Event Log Reset 7F
156 Day Trouble 26 373 Fire Trouble 54 622 Event Log 50% Full 80
157 Low Bottled Gas Level 27 SENSOR TROUBLES - 380 623 Event Log 90% Full 81
158 High Temp 28 380 Sensor Trouble 55 624 Event Log Overflow 82
159 Low Temp 29 381 Loss of Super. -RF 56 625 Time/Date Reset 83
161 Loss of Air Flow 2A 382 Loss of Super. - RPM 57 626 Time/Date Inaccurate 84
FIRE SUPERVISORY - 200 & 210 383 Sensor Tamper 58 627 Program Mode Entry 85
200 Fire Supervisory 2B 384 RF xmtr. Low Battery 59 628 Program Mode Exit 86
201 Low Water Pressure 2C OPEN/CLOSE - 400 631 Exception Schedule Change 87
202 Low CO2 2D 400 Open/Close 5A 654 System Inactivity 88