Air Conditioning & Refrigeration Master Catalog Catalog CIC-2003-1/USA April 2003
Refrigeration & Air Conditioning Products Catalog CIC-2003-1/US Table of Contents Parker — Your Preferred Supplier ............................................................................................... .........
Refrigeration & Air Conditioning Products Catalog CIC-2003-1/US Table of Contents MORE ON PREVIOUS PAGE Thermostatic Expansion Valves: S Series, I Series, EG Series, EGC Series, RE Series, H Series, HC Series, EC Series, G Series, N Series, C Series, B5 Series; Constant Pressure (Automatic) Expansion Valves: 104A Series, 104F Series, 139 Series, 204 Series, AT Series, A7 Series, AS Series, A1 Series, A2 Series, A3 Series, AE3 Series, A4 Series, A6 Series; 625 Thermal Electric Valve Distributors, Flow R
WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Overview Parker, Your Preferred Supplier For refrigeration and air conditioning OEMs, wholesalers and contractors, Parker Hannifin offers a complete value package that makes it the supplier of choice. Solenoid valves can be mounted to a manifold in any combination. Product Breadth Parker has assembled a formidable package of refrigeration and air conditioning products.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Overview In its quest to provide premier customer service, Parker is everywhere. More than 48,000 employees work in 200+ manufacturing locations and 150+ service centers. They work in 49 countries on 6 continents and speak close to 100 languages. Another 8,200 distributors and Parker Stores provide service and support. All Parker operating units connect globally via an enterprise gateway.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Application Expertise Residential and Commerical Air Conditioning Parker knows that not all refrigeration and air conditioning applications are created equal. We have dedicated engineers and sales force with hundreds of years combined experience and knowledge in commercial, residential, industrial and supermarket systems.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Application Expertise Supermarket Refrigeration Application Expertise: Supermarket Refrigeration SC Solenoid Valve Split Condenser Hot Gas Solenoid 3-Way Hot Gas Defrost Solenoid Solenoid Valves Solenoid Valves 50% 50% EPRs HOT GAS MANIFOLD Ball Valves Check Valve Replaceable Dryer Shell & Core SUCTION HEADER Check Valve Replaceable Dryer Shell & Core Discharge Pressure Regulator Accumulator Compressors Accumulator System Liquid Subc
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Application Expertise Industrial Refrigeration Application Expertise: Industrial Refrigeration Liquid Solenoid Valve Hand Expansion Valve Globe Valve Hand Expansion Liquid Solenoid Valve Valve Globe Valve Strainer Strainer Air Unit Air Unit Angle Valve Replaceable Core Filter Angle Valve Back Pressure Regulator Purge Valve Dual Relief Valve Assembly Strainer Reseating Relief Valve Strainer Dual Relief Valve Assembly Globe Valve Con
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Application Expertise Commercial Refrigeration Application Expertise: Commercial Refrigeration (Walk-In Cooler Application) Parker — Your Preferred Supplier Evaporator Equalizer Tube Liquid Line Solenoid Valve TXV Evaporator Fan Evaporator Pressure Regulator TXV Evaporator Liquid Line Manifold Check Valve Hot Gas Defrost Valve Manifold Hot Gas Bypass Valve Liquid Desuperheater Oil Reserve Condenser Sight Glass Pressure Control Solenoi
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Application Expertise Commercial Refrigeration Application Expertise: Commercial Refrigeration (Ice Machine Application) Defrost Manifold Distributor Inverted Ice Cube Mold TXV Accumulator Water Spray Water Supply Solenoid Valve Ice Cube Bin Suction Line Full Bin Shutoff Control Drain Compressor Condenser Filter Dryer Power Source Hot Gas Bypass Solenoid Valve 10 Parker Hannifin Corporation Climate & Industrial Controls Group Clevel
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Why Parker? PHconnect PHconnect - Internet Customer Resource Parker — Your Preferred Supplier PHconnect, Parker's online resource, enables Parker customers to do the following via the internet: • enter orders • check product inventory and availability • search product catalogs • check order status • track package shipment and delivery • check account status with Parker PHconnect is available 24/7.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Why Parker? EDI — EDI (Electronic Data Interchange) Electronic Data Interchange EDI (Electronic Data Interchange) is the computer application-to-computer application communication of a standard business transaction in a standard data format. EDI users eliminate unnecessary paperwork by exchanging information directly between computers and between applications instead of by telephone, facsimile, or mail.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Why Parker? EDI (Electronic Data Interchange) Third-party communication networks or Value-Added Networks (VANS) eliminate the need for extra hardware, software, telephone connections, or manpower. Most trading partners find it convenient to use thirdparty networks.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Why Parker? • Trading partners must also have problem resolution capability, including the ability to retransmit data if it is found to be erroneous or lost due to transmission problems. Other Comments Parker divisions use the EDI Gateway to manage hundreds of trading partnerships.Translation of ANSI X.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Why Parker? Getting Started With EDI EDI Contacts Business Contact: EDI Technical Resources Manager Corporate IT Dept. Parker Hannifin Corporation 6035 Parkland Blvd. Cleveland, Ohio 44124-4141 (216) 896-3000 Technical Contact: EDI Senior Technical Analyst Corporate IT Dept. Parker Hannifin Corporation 6035 Parkland Blvd.
