System Timers
Section # Decimal Value (000 to 255) Description Default
[050]
___/___/___ x 10 msec. ZONE SPEED (ZONE 1) 600 msec.
[051]
___/___/___ x 10 msec. ZONE SPEED (ZONE 2) 600 msec.
[052]
___/___/___ x 10 msec. ZONE SPEED (ZONE 3) 600 msec.
[053]
___/___/___ x 10 msec. ZONE SPEED (ZONE 4) 600 msec.
[054]
___/___/___ x 10 msec. ZONE SPEED (ZONE 5) 600 msec.
[055]
___/___/___ x 10 msec. ZONE SPEED (ZONE 6) 600 msec.
[056]
___/___/___ x 10 msec. ZONE SPEED (ZONE 7) 600 msec.
[057]
___/___/___ x 10 msec. ZONE SPEED (ZONE 8) 600 msec.
[058]
___/___/___ x 10 msec. ZONE SPEED (ZONE 9) 600 msec.
[059]
___/___/___ x 10 msec. ZONE SPEED (ZONE 10) 600 msec.
[060]
___/___/___ x 10 msec. ZONE SPEED (ZONE 11) 600 msec.
[061]
___/___/___ x 10 msec. ZONE SPEED (ZONE 12) 600 msec.
[062]
___/___/___ x 10 msec. ZONE SPEED (ZONE 13) 600 msec.
[063]
___/___/___ x 10 msec. ZONE SPEED (ZONE 14) 600 msec.
[064]
___/___/___ x 10 msec. ZONE SPEED (ZONE 15) 600 msec.
[065]
FUTURE USE
[066]
___/___/___ seconds (000 = follow Deactivation Event) PGM1 TIMER 5 sec.
[067]
___/___/___ seconds (000 = follow Deactivation Event) PGM2 TIMER 5 sec.
[068]
___/___/___ seconds (000 = follow Deactivation Event) GLOBAL PGM TIMER 5 sec.
[069]
___/___/___ seconds ENTRY DELAY 1 45 sec.
[070]
___/___/___ seconds ENTRY DELAY 2 45 sec.
[071]
___/___/___ seconds EXIT DELAY 1 30 sec.
[072]
___/___/___ seconds EXIT DELAY 2 30 sec.
[073]
___/___/___ minutes (000 = no bell on alarm) BELL CUT-OFF TIMER (PARTITION 1) 4 min.
[074]
___/___/___ minutes (000 = no bell on alarm) BELL CUT-OFF TIMER (PARTITION 2) 4 min.
[075]
___/___/___ x 15 minutes (000 = disabled) NO MOVEMENT TIMER (PARTITION 1) Disabled
[076]
___/___/___ x 15 minutes (000 = disabled) NO MOVEMENT TIMER (PARTITION 2) Disabled
[077]
___/___/___ seconds (minimum 10 sec.) ANSWERING MACHINE OVERRIDE DELAY Disabled
[078]
___/___/___ (000 = no answer, maximum = 15 rings) NUMBER OF RINGS 8 rings
[079]
___/___/___ x 2 sec. (minimum 32 sec.) TLM FAIL TIMER 32 sec.
[080]
___/___/___ seconds DELAY ALARM TRANSMISSION Disabled
[081]
___/___/___ (000 = 16, maximum = 16) MAXIMUM DIALING ATTEMPTS 8 attempts
[082]
___/___/___ seconds DELAY BETWEEN ATTEMPTS 20 sec.
[083]
___/___/___ seconds PAGER DELAY 5 sec.
[084]
___/___/___ seconds (minimum 10 sec.) INTELLIZONE DELAY 48 sec.
[085]
___/___/___ seconds RECENT CLOSING DELAY No delay
[086]
___/___/___ minutes POWER FAILURE REPORT DELAY 15 min.
[087]
___/___/___ days (000 = disabled) AUTO TEST REPORT Disabled
[088]
___/___/___ 000 to 127 = +1 to +127 seconds
128 to 255 = -1 to -127 seconds
CLOCK ADJUST Disabled
[089]
___/___/___ (000 = disabled, maximum = 15) AUTO ZONE SHUTDOWN COUNTER 5
[090]
___/___/___ minutes (000 = disabled) RECYCLE ALARM DELAY Disabled
[091]
___/___/___ (000 = disabled) RECYCLE ALARM COUNTER Disabled
[092]
___/___/___ attempts before locking (000 = disabled) KEYPAD LOCKOUT Disabled
[093]
___/___/___ minutes (000 = disabled) KEYPAD LOCKOUT DELAY Disabled
[094]
___/___/___ seconds (000 = disabled) PANIC LOCKOUT TIMER Disabled
[095] ___/___/___ days (000 = disabled)
CLOSING DELINQUENCY TIMER (PARTITION 1) Disabled
[110]
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
AUTO TEST REPORT (TIME OF DAY) Disabled
[111]
AUTO-ARM TIME (PARTITION 1) Disabled
[112]
AUTO-ARM TIME (PARTITION 2) Disabled