User's Manual

T6T VHF 100 W Transmitter Page 2 Operation
Back to Transmitter
Main Page
Controls, Indicators and Front Panel Connectors
This section describes the transmitter’s controls, indicators and front panel connectors.
Front Panel
The transmitter’s front panel is illustrated below.
Scroll/Select Switch and LCD
The Scroll/Select switch is used in conjunction with the LCD to select most of the transmitter's operational
settings. During normal operation, the LCD shows the operating frequency, the channel number (if the
channel store facility is used), the carrier offset (if used), and displays a graphical representation of
instantaneous peak power.
The example LCD screen above shows the transmitter operating on 118.000 MHz; the frequency has
been preset as channel 100 and offset at +7.3 kHz.
Ready Indicator
A green indicator that lights when the transmitter is ready for use and no BIT faults have been detected.
Transmit Indicator
An amber indicator that lights when the transmit circuit is keyed and producing output power.
Alarm Indicator
A red indicator that either flashes, or lights, when a BIT fault has been detected. BIT indications are
classified as either Alarms or Alerts.
If an ‘alert’ condition is detected, the Alarm indicator flashes, the Ready indicator remains lit, and the
transmitter remains operational. A BIT ‘alert’ is indicated if:
The transmitter RF output power has reduced from its setting by more than 1 dB but not more than
3 dB.
The supply volts falls below a pre-defined level.
Any other BIT condition results in an alarm. When detected, the Alarm indicator lights and the Ready
indicator becomes unlit; the transmitter cannot be used.
READY
ALARM
TRANSMIT
STANDBY
SCROLL/
SELECT
MICROPHONE/
DIAGNOSTICS
REFERENCE
F r e q 1 1 8 .0 0 0 M H z
C h 1 0 0 + 7 . 3 k H z
P w r
Scroll/Select SwitchLCD
M o d e A M V o i c e 1