Parker — Your Preferred Supplier Catalog CIC-2003-1/US Notes 16 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Filter Dryers Catalog CIC-2003-1/US Table of Contents Filter Dryers Filter Dryers Table of Contents Introduction to Dryers ............................................................................................................. 19 Loose-Filled Copper Dryers .................................................................................................... 22 Service Copper Dryers ............................................................................................................
Filter Dryers Catalog CIC-2003-1/US Notes 18 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Filter Dryers Catalog CIC-2003-1/US Introduction to Dryers Filter Dryers Introduction to Dryers A dryer in a refrigeration system has two functions; one, to adsorb system contaminants such as water and acid, and two, to provide physical filtration. Parker Hannifin has developed filter dryer recommendations based on current technical data, as well as many years of actual field experience.
Filter Dryers Catalog CIC-2003-1/US Introduction to Dryers Filter Dryers Figure 1 illustrates the water capacity of different desiccants as a percent of weight in an R-12 refrigerant system. It can be determined from this that the molecular sieve desiccant retains the highest amount of moisture. This type of isotherm represents unimolecular adsorption. This is due to the strong bond between the molecular sieve and water. The activated alumina desiccant retains a fair amount of moisture, as well.
Filter Dryers Catalog CIC-2003-1/US Introduction to Dryers TABLE 4 Lubricant Alkylbenzene and Mineral Oil Alkylbenzene and Mineral Oil POE (Polyolester) Alkylbenzene/POE (Polyolester) Alkylbenzene/POE (Polyolester) POE (Polyolester) Alkylbenzene/POE (Polyolester) Alkylbenzene/POE (Polyolester) POE (Polyolester) POE (Polyolester) POE (Polyolester) POE (Polyolester) POE (Polyolester) POE (Polyolester) POE (Polyolester) Steel vs.
Filter Dryers Catalog CIC-2003-1/US Loose-Filled Copper Dryers Technical Information and Dimensions Loose-Filled Copper Dryers Parker's Loose-Filled Copper Dryers adsorb system contaminants and provide physical filtration to systems between 1/4 and 2 tons. Applications include refrigerators, freezers, ice makers, beverage dispensers, water coolers, cryogenics, and walk-in coolers. Application • Refrigeration systems between 1/4 and 2 tons. 3/4" O.D.
Filter Dryers Catalog CIC-2003-1/US Dimensions Loose-Filled Copper Dryers 1" O.D. Copper Dryer Data Part No. Design Working Pressure PSI 032083-00 500 058066-00 500 057404-00 500 Inlet Inches .250 .244 .380 .377/ .256 .253 .320 .315 Outlet Inches .098 .093 Overall Length Inches 4.00 .195 .190 4.19 .320 .315 3.81 Recommended tonnages (part numbers 032083-00 and 058066-00): 1/4 to 1/2 tons depending on application and system. Consult Parker.
Filter Dryers Catalog CIC-2003-1/US Loose-Filled Spring-Loaded Copper Dryers Technical Information and Dimensions Loose-Filled Spring-Loaded Copper Dryers Parker's Loose-Filled Spring-Loaded Copper Dryers adsorb system contaminants and provide physical filtration to air conditioning and heat-pump systems between 1/4 and 5 tons. Dryers are spring-loaded to compact the sieve load, preventing attrition by movement of the sieve material.
