User's Manual

31-3MDR00HB Page 50 Maintenance
Draft
Maintenance Policy
Apart from the scheduled maintenance detailed in this topic, and replacing a faulty cooling fan, the
maintenance policy for the MDR is to return faulty units to Park Air.
Unscheduled Maintenance
Unscheduled maintenance is limited to replacing a faulty cooling fan (see page 54).
Scheduled Maintenance
Park Air recommends that scheduled maintenance be carried out at twelve-monthly intervals. Schedule
maintenance comprises:
(1) Ensuring the equipment is clean.
(2) Ensuring that the external connectors are securely fitted to the MDR.
(3) Checking and resetting (if required) the MDR's frequency standard (see page 51).
(4) Performing an interruptive BIT test (see page 52).
Cleaning the Equipment
Remove all dust and dirt from the equipment's exterior using cleaning cloths and a camel hair brush.
Clean the front panel indicators and LCD face.
Security of External Connections
Check all external connections are secure and free from damage.
There are no user serviceable parts within the MDR. Breaking the seals on the
top and bottom covers voids the MDR’s warranty.