User's Manual

26 Programming Guide
Connecting Magellan to WinLoad
Figure 14: Connecting Magellan to WinLoad
Connecting a Paradox Memory Key (PMC-4)
Figure 15: Connecting a Paradox Memory Key (PMC-4)
Back view of the
Magellan console.
Computer
containing
WinLoad
software
4- to 10-pin cable
(supplied with the
306 Adapter)
306
Adapter
4-pin
connector
cable
Standard
DB-9 cable
(9-pin serial
cable)
Back view of the
Magellan console.
Jumper ON:
Read from and/or write to memory key
Jumper OFF:
Write protected (Read from the memory key
only)
PMC-4
Download Data to Destination Console
To download the data of a memory key into a console:
1. Remove power from the Magellan console (AC and battery) and
connect the memory key to the 5-pin connector on the left side of the
back of the console as shown above.
2. Re-apply both AC and battery power to the console.
3. Press the [
OK] key and Magellan will begin downloading the data from
the memory key.
Copy Data to Memory Key from Source Console
To copy the contents of a console into the memory key.
1. Remove power from the Magellan console (AC and battery) and
connect the memory key to the 5-pin connector on the left side of the
back of the console as shown above. Re-apply both AC and battery
power to the console.
2. Press the [
NEXT] key and then the [OK] key. Magellan will begin
copying its data into the memory key.
The installer code of the Magellan console used to
download data to
the memory key must be the same
installer code programmed in the Magellan console that is
to download the contents from
the same memory key. If the
installer codes do not match, the contents of the memory
key cannot be downloaded into the receiving console.
Example: The contents of the Magellan console A will be
copied into memory key B. The installer code for console A
is 111111. In order to download the contents of memory key
B into the Magellan console C, the installer code
programmed in console C must also be 111111.