User's Manual

T6T VHF 100 W Transmitter Page 4 Installation
Back to Transmitter
Main Page
Configuration
Connection of external equipment depends on the configuration required. Possible configurations are:
T6T transmitter configured for local operation (see Fig 1).
T6T transmitter configured for remote operation (see Fig 2).
T6T transmitter configured for use with MARC (see Fig 3).
T6T Mode 2 configuration (see Fig 4).
T6T Mode 3 configuration. (see Fig 5).
Fig 1 T6T Transmitter Configured for Local Operation
For local operation, the transmitter is operated from the front panel using a microphone/headset.
Any of the optional facilities may be connected.
Antenna
Connector
Reference
Connector
Microphone/Diagnostics
Connector
Frequency Counter
required only for
maintenance
Facilities
Connector
T6T Transmitter
E-BIT input
PTT relay output
External VSWR input
dc supply output
Inhibit input
BIT interruptive test input
Antenna change-over output
Ready output
Tape output
Optional Facilities that
can be used if required
Laptop (or PC) required
only for maintenance
Mic/Headset for
local operation