Filter Dryers Catalog CIC-2003-1/US Dimensions Loose-Filled Spring-Loaded Copper Dryers 1" O.D. Spring-Loaded Copper Dryer Water Capacities R-402A 75° 125° 33.2 30.6 49.4 44.8 49.4 44.8 91.5 83.0 R-402B 75° 125° 33.2 30.6 49.4 44.8 49.4 44.8 91.5 83.0 R-407A 75° 125° 24.2 22.2 49.4 44.8 49.4 44.8 91.5 83.0 Water Capacity in drops of water R-407B R-407C R-410A 75° 125° 75° 125° 75° 125° 24.2 22.2 26.2 23.6 19.8 17.4 49.4 44.8 49.4 44.8 27.3 24.3 49.4 44.8 49.4 44.8 27.3 24.3 91.5 83.0 91.5 83.0 50.
Filter Dryers Catalog CIC-2003-1/US Loose-Filled Spring-Loaded Copper Dryers Dimensions 1-5/8" O.D. Spring-Loaded Copper Dryer Data Design Part No. 032040-00 032145-00 031805-03 056244-01 056156-01 Working Pressure Inlet Outlet PSI Inches Inches .383 .383 500 .378 .378 .383 .383 500 .378 .378 .383 .383 500 .378 .378 .383 .383 500 .378 .378 .253 .253 500 .256 .256 Part No. 032040-00 032145-00 031805-03 056244-01 R-12 4.4 3.5 3.8 3.7 R-22 5.8 4.7 5.1 5 056156-01 1.3 1.8 Overall Length Inches 6.
Filter Dryers Catalog CIC-2003-1/US Service Copper Dryers Technical Information Service Copper Dryers Parker’s Service Copper Dryers adsorb system contaminants and provide physical filtration to systems. The service copper dryers provide replacement or additional dryers to systems as required. MMS-80/100 MMS-200 Application • Air conditioning, heat pump, and refrigeration systems as matched with the unique unit.
Filter Dryers Catalog CIC-2003-1/US Dimensions Service Copper Dryers Copper Service Dryer Water Capacities MRO Part No. MMS-80 MMS-100 MMS-200 712 319 619 620 621 CO73S OEM Part No. 058070-01 058198-01 032134-01 032092-00 032144-00 032142-00 032133-00 032143-00 032145-00 R-12 75° 125° 33.0 30.6 33.0 30.6 66.0 61.2 33.0 30.6 99.0 91.8 33.0 30.6 66.0 61.2 66.0 61.2 92.4 85.68 R-22 75° 125° 29.8 27.4 29.8 27.4 59.6 54.8 29.8 27.4 89.4 82.2 29.8 27.4 59.6 54.8 59.6 54.8 83.44 76.
Filter Dryers Catalog CIC-2003-1/US ® Technical Information Cu LLD Series Solid-Core Copper Dryers Cu LLD® Series Solid-Core Copper Dryers Parker's Solid-Core Copper Dryers adsorb system contaminants and provide physical filtration to systems between 1/2 and 5 tons. Applications include air conditioning, heat pumps, and ice makers. Application • Systems between 1/2 and 5 tons. Base Product Part Number Cu LLD Filter Dryers Features and Benefits • One-piece copper shells in 1-3/16" to 2" O.D.
Filter Dryers Catalog CIC-2003-1/US ® Cu LLD Series Solid-Core Copper Dryers Technical Information Cu LLD® Series Solid-Core Copper Dryers — OEM Model No. s13 s22 s23 s33 s53 s83 MRO Model No. Cu LLD 2-3S Cu LLD 3-2S Cu LLD 3-3S Cu LLD 5-3S Cu LLD 8-3S Cu LLD 16-3S 12 134a 401A 1 3/4 1 3/4 1 3/4 2 2 Installation Recommendations (Nominal Tons) Selection Recommendations (Nominal Ratings - Tons) Refrigeration Air Conditioning Commercial Low Temp.
Filter Dryers Catalog CIC-2003-1/US Technical Information CBF Bi-Flow Copper Dryers CBF Bi-Flow Copper Dryers Parker's Bi-Flow Copper Dryers adsorb system contaminants and provide physical filtration to heat-pump systems between 1-1/2 and 4-1/2 tons. Application • Heat-pump systems between 1-1/2 and 4-1/2 tons. Base Product Part Number CBF Filter Dryers Features and Benefits • One-piece copper shell with 2" O.D.
Filter Dryers Catalog CIC-2003-1/US Technical Information Gold Label Steel Liquid Line Dryers (LLD Series) Gold Label Steel Liquid Line Dryers (LLD Series) Features and Benefits • High moisture and acid capacity. Maximum filtration capacity. • Exceptional compatibility with new polyolester oils. • Compatible with all existing and new refrigerants and blends including 134a, 401A/B, 402A/B, 404A, 407A/B/C, 410A, 502, 507A. • Spring loaded, molecular sieve and activated alumina.
