User's Manual

FIREMASTER IV "
MillenniumThree
" radio shooting system User’s manual
This mask is also AUTOMATICALLY displayed when the TX5000 Base
Station has finished with the remote programming and one or more
problems have been encountered.
2.5.2 ERROR MESSAGES
The following error messages can be displayed in the SHOW VERIFY mask.
E.g.:
UNIT ERROR TYPE
(1) 12 Not PROGRAMMED
(2) 12 Line(s) OPEN
(3) 12 No response
(4) 12 Program Error
1) One or more lines of the Remote Unit results NOT PROGRAMMED
with consistent data
2) One or more lines, while correctly programmed, result as OPEN
CIRCUIT
3) The Remote Unit doesn’t respond. The TX5000 base Unit makes two
successive attempts.
4) The data sent back by the Remote Unit (relative to one or more lines)
doesn’t match the show program stored in memory by the base Unit
TX5000
Each message type is displayed only once even if more lines have the same error
The error list has a maximum lenght of 14 items.
No specific indication is given about the lines in error: the purpose of this
function is just to check if there complete match between the data stored inside
the Remote Units and the show data hold in memory by the TX5000 base Unit.