User's Manual

31-3MDR00HB Page 39 Installation
Draft
The procedures in this document describe how to install an MDR. The procedures necessary during
installation are listed in Table 8.
Fuses and Connectors
Table 9 lists the radio’s supply fuse and the connectors. Some of the connectors (depending on your
particular configuration) are required during installation.
Initial Inspection of the MDR
On receipt of the MDR from Park Air, remove all transit packaging and check that there is no damage. If
damage is evident, contact Park Air immediately and retain the original transit packaging. It is helpful if
photographs of any damage can be taken and then forwarded to Park Air in support of any claim.
Table 8 Installation Procedures
Procedure Reference
1 Perform an initial inspection of the MDR. page 39
3 Fit the MDR into an equipment cabinet. page 40
4 Connect the remote signals (as required). page 41
5 Connect the chassis stud to the cabinet or system earth. page 46
6 Connect an antenna page 46
7 Checking the ac input fuse page 47
8 Connect the ac supply. page 47
Table 9 Fuses and Connectors
Component Type Park Air Part Number
Fuse:
AC input fuse T4AH 250V IEC 29E01120108S
Connectors:
AC supply connector IEC 20-02030102
Antenna connector N-type plug (straight)
or,
N-type plug (right-angle)
19-01030301
19-01030401
Ethernet connector RJ45 plug 20K01080100
Facilities connector 25-way D-type plug Plug: 20-01250100
Cover: 20-09250101
Auxiliary connector 9-way D-type plug Plug: 20-01090100
Cover: 20-09090101
Reference connector BNC to SMB 2 metre long lead 17K11000004
Diagnostics connector 7-pin DIN plug to 9-way D-type, radio
to PC interconnection lead
17E12600001