BIT Status Warning Screens
The following shows some example BIT screens. These screens alternate with the Main Screen when
an alert or alarm condition is present. Only the parameters causing the alert or alarm are displayed, and
if both an alert and alarm condition exists simultaneously only the alarm information is displayed. If
multiple parameters are signalling an alert or alarm condition, multiple screens are used to display the
status alternating with the Main Screen.
A L E R T
S u p p l y 2 1 V
A L E R T
R F P o w e r R e d u c e d
L o o p E r r o r
S u p p l y 2 1 V
A L E R T
R F P o w e r R e d u c e d
P A T e m p 8 5 d e g C
A L A R M
S y n t h L o c k F a i l
A L A R M
R F P o w e r R e m o v e d
L o o p E r r o r F A I L
S u p p l y 1 8 V
Alarm indicator flashing
No RF power reduction.
Alarm indicator flashing
RF power reduced between 1 and 3 dB.
Alarm indicator flashing
RF power reduced between 1 and 3 dB.
Alarm indicator on
Synth Lock failure (showing a single cause of
alarm).
Alarm indicator on
RF power shut down (showing multiple causes
of alarm).