Table A-14. SNMP Traps Options (1 of 2)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Controls the generation of SNMP trap messages.
Enable SNMP trap messages are sent out to SNMP managers.
Disable No SNMP trap messages are sent out.
Number of Trap Managers
Possible Settings: 1, 2, 3, 4, 5, 6, 7, 8, 9
Default Setting: 1
Sets the number of SNMP management systems that will receive SNMP traps.
H This field is not available when the unit is running in IP Conservative mode.
1 to 9 Number of trap managers. An NMS IP address is required for each manager.
NMS n IP Address
Possible Settings: 001.000.000.000 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the Internet Protocol address used to identify each SNMP trap manager.
H This field is not available when the unit is running in IP Conservative mode.
001.000.000.000 223.255.255.255 Enter an address for each SNMP trap manager.
The range for the first byte is 001 to 223, with the exception of 127. The range for the
remaining three bytes is 000 to 255.
Clear Clears the IP address and sets to all zeros.
NMS n Destination
Possible Settings: IMC, DSL1, DSL2, DSL3, DSL4, DSL5, DSL6, DSL7, DSL8
Default Setting: IMC
Provides the network destination path of each trap manager.
H NMS n Destination is available only when the unit is configured as an NTU and not
running in IP Conservative mode. Disabled ports cannot be specified.
IMC The Internal Management Channel (IMC) is the default network destination. This
is the management interface to the MCC card in the DSLAM.
DSL1 to DSL8 The specified port is the network destination.
General Traps
Possible Settings: Disable, Warm, AuthFail, Both
Default Setting: Both
Determines which SNMP traps are sent to each trap manager.
Disable No general trap messages are sent.
Warm Sends trap message for warmStart events.
AuthFail Sends trap message for authenticationFailure events.
Both Sends both trap messages.
NOTE: Refer to Appendix B, Standards Compliance for SNMP Traps.