User's Manual

6 Programming Guide
System Timers
** 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4;
007 = Radio tuner (MG-6160 only)
On-board Programmable Outputs (PGMs)
Refer to Appendix 1: PGM Event Table on page 18 for the PGM events that can be used to program Magellan’s PGM outputs.
Section Data (value from 000 to 255) Description Defaults
[060]
____/____/____ seconds
Entry delay 1 ( )
045 secs.
[061]
____/____/____ seconds
Entry delay 2 ( )
045 secs.
[062]
____/____/____ seconds
Exit delay ( )
060 secs.
[063]
____/____/____ minutes
Bell cut-off time ( ) *
004 mins.
[064]
____/____/____ x 15 minutes
No movement time Disabled
[065]
____/____/____ seconds (minimum 10 seconds)
Intellizone delay 045 secs.
[066]
____/____/____ seconds
Recent closing delay Disabled
[067]
____/____/____ times
Auto-zone shutdown 005 times
[068]
____/____/____ seconds
PGM1 timer Disabled
[069]
____/____/____ seconds
PGM2 timer Disabled
[070]
____/____/____ minutes
Power failure report delay 015 mins.
[071]
____/____/____ days
Auto-test report Disabled
[072]
____/____/____ rings
Number of rings 008 rings
[073]
____/____/____ seconds
TLM fail timer 032 secs.
[074]
____/____/____ seconds
Answering machine override delay 030 secs.
[075]
____/____/____ seconds
Delay alarm transmission Disabled
[076]
____/____/____ seconds (maximum 130 seconds)
Delay between dialing attempts
V
020 secs.
[077]
____/____/____ seconds
Pager/voice delay 005 secs.
[078]
____/____/____ seconds
Remote panic disarm lock delay 020 secs.
[079]
____/____/____ repetitions (maximum 10 repetitions)
Voice reporting message repetitions 003 reps.
[080]
____/____/____ days
Closing delinquency delay Disabled
[081]
____/____/____ (000 to 007**)
Entry delay audio selection ()
003
[082]
____/____/____ (000 to 007**)
Exit delay audio selection ()
002
[083]
Future use
Future use Future use
[084]
____/____:____/____ Hours
Auto-test report time Disabled
[085]
____/____:____/____ Hours
Auto-arm time ()
Disabled
Section Description Event Group # Sub-group # Default
[086]
PGM1 Activation Event
(____/____) (____/____) No event programmed
[087]
PGM1 Deactivation Event
(____/____) (____/____) No event programmed
[088]
PGM2 Activation Event
(____/____) (____/____) No event programmed
[089]
PGM2 Deactivation Event
(____/____) (____/____) No event programmed
J[4] J[4]
J[4] J[4]
J[4] J[4]
J[4] J[4]
J[4] J[4]
J[4] J[4]
J[8] J[3]
* For UL installations, the Bell cut-off time must be a minimum of 4 minutes; for
cUL installations, the Bell cut-off time must be a minimum of 5 minutes.
V
For UL installations, the number of dialing attempts shall not exceed 10.
† For UL installations, the Entry delay must not exceed 45 seconds.