passed, OK: the battery was just discharged and can be still used.
If otherwise the battery still exhibits an excessive voltage
reduction under load, then it MUST BE IMPERATIVELY
DISCARDED AND REPLACED WITH A NEW ONE.
NOTE: all batteries installed inside the RX48 Units, are
AUTOMATICALLY TESTED with the above method.
7) The MEAN LIFE of a lead-acid battery is ABOUT 2 YEARS or
500 charging cycles (whichever is less). It is thus suggested, in a
prudential way, to CHECK YEARLY with great care all batteries
and to replace all devices giving test results LESS THAN
PERFECT (even if apparently acceptable). The recovered
batteries, if still passing the load test, can be used as
EMERGENCY EXTERNAL BATTERIES.
8)
, We recall here the RECYCLING RULES concerning
the battery disposal: it must absolutely avoided to dispose the
failed batteries with the common garbage, call instead a
specialized collecting center enabled for the recycling of this
polluting waste!