2000
User Port Settings
Data Rate - Displays the data rate for the User Circuit which results from the
settings for DS0 Assignments and the DS0 Format.
4. DS0 Format - Selects 56K or 64K mode for all the DS0s in the User Circuit.
5. Port TxD Clk - Configures the User Port interface to clock in the Tx data based
on either the DCE (this units) supplied clock, or the DTE (cable loop or router)
supplied clock.
Network Port Settings
6. Facility ID - Enter alphanumeric string to identify facility on other screens.
7. Build Out - Selects the Line Build-Out value for the T1 line connection.
8. Framing - Selects T1 Framing format to be used.
NOTE: ANSI or AT&T are ESF format, SF includes D4.
9. Ones Dens - Selects the Ones Density format to be used.
10.Clock Source - Defines which clock source is used for internal FrameSaver NP
timing.
11.Link Err Thres - Disables or sets the threshold for the CSU Threshold Alarm. An
alarm is declared when the Near End - Errored Seconds plus Unavailable Seconds
equals or exceeds the threshold in the current 15-minute interval.
Commands
Help [?] - Advances to Help for CSU / DTE Configuration screen.
Save [SA] - Saves parameters and returns to System View screen.
Cancel [X] - Returns to System View screen without saving changes.
Save the CSU / Interface Configuration changes when they are all set correctly by en-
tering SA followed by ENTER. This will also return the user to the System View
screen.
Proceed to Frame Manager Configuration, selecting [FC] by typing FC followed
by ENTER.