User's Manual

FIREMASTER IV "
MillenniumThree
" radio shooting system User’s manual
RS-232 CONNECTOR – TX5000
Connector type: DIN, circular, female, 7 poles.
1) +5Vd.c. (for programming purposes only)
2) TX data
3) RX data
4) MD1 (for programming purposes only)
5) COMMON
6) RESET (for programming purposes only)
7) SHIELD
RS-232 CONNECTOR – RX48
Connector type: DIN, circular, female, 12 poles.
A) MD1 section “B” (for programming purposes only)
B) AUX section “B” (not implemented)
C) RX data section “A”
D) TX data section “A”
E) MD1 section “A” (for programming purposes only)
F) COMMON
G) AUX section “A” (not implemented)
H) RESET section “A” (for programming purposes only)
J) RX data section “B”
K) TX data section “B”
L) RESET section “B” (for programming purposes only)
M) COMMON
WARNING: all pins marked in RED, are RESERVED for programming
purposes and must be left UNCONNECTED.
79