User's Manual

FIREMASTER IV "
MillenniumThree
" radio shooting system User’s manual
(steady) if the relative battery doesn’t pass the initial test or the charging
process is terminated with a FAULT condition.
16. zz BATTERY 1 – SYSTEM (red/green). This bi-color indicator LED
blinks GREEN during the normal charging process and turns ON RED
(steady) if the relative battery doesn’t pass the initial test or the charging
process is terminated with a FAULT condition.
17. z RX SAFE green LED. It flashes shortly every time the Unit receives
and decodes a radio signal containing its User's Code (even if the
command was not directed to that particular Unit). It could be used as
status indicator for the correct performance of the RADIO RECEIVER.
18. z RX FIRE red LED it flashes shortly every time the Unit receives a
FIRE COMMAND addressed specifically to it.
19. z TX R.F. blue LED It flashes shortly when the TRANSMITTER of
the Unit is ON (typically when the Unit is answering to a command of
the Base Unit or when it is sending data).
4.4 LED DISPLAYS DESCRIPTION
Each section of the RX48 Units has a 3-digit LED indicator. This display,
during the normal operation, shows permanently the UNIT NUMBER
assigned to the Unit’s section. The Unit numbering can span between 1 and
255: usually the section “A” has ODD numbers (1, 3, 5, 7, etc.), while the
“B” section has EVEN numbers (2, 4, 6, 8, etc.).
This rule however is not mandatory since a new RX48 TWIN UNIT can be
used by a customer ALREADY owning one or more FIREMASTER III
RX24 units. In this case the new RX48 units supplied to the customer WILL
FOLLOW the previous numbering in order to avoid “gaps”.
E.g.: imagine a Customer, already owning 4 Units RX24 (Firemaster III)
numbered 1 to 4 and ordering two new RX48 Units (this is equivalent to
purchase FOUR RX24). The new units supplied will be numbered as
follows: one unit will have section “A” assigned as Unit 5 and section “B”
assigned as Unit 6, while the second RX48 will have section “A” assigned
as Unit 7 and section “B” assigned as Unit 8. Of course ALL UNITS
(Firemaster III and Firemaster IV) will have THE SAME USER’S CODE.
This is the NORMAL WAY the units are numbered at factory. Upon
specific request, it is however possible to supply the new RX48 Units with
ANY COMBINATION of section numbering.
The 3-digit LED indicators can display some other messages both during the
initial TEST phase and when a problem or a fault condition is detected. The
possible messages are listed below:
63