User's Manual
Table Of Contents
- Programming
- To Program Using a Keypad
- To Program Using BabyWare
- 1. Open BabyWare and connected to your system.
- 2. Go to BabyWare => Add Item => Wireless Sirens.
- 3. Fill-in the label, location, and serial number of the SR130.
- 4. Click Save.
- Certifications
- SR130: Outdoor Wireless Siren w/Built-In Strobe Light
- Description
- Overview
- 1. Siren (100dB or more) *
- 2. Wall tamper switch and cover tamper switch
- 3. Reset/Training switch
- 4. Tamper Switch connector
- 5. Battery pack (3 size “C” alkaline batteries)
- 6. Strobe lights
- 7. In-Field connector
- 8. Signal Strength and transmission LED
- 9. Antenna
- 10. Status LED
- 11. Mounting screw
- 12. Captive screw
- LED Feedback
- Installation
- 1. Write down the serial number (on the back of the unit) and location of the SR130 for later reference, to insert into BabyWare.
- 2. Unlock the top cover by turning the captive screw.
- 3. Remove the top cover from the siren.
- 4. Mount the SR130 siren to the wall using the mounting screws.
- 5. Make sure the Anti-Tamper switch is screwed into the wall.
- Siren with Batteries
- Siren without Batteries
- Upgrading Firmware
- Tamper Supervision
- Specifications
- Compatibility
- Warranty
Programming
The following provides instructions on how to program your siren via a keypad or by using BabyWare. For
more details on how to program, please refer to the MG/SP Programming Guide.
To Program Using a Keypad
To Program Using BabyWare
1. Open BabyWare and connected to your system.
2. Go to BabyWare => Add Item => Wireless Sirens.
3. Fill-in the label, location, and serial number of the SR130.
4. Click Save.
Certifications
SR130: Outdoor Wireless Siren w/Built-In Strobe Light
Description
The SR130 is a stand-alone, fully supervised outdoor wireless siren with built-in strobe light and wireless
transceiver. With normal use, the SR130 will function up to three years without the need to replace the
batteries. The SR130 uses 2-way wireless communication, which provides continuous supervision between
the panel and siren with fast response to alarm signals within 4 seconds.The SR130 operates using three
size “C” alkaline batteries.
Overview
Figure 1:ISR130 Back cover
MG6250 MG/SP Feature Details
[0801] [683] Learn Siren #1 Press and hold “Reset/Training” switch for 3 seconds
after entering the section to learn the siren.
WARNING: When you press the "Reset/Training"
switch, the SR130 will squawk and the strobe light
will flash five times to confirm registration to the
panel.
[0802] [684] Learn Siren #2
[0803] [685] Learn Siren #3
[0804] [686] Learn Siren #4
[0801] [687] Display Signal
Strength Siren #1
Press and hold "Reset/Training" switch for 3 seconds
after entering the section to display, on a K32LCD
V1.3 or higher, the signal strength the panel is
receiving from the siren.
[0802] [688] Display Signal
Strength Siren #2
[0803] [689] Display Signal
Strength Siren #3
[0804] [690] Display Signal
Strength Siren #4
[0811] [691] Label Siren #1 These labels are used when reporting events via
e-mail through the IP100/ IP150 (MG/SP only) or
SMS personal reporting (MG6250 only) and for
troubleshooting purposes. Maximum 16 characters.
[0812] [692] Label Siren #2
[0813] [693] Label Siren #3
[0814] [694] Label Siren #4
[0800] [695] Temporary
Tamper Switch
Deactivation for
Maintenance
Press the [enter] key after entering the section to
deactivate tamper alarm until the cover is
reinstalled or after 30 minutes.
[0820] [587] Panel
Supervision of
Siren
OFF = disabled ON = enabled (default)
Option [1] Option [3] Siren #1 (OFF/
ON)
The control panel supervises the presence of the
SR130. If lost, the control panel will follow global
supervision loss option set in the panel.
Option [2] Option [4] Siren #2 (OFF/
ON)
Option [3] Option [5] Siren #3 (OFF/
ON)
Option [4] Option [6] Siren #4 (OFF/
ON)
EN50131-4 Grade 2, Type W EN 50130-5 Class IV
Certification
Body:
Applica Test and Certification
DESIGN
SR120 Outdoor
1. Siren (100dB or more) *
2. Wall tamper switch and cover tamper
switch
3. Reset/Training switch
4. Tamper Switch connector
5. Battery pack (3 size “C” alkaline batteries)
6. Strobe lights
7. In-Field connector
8. Signal Strength and transmission LED
9. Antenna
10. Status LED
11. Mounting screw
12. Captive screw
* Warning! High Voltage. Remove batteries
before maintenance
SR130-EI00
Version 1.0
Printed in Canada
12/2014