Programming Guide

Spectra 1759MG - 6 - Programming Guide
Zone Programming
When programming zones, the zone assignments are dependent on where the detection devices are connected to in the
system (see Zone Recognition Table). In installations that require using mostly the expansion inputs, refer to Reassign
Keypad Zone 2 (see section [126] option [7] on page 12) and Reassign zones to expansion inputs (see section [126] option
[8] on page 12).
.
Do not assign inputs from different modules to the same expansion input.
Zone Recognition Table
Option [7]: OFF
Option [8]: OFF
Option [7]: ON
Option [8]: OFF
Option [7]: OFF
Option [8]: ON
Option [7]: ON
Option [8]: ON
Control Panel
Input 1 =
Zone 1 Zone 1 Zone 1 Zone 1
Input 2 =
Zone 2 Zone 2 Zone 2 Zone 2
Input 3 =
Zone 3 Zone 3 N/A N/A
Input 4 =
Zone 4 Zone 4 N/A N/A
Input 5 =
Zone 5 Zone 5 N/A N/A
Keypad
Zone 1 =
Zone 6 Zone 6 Zone 3 Zone 3
Zone 2 =
Zone 7 N/A Zone 4 N/A
Expansion
Input 1 =
Zone 8 Zone 7 Zone 5 Zone 4
Input 2 =
Zone 9 Zone 8 Zone 6 Zone 5
Input 3 =
Zone 10 Zone 9 Zone 7 Zone 6
Input 4 =
Zone 11 Zone10 Zone 8 Zone 7
Input 5 =
Zone 12 Zone 11 Zone 9 Zone 8
Input 6 =
Zone 13 Zone 12 Zone 10 Zone 9
Input 7 =
Zone 14 Zone 13 Zone 11 Zone 10
Input 8 =
Zone 15 Zone 14 Zone 12 Zone 11
= not displayed on 10-Zone LED Keypads
Option [7] = Reassign Keypad Zone 2
Option [8] = Reassign zones to expansion inputs