User's Manual

FIREMASTER IV "
MillenniumThree
" radio shooting system User’s manual
- TEST tst this messages is issued during the initial test of the firing
lines (every time the Unit is switched ON).
- LINE ERROR F
nn
If a fault should be detected during the line test,
the message “Fnn” will be issued. “
nn
“ is the actual number (1 to 24)
of the line failing to pass the test. The test will stop, the System will
hang-up with this indication permanently displayed. This situation is
NOT RECOVERABLE since the LINE FAILURE is considered a
SEVERE FAILURE capable to produce destructive effects. The
relative section of the RX48 Unit is immediately placed in a SAFE
CONDITION. The Unit must be serviced as soon as possible. If the
remaining section (“A” or “B”) does pass the line test without errors,
then this section can be used safely, while the section with one or more
line failing to pass the test must remain UNUSED with ALL LINES
DISCONNECTED.
- DATA ERROR dAt When CORRUPTED DATA (data relative to
the LINES parameters) are detected in the memory or when the Unit
has been NEVER PROGRAMMED BEFORE (memory blank), the
dAt” message is issued. This condition doesn't forbid the system's
operation: it will be sufficient to "call" the Unit or even any single
line of that Unit and to modify a parameter (e.g.: the SEQUENCE
number). The error condition will be RESET. WARNING!: this
operation doesn't restore other data eventually corrupted. Since
this indication warns about a GENERIC data loss in memory (it could
be relative to one or more data), it will be a good choice to RE-
PROGRAM COMPLETELY THE UNIT.
- BATTERY ERRORS FbS The message is issued when the
SYSTEM BATTERY (12V 5,7Ah) fails to pass the initial test. The
SYSTEM
will remain BLOCKED for the following cases:
The open-circuit of the SYSTEM battery is BELOW 11V
The VARIATION between the OPEN-VOLTAGE and the
measurement UNDER LOAD of the SYSTEM battery is more than
25%
If otherwise the following condition is detected during the SYSTEM battery
test, the UNIT can be used normally but one must take into account as the
batteries are NOT FULLY EFFICIENT and they must be checked and re-
charged as soon as possible. The message is displayed momentarily and at
the same time a long buzzer sound is generated:
The VARIATION between the OPEN-VOLTAGE and the
measurement UNDER LOAD of the SYSTEM battery is more than
15% but NO MORE THAN 25%
- BATTERY ERRORS FbL The message is issued when the LINE
BATTERIES (24V 1,2Ah) fail to pass the initial test. The SYSTEM
will remain BLOCKED for the following cases:
64