Programming Guide
Table Of Contents
- Default Installer Code
- Default System Master Code
- How Do I Enter Programming Mode?
- Decimal and Hexadecimal Programming Table
- Trouble Display
- Data Display Mode (LED Keypads Only)
- Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)
- Zone Programming
- System Timers
- Programmable Outputs
- System Options
- Communication Settings
- Report Codes
- System Settings
- User Code Options
- Reprogram All Modules
- Paradox Memory Key (PMC-3)
- 4-PGM Output Modules V2.0
- Printer Module V2.0
- Voice-assisted Arm/Disarm Bus Module V2.0
- Wireless Features
- Zone Expansion Bus Modules
- User Operation
- Appendix A - Ademco CID Report Code List (Prog.)
- Appendix B - Ademco CID Report Code List (All Codes)
- Bus Module Connections
- Hardware Connections
Spectra 1759MG - 7 - Programming Guide
Only the control panel’s on-board inputs can be defined as a Fire, Delayed Fire or a Keyswitch zone.
The on-board zones are zones 01 to 05. To program a wireless fire zone, refer to Programming a Wireless Fire
Zone on page 36.
How Do I Program the Zones?
1) Press the [ENTER] key
2) Enter the [
INSTALLER CODE] (Default: 0000 / 000000)
3) Enter 3-digit [
SECTION]
4) Enter one digit from the Zone Definition table (see page 7)
5) Enter one digit from the Partition Assignment table (see page 7)
6) Select one or more options from the Zone Options table (see page 7)
7) Press the [
ENTER] key
Section Description
Zone
Definition
Partition
Assignment
Zone Options
[001]
= Zone 01: 1 2 3 4 5 6 7 8
[002]
= Zone 02: 1 2 3 4 5 6 7 8
[003]
= Zone 03: 1 2 3 4 5 6 7 8
[004]
= Zone 04: 1 2 3 4 5 6 7 8
[005]
= Zone 05: 1 2 3 4 5 6 7 8
[006]
= Zone 06: 1 2 3 4 5 6 7 8
[007]
= Zone 07: 1 2 3 4 5 6 7 8
[008]
= Zone 08: 1 2 3 4 5 6 7 8
[009]
= Zone 09: 1 2 3 4 5 6 7 8
[010]
= Zone 10: 1 2 3 4 5 6 7 8
[011]
= Zone 11: 1 2 3 4 5 6 7 8
[012]
= Zone 12: 1 2 3 4 5 6 7 8
[013]
= Zone 13: 1 2 3 4 5 6 7 8
[014]
= Zone 14: 1 2 3 4 5 6 7 8
[015]
= Zone 15: 1 2 3 4 5 6 7 8
Defaults =
Empty Partition 1 1 and 2
ON
[FORCE] key = empty
Zone Definition
Empty -
Zone Disabled
1 -
Entry Delay 1
2 -
Entry Delay 2
3 -
Follow
4 -
Instant
5 -
24Hr Burglary
6 -
24Hr Buzzer
Additional definitions for
on-board terminals:
7 -
Keyswitch
8 -
Fire 24Hr
9 -
Delayed Fire 24Hr
Partition Assignment
Empty -
Zone Disabled
1 -
Partition 1
2 -
Partition 2
3 -
Both Partitions
Zone Options
1 -
Auto Zone Shutdown
2 -
Bypass Enabled
3 -
Stay Zone
4 - 5 -
Zone Alarm Type
off off Audible alarm (steady)
off on Audible alarm (pulsed)
on off Silent alarm
on on Generates a report only
6 -
Intellizone
7 -
Delay alarm transmission
8 -
Force Zone
Keyswitch Options
1 -
off = Maintained
on = Momentary
2 -
off = Regular Arm
on = Stay Arm
Second DigitFirst Digit