Brochure

4374
Defrost Controls, Timers & Monitors
Defrost Controls
Nos. 5X454 to 5X456 are CSA Certified. No.
1TGD6 is UL873 NSF Certified.
TIMERS FOR WATER SPRAY DEFROST CONTROL
WITH PUMP-DOWN DRAIN OR FAN DELAY CYCLES
Defrost initiation: 1 to 8 cycles per day, at least 3
hrs. between cycles. Delay or pump-down cycles:
0 to 30 min. in 3-min. increments; for stopping
fans, reducing refrigerant pressure, or hot gas
pump-down cycle. Defrost cycles: 3 to 45 min.
in 3-min. increments. Drain or fan cycles: 3 to 15
min. in 3-min. increments.
No. 5X450
* NO=Normally Open; NC=Normally Closed.
Voltage
Contact
Type* Amps
Mfr.
Model
Item
No.
$
Each
Timers for Water Spray Defrost Control with Pump Down Drain or
Fan Delay Cycles
120 2 NO,2 NC 10 632-00 5X450
359.75
208/240 2 NO,2 NC 10 632-20 5X451
369.00
Time-Initiated and Time-Terminated Defrost Controls
120 SPDT 40 8045-0 5X454
184.75
208/240 SPDT 40 8045-20 5X455
193.00
208/240 2 NO,1 NC 40 8047-20 5X456
207.75
Time-Initiated, Remote-Temperature, or Pressure-Terminated
Defrost Controls
120 1 NO,2 NC 40 8141-0 5X457
213.25
120 SPDT 40 8145-0 5X458
201.00
208/240 SPDT 40 8145-20 5X459
185.50
Time-Initiated, Pressure-Terminated Defrost Controls
208/240 SPDT 40 8245-20 5X460
384.25
Universal Defrost Timer
120/208/240
1 SPDT, 1
SPST
30 9145-00 1TGD6
204.75
TIME-INITIATED AND TIME-TERMINATED
DEFROST CONTROLS
Choice of 4 contact arrangements for electric
heat, hot gas, or compressor shutdown defrost.
Defrost/initiation cycles: 1 to 6 per day, at least
4 hr. between operations. Dial overlay changes
defrost time from even- to odd-numbered
hours. Defrost cycles: 4 to 110 min. in 2-min.
increments. Case has heavy steel enclosure
with padlock hasp.
TIME-INITIATED, REMOTE-TEMPERATURE, OR
PRESSURE-TERMINATED DEFROST CONTROLS
Work with external temperature or pressure
sensor. Choice of 3 contact arrangements for
electric heat, compressor shutdown, or hot gas
defrost. Defrost cycles: 1 to 6 per day, at least 4
hr. between cycles. Dial overlay changes defrost
time from even- to odd-numbered hours.
Backup defrost termination: 4 to 110 min. in
2-min. increments. Case has heavy steel enclo-
sure with padlock hasp.
TIME-INITIATED, PRESSURE-TERMINATED
DEFROST CONTROLS
Direct readout dial. Modular pressure bellows.
3 contact arrangements for hot gas, electric
heat, or compressor shutdown defrost. Defrost
cycles: 1 to 6 per day, at least 4 hr. between
cycles. Dial overlay changes defrost time from
even- to odd-numbered hours. Backup defrost
termination: 4 to 110 min. in 2-min. increments.
Adjustable cut-in pressure-setting dial calibrated
from 36 to 100 lb. Case has heavy steel enclosure.
UNIVERSAL DEFROST TIMER
Multivoltage timer is easy to program with time and
defrost start/finish. Manual defrost can be initiated
in 15-min. intervals. Fits standard Paragon enclo-
sures. Provides 100 hr. of power loss protection.
System status indicators and lighted display.
3-Phase Line Voltage Monitors
Independently monitor voltage imbalance, high/
low voltage, phase loss, reversal, incorrect
sequencing, and rapid short cycling. UL Listed
and CSA Certified.
No.
3UW93
* Physical dimensions vary by manufacturer.
Cross-Reference*
Includes
Volts
50/60 Hz
% Volts
Unbalance
Control
Volts (AC)
N.O. Output
(A)
NC Output
(A)
Diversified
Model
Motorsaver
Model
SSAC
Model
TimeMark
Model
Wagner
Model
Watsco
Model
Mfr.
Model
Item
No.
$
Each
LCD Display 190-630 2 to 25, Adj. 18 to 240 10 6 AC-2020AC-
455 QLM/QLV 265 WPC-800
EAC-800 ICM450 3UW93
266.25
LED Display 190-630 2 to 25, Adj. 18 to 240 20 10 301AC-302 EAC-8000 ICM400 3UW89
205.50
LCD
Programmable 25-fault memory storage. Independent
high/low voltage settings. Programmable line voltage,
manual or automatic reset, push-button setup.
LED DISPLAY
Knob-adjustable features.
Refrigeration Defrost Thermostats
Moisture-resistant thermostats can be used as
exact OEM replacements for most refrigerators
and icemakers. Short trim is ideal for reaching
into tight places. SPDT switch opens on rise.
120/240V.
No. 2FBY5
Switch
Type
Switch
Amp
Rating
Temp.
Range (°F) Diff.
Switch
Opens
@ (°F)
Switch
Closes
@ (°F)
Mfr.
Model
Item
No.
$
Each
SPDT 25 55 to 35 20 55 35 SL5709 2FBY5
54.50
SPST 10 80 to 30 50 ±4°F 80 30 ML80 3CHK2 7.45
Refrigeration/Defrost Control
Microprocessor-based controller manages all temperature and defrost
functions in a typical piece of commercial refrigeration equipment,
replacing up to 5 controls. Features 2 NSF-approved temperature
sensors for the case and the evaporator, and 4 relay outputs for
compressor, fan, defrost, and alarm. Line voltage input power is select-
able 120/208/240VAC at 50/60 Hz, enabling use on a wide range of
equipment. UL873 NSF Certified. Replacement sensor includes 10-ft.
cable. Sensor can be expanded to 100 ft. using additional 18-ga.
shielded cable. For use with electric, hot gas, or timed-off defrost appli-
cations controls.
No. 1TGD4
Item
Switch
Type
Control
Range
(°F)
Temp.
Differential (F)
Brand
Mfr.
Model
Item
No.
$
EachHigh Low
Refrigeration/
Defrost Control
4 SPDT -40 to 60 25 1 Paragon
ERC2-
212111-370
1TGD4
268.75
Item For Use With Brand
Mfr.
Model
Item
No.
$
Each
Mounting Bracket
1TGD4, ERC2
Series Sensors
Ranco 1397002-045 1TGD5 3.80
Replacement Sensor 1TGD4 Paragon 1309007-045 5PWD7 19.68
Residential
Defrost Timers
Direct replacements
for defrost timers in
household refrigera-
tors and freezers. No
drilling, tapping, or
adapter plugs needed.
10A noninductive,
1
3
HP, 120VAC.
Limited availability.
No. 6X629
* Direct replacement for JE-539 and A-769.
† Direct replacement for NE-539 and F-769.
‡ Direct replacement for NA-539 and G-769.
Max.
On/Off
Cycles
Defrost
Time
(Minutes)
Mfr.
Model
Item
No.
$
Each
6 21 E-1111* 6X629 24.04
8 20 D-1111** 6X630 24.53
8 21 E769-00 6X631 27.95
6 25 A-1111† 6X632 23.00
6 25 B-1111‡ 6X633 24.53
8 21 E931-00 4E057 25.05
8 30 D-769-00 6X869 27.25