User's Manual

Magellan / Spectra SP 11
No Movement Auto Arming
The alarm system can be programmed to arm the system and/or send a report if no zone activity occurs for a pre-programmed amount of
time. This is a particularly useful feature when supervising an individual with chronic health problems or a person who lives alone. The
system will bypass any open zones.
Disarming & Deactivating an Alarm
To disarm an armed system or an alarm, press [OFF] and enter your [ACCESS CODE]. An entry point, like the front door, will be
programmed with one of two Entry Delay Timers. When an entry point is opened, the keypad will beep until you disarm the system. Your
alarm system will not generate an alarm until this timer elapses. Any user can disarm a partition they have been assigned to, except
users assigned with the Arm Only Option or PGM Only Option.To disarm alarms generated by a Delayed Fire Zone, refer to Fire Alarms
on page 12.
Manual Bypass Programming
Manual Bypass Programming allows you to program the alarm system to ignore (deactivate) specified zones the next time the system is
armed. For example, you may wish to bypass certain zones when workers are renovating part of your establishment. Once the system is
disarmed, the bypass entries are erased. Manual Bypass Programming can also be activated by using One-Touch Bypass Programming
(see the note below). To remove the Bypass feature from a zone, in step 3 enter the zone number again or press [
CLEAR] to erase all
current entries. When zones are bypassed, the [BYP] key will illuminate.
If One-Touch Bypass Programming is enabled, press the [BYP] key for three seconds to enter Bypass Programming.
Press [
ENTER] after step 2 to bypass all open zones. Press [CLEAR] twice to exit without saving. Press [CLEAR] + [ENTER] to delete bypassed zones.
Bypass Recall Feature
After disarming the system, the bypass entries are erased. The Bypass Recall feature reinstates the previous bypass entries saved in
memory. This eliminates the need to manually re-program the bypass entries every time you arm the system.
How do I temporarily disable the Auto-Arm Timer?
1
Press the [] key.
2 Enter [MASTER CODE].
3 Press the [BYP] key. The [BYP] key will flash to indicate you are in the System Options menu.
4 Press key [1] to set partition 1, or press key [2] to set partition 2.
5 Press and hold [SLEEP] to temporarily disable the Auto-Arm Timer.
How do I disarm the system?
For a Stay or Sleep armed system, go to step 2.
1 Enter through a designated entry point (e.g. front door).
2Press [OFF] + enter [ACCESS CODE].
3
If you have access to both partitions (see Partitioning on page 6): Press the key corresponding to the desired partition ([1] or
[2]). For both partitions, press the other key after the confirmation beep.
How do I deactivate an alarm?
Press [OFF] + enter [ACCESS CODE].
How do I bypass zones?
1 Press the [BYP] key.
2 Enter [ACCESS CODE] (see the note below). The [BYP] key will flash.
3
Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the two-digit zone number (e.g.
zone 3 = 03). Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.
4 Press the [ENTER] key to save and exit.
How do I recall bypass entries?
1 Press the [BYP] key.
2 Enter your [ACCESS CODE].
3 Press the [BYP] key.
4 Press the [ENTER] key.