Manual
Table Of Contents
- Contents
- About This Guide
- 1. About the FrameSaver SLV
- 2. User Interface and Basic Operation
- 3. Configuration Procedures
- 4. Configuration Options
- Using the Easy Install Feature
- Using RIP with FrameSaver SLV CSU/DSUs
- Entering System Information and Setting the System Clock
- Setting Up the Modem
- Setting Up Auto-Configuration
- Setting Up Dial Backup
- PVC Backup Over the Network Interface
- Setting Up Back-to-Back Operation
- Configuration Option Tables
- Configuring the Overall System
- Configuring Physical Interfaces
- Assigning Time Slots/Cross Connections
- Configuring Frame Relay for an Interface
- Manually Configuring DLCI Records
- Configuring PVC Connections
- Configuring the IP Path List
- Setting Up Management and Communication Options
- Configuring the Criteria for Automatic Backup
- 5. Configuring the FrameSaver SLV Router
- FrameSaver SLV Router Overview
- IP Routing
- Address Resolution Protocol
- Proxy ARP
- Interface Configuration
- Network Address Translation
- Network Address Port Translation
- Dynamic Host Configuration Protocol Server
- DHCP Relay Agent
- Router Security
- Provisioning the Router Interface
- Configuring the Router Using Terminal Emulation
- 6. Security and Logins
- 7. Operation and Maintenance
- 8. Troubleshooting
- 9. Setting Up OpenLane for FrameSaver Devices and Activating SLM Features
- 10. Setting Up NetScout Manager Plus for FrameSaver Devices
- 11. Setting Up Network Health for FrameSaver Devices
- A. Menu Hierarchy
- B. SNMP MIBs and Traps, and RMON Alarm Defaults
- C. Router CLI Commands, Codes, and Designations
- D. Router Command Line Summaries and Shortcuts
- E. Connectors, Cables, and Pin Assignments
- F. Technical Specifications
- G. Equipment List
- Index

1. About the FrameSaver SLV
1-12
September 2002 9128-A2-GB20-80
NetScout Manager Plus and NetScout Probes
Provides complete LAN and WAN traffic analysis and monitoring functions for
FrameSaver devices.
The following features are supported using this application:
Thresholds for RMON 1 (Remote Monitoring, Version 1) alarms and events
can be configured.
Performance monitoring can be performed using collected RMON 2
(Version 2) data. NetScout Manager Plus’s Protocol Directory and Distribution
functionality allows FrameSaver devices to measure up to eleven
network-layer protocols and report the amount of traffic generated by each. Its
IP Top Talkers and Listeners reporting identifies the devices using network
bandwidth for traffic and protocol analysis, identifying the network’s top six
users. In addition, it collects performance statistics from FrameSaver devices.
Up to 900 samples can be stored in 15-minute buckets, with 96 buckets in a
24-hour period, for up to five days worth of data.
Optional standalone NetScout Probes can be used with FrameSaver devices
at sites where full 7-layer monitoring, an unlimited number of protocols, and
advanced frame capture and decode capabilities are desired.