- Parker ACR Motion Controllers User Guide

Parker Hannifin
Chapter 3 Electrical Installation 59
Output Power Connector
The drive’s Motor screw terminal connector provides output power to your
motor. (For connection information, see “Output Power” on page 43.) The
con
nector differs between the two largest Aries models and the others.
Specifications for the connectors follow in this section.
On models AR-01xx through AR-13xx, the Motor connector also serves to
connect an external motor brake to the drive’s internal solid-state relay (BK).
For information on this connection, see “Brake Relay (Optional)” on page 50.
This
connector is removable.
On models AR-20xE and AR-30xE, the M
OTOR/POWER connector serves as
the connector for output power to the motor, as well as for Mains power (VAC
Input Power) and a DC Link Inductor. For information on these additional
connections, see “Input Power” on page 39 and “External DC Link Inductor
(Option
al)” on page 45. This co
nnector is not removable.
Figure 27 Output (MOTOR) Power Connector