User's Manual

Sistema FIREMASTER III "Millennium" Manuale di istruzioni
20
NOTE: when the "WARNING" icon appears, the system can be still
used as usually. One should anyway consider as the system is working near to
the lower limit of its possibilities and thus some problems more or less severe
could be encountered such as: firing failures, no response from the Remote
Unit, errors reading data, etc. Using the system when the "WARNING"
signal is ON, is fully under the responsibility of the operator: he must evaluate
if the show importance is worth the risk of operating near to the safety limits.
IN ALL CASES THE SYSTEM ALWAYS GRANTS A SAFE
OPERATION AGAINST UNDUE OR PREMATURE FIRINGS.
3) The selected Remote Unit ANSWERS and data are displayed on the screen.
The selected line is connected to a series of 10 squibs with a total resistance
(squibs + cables) of 27 ohm, the SEQUENCE for that line is a timed one with
a delay of 12 seconds and 35 hundredths of second. Data will appear as
follows:
When a Remote Unit transmits back data and the situation is similar to the one
depicted at point (2) or (3), the operator can simply read the data values (if the
query was made just to make a CONTROL), or he can take the suitable actions if
some parameter should fall outside the acceptable limits, such as: recharge or
replace the Battery Pack if the read voltages are too low, replace the antenna or vary
the position of the Remote Unit attempting to increase a weak radio signal, or