Manual
Table Of Contents
- Contents
- About This Guide
- 1. About the FrameSaver SLV
- 2. User Interface and Basic Operation
- 3. Configuration Procedures
- 4. Configuration Options
- Using the Easy Install Feature
- Using RIP with FrameSaver SLV CSU/DSUs
- Entering System Information and Setting the System Clock
- Setting Up the Modem
- Setting Up Auto-Configuration
- Setting Up Dial Backup
- PVC Backup Over the Network Interface
- Setting Up Back-to-Back Operation
- Configuration Option Tables
- Configuring the Overall System
- Configuring Physical Interfaces
- Assigning Time Slots/Cross Connections
- Configuring Frame Relay for an Interface
- Manually Configuring DLCI Records
- Configuring PVC Connections
- Configuring the IP Path List
- Setting Up Management and Communication Options
- Configuring the Criteria for Automatic Backup
- 5. Configuring the FrameSaver SLV Router
- FrameSaver SLV Router Overview
- IP Routing
- Address Resolution Protocol
- Proxy ARP
- Interface Configuration
- Network Address Translation
- Network Address Port Translation
- Dynamic Host Configuration Protocol Server
- DHCP Relay Agent
- Router Security
- Provisioning the Router Interface
- Configuring the Router Using Terminal Emulation
- 6. Security and Logins
- 7. Operation and Maintenance
- 8. Troubleshooting
- 9. Setting Up OpenLane for FrameSaver Devices and Activating SLM Features
- 10. Setting Up NetScout Manager Plus for FrameSaver Devices
- 11. Setting Up Network Health for FrameSaver Devices
- A. Menu Hierarchy
- B. SNMP MIBs and Traps, and RMON Alarm Defaults
- C. Router CLI Commands, Codes, and Designations
- D. Router Command Line Summaries and Shortcuts
- E. Connectors, Cables, and Pin Assignments
- F. Technical Specifications
- G. Equipment List
- Index

7. Operation and Maintenance
7-52
September 2002 9128-A2-GB20-80
Service Level Verification Performance Statistics
These statistics appear when Service Level Verification (SLV) is selected from the
Performance Statistics menu.
Main Menu
→
Status
→
Performance Statistics
→
Service Level Verification
They only appear for the network interface and only if DLCIs are multiplexed or IP
Enabled.
Information displayed on the SLV Performance Statistics screen depends on DLCI
type. See Table 7-16, SLV Performance Statistics for Multiplexed DLCI or
Table 7-17, SLV Performance Statistics for IP Enabled DLCI.
On either screen, select P
revDLCI or NextDLCI to view statistics for the previous
or next DLCI on the link. On the IP Enabled DLCI screen, select Prev
Path or
Nex
tPath to view statistics for the previous or next path associated with the DLCI.
For standard or multiplexed DLCIs, the statistics collected by the unit depend upon
the device at the far end of the connection. If the far-end device is a FrameSaver
SLV unit, frame relay, latency, and FDR/DDR performance statistics are collected.
The Frame Relay Delivery Ratio is the number of delivered frames/offered frames;
the Data Delivery Ratio is the number of delivered octets/offered octets.
If the far-end device is a non-FrameSaver device, or a FrameSaver 9120 or 9620,
only frame relay statistics are collected.
Table 7-16. SLV Performance Statistics for Multiplexed DLCI (1 of 3)
Statistic What It Indicates
Far End Circuit Number of the multiplexed DLCI or VPI/VCI (Virtual Path
Identifier/Virtual Channel Identifier) at the other end of the
connection.
If the far-end circuit is a DLCI, the DLCI number (16–1007)
appears. If a VPI/VCI, the number is displayed as
xx,yyy,
xx
being the VPI number (0 –15) and
yyy
being the VCI number
(32–2047).
None
appears if the unit has not communicated with the other
end.
Far End IP Addr IP Address of the device at the other end of the multiplexed
DLCI connection.
None
appears if the FrameSaver unit has not communicated
with the other end, or if the device at the other end of the
multiplexed DLCI does not have an IP Address configured.
Dropped SLV
Responses
The number of SLV inband sample messages sent for which a
response from the far-end device has not been received.
* Only appears for FrameSaver units when the SLV Delivery Ratio option is
enabled.