Network Hardware User Manual

Monitoring and Troubleshooting
7-16
8700-A2-GB20-00
April 2000
H BES (Bursty Errored Seconds): Contains the number of bursty errored
seconds for the current interval. A bursty errored second is any second with
more than one but less than 805 CRC errors (CRC Mode) or more than one
but less than 16 FAS errors (non-CRC mode).
H CSS (Controlled Slip Seconds): Seconds during which one or more
controlled slips (as defined in TR 54016) occurred.
H LOF (Loss of Frame Seconds): Contains the number of seconds that
contain one or more LOF events.
H Status: Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
Y: Remote alarm indication signal received at the G.703 interface
L: Loss of signal detected at the G.703 interface
E: Excessive error rate threshold exceeded
F: Frame synchronization bit error detected
V: Line code violation detected
None: No significant events have occurred
Use the virtual function keys to page through the intervals and clear statistics.
This Field . . .
Contains . . .
Current Interval
Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter is reset every 15 minutes.
Error Events
Counter
A running total of CRC errors. Range 065535. This counter is
reset when the statistics are cleared.
Current Int Performance data for the current 15-minute interval.
Interval xx Historical performance data for up to 96 15-minute intervals
(24 hours).
Worst Interval The number of the interval with the worst (highest) performance
data statistics. If two or more intervals are equal, the oldest
interval is displayed.
Tot A running total of the performance statistics.