StayD Mode
To Turn On/Off StayD Mode
To turn on StayD mode:
[STAY] + [CODE] + [STAY] StayD light on
Press the [
STAY] key followed by a valid code, then press the [STAY] key again within ten seconds. The StayD light will light up to confirm
StayD activation, and the system will be in Stay mode.
To turn off StayD mode:
[OFF] + [CODE] + [OFF] Off light on
Press the [OFF] key followed by a valid code, then press the [OFF] key again within ten seconds. The StayD light will turn off and the Off
light will light up to confirm StayD deactivation. With StayD disabled, the system will function as a standard security system.
To Change Arm Mode
To change the level of security - Stay to Sleep:
[SLEEP] for 2 sec. Delay Sleep light on
Press and hold the [
SLEEP] key on any keypad. All zones which will be armed in Sleep mode go into exit delay, allowing you to move to
the bedroom. When the exit delay ends, and you are in the bedroom, the rest of the interior will arm. The system is now in Sleep mode.
To change the level of security - Sleep to Stay:
[STAY] for 2 sec. Stay light on
Press and hold the [STAY] key on the keypad located in the bedroom. The system will instantly switch from Sleep to Stay mode, allowing
you to leave the bedroom and move freely inside the house. If you accidentally leave the bedroom without switching to Stay mode, all
zones armed in Sleep mode will go into a delay, allowing you enough time to switch to Stay mode.
Leaving the site - Stay to Full:
Keypad: [ARM] for 2 sec. Delay Arm light on
Remote: on remote
Press and hold the [
ARM] key on the keypad that the exit path is assigned to. This will start an exit delay period for all zones in the exit
path. After you have left the property, all exit path zones will rearm. The system is now in Full mode.
Entering the site - Full to Stay:
Keypad: [CODE] Stay light on
Remote: on remote
When entering the property through the entry path, all zones assigned to the entry path will go into delay, allowing you to enter the house.
Entering a valid code on the keypad the entry path is assigned to ends the entry delay and switches the system to Stay Arm mode. The
entry path zones will rearm. The system is now in Stay mode.
Leaving the site without changing arm mode:
[OFF] for 2 sec.
Press and hold the [
OFF] key for 2 seconds on a keypad to leave the site without changing arm mode.
Advanced StayD Settings
Window Mode and Re-arm Delay
In a Stay-armed system: This mode allows you to open one exterior zone without triggering an alarm. To enter Window mode, press
[
OFF], then your [ACCESS CODE]. All zones that can be opened flash. The system will start an exit delay, allowing you to open an exterior
zone such as a window or a door. The system will only allow you to open one zone as the exit delay will end after doing so. When you
close the open zone (window, door, etc.) that zone will re-arm.
When closing an exterior zone such as a window or door, a delay will start allowing you to close the zone properly. The re-arm delay
starts when you close the zone, and you must keep the zone closed for the entire delay period for it to re-arm. This is especially useful for
windows that stick thus reducing false alarms.
Live View Mode:
During an alarm, press the [CLEAR] key to view the movement. The zone lights on the keypad will show the opening and closing of zones