Filter Dryers Catalog CIC-2003-1/US Dimensions Gold Label Steel Liquid Line Dryers (LLD Series) Gold Label Steel Liquid Line Dryers Steel Liquid Line Dryer Dimensions Diameter in Inches 2 3/8 Overall Length Inches 4 3/8 5/16 3 3/4 2 3/8 4 3/8 3/8 3 11/16 2 3/8 4 3/8 053 3/8 5 1/4 2 3/8 082S 1/4 4 3/4 2 3/8 5 1/4 082 1/4 5 5/8 2 3/8 0825S 5/16 4 5/8 2 3/8 5 1/4 083S 3/8 4 9/16 2 3/8 5 1/4 083 3/8 6 2 3/8 084S 1/2 4 1/2 2 3/8 5 3/8 084 1/2 6 3/8 2 3/8 162S 1/
Filter Dryers Catalog CIC-2003-1/US Flow Capacity Gold Label Steel Liquid Line Dryers (LLD Series) Gold Label Steel Liquid Line Dryers Flow Capacity (tons of refrigerant) at pressure drop 1 psi Model No. 032 032S 032MF 052 052S 0525S 053 053S 082 082S 0825S 083 083S 084 084S 162 162S 1625S 163 163S 164 164S 165 165S 166 303 303S 304 304S 305 305S 306 307S 413 414 414S 415 415S 417S 756S 757S 759S Filter Area 10 17 27 34 61 80 131 R-12 1.27 1.41 1.27 1.41 1.48 2.47 2.97 3.54 1.41 1.56 2.62 3.
Filter Dryers Catalog CIC-2003-1/US Installation Recommendations Gold Label Steel Liquid Line Dryers (LLD Series) Gold Label Steel Liquid Line Dryers Installation Recommendations (Nominal Tons) Model No. 032 032S 12 134a Selection Recommendations (Nominal Ratings - tons) Refrigeration Air Conditioning Commercial Low Temp.
Filter Dryers Catalog CIC-2003-1/US Technical Information Sahara Series™ Sahara Series™ Liquid Line Dryers Liquid Line Dryers Available only from your local Parker wholesaler, the Sahara Series is the right dryer at the right price. Its ideal moisture removal and contaminant filtration properties make it the perfect service replacement for +40°F to 55°F suction line temperature R-22 air conditioning systems.* *(Also suitable for some refrigeration applications to +15°F. Consult Parker for details).
Filter Dryers Catalog CIC-2003-1/US Technical Information Sahara Series™ Liquid Line Dryers Dimensions Connection I.D. (A) 1/4 5/16 3/8 1/4 5/16 3/8 1/2 1/4 5/16 3/8 1/2 5/8 Cutout Length (B) 3 1/4 4 1/8 4 3/4 Overall Length (C) 4.35 4.37 4.39 5.23 5.25 5.27 5.41 5.88 5.90 5.92 6.06 6.30 Sweat Fittings Model No. (Flare Ftgs.
Filter Dryers Catalog CIC-2003-1/US Guidelines for Parker Dryers and R-410A R-410A Guidelines and Dryers Standard Products for R-410A • • • • • 100% molecular seiv e XH11 dessicant. Ensures no degradation of the R032 within the make-up of R-410A. Parker has worked with the industry in establishing a pink colored label on all products for use with R-410A. Competitive products without pink lables should not be used and may cause system damage.
Filter Dryers Catalog CIC-2003-1/US Guidelines for Parker Dryers and R-410A R-410A Guidelines and Dryers pore openings that will adsorb not only the water but the R-32, POE lubricant and it's additives, which lowers it's drying capabilities and removes essential additive's from the lubricant. It also gives the water and the lubricant a surface for the hydrolysis reaction since they can co-exist in the alumina's openings. The water is not physically separated from the lubricant.
Filter Dryers Catalog CIC-2003-1/US Guidelines for Parker Dryers and R-410A R-410A Guidelines and Dryers Figure 5 displays the reaction of molecular sieve and activated alumina with a POE lubricant and HFC refrigerant. After exposure of the desiccants to the POE and HFC refrigerant in a sealed glass tube for 14 days and 180° F, the activated alumina showed organic acid levels almost 40 times higher than that of molecular sieve. This is an indication of the breakdown of the lubricant.
Filter Dryers Catalog CIC-2003-1/US Technical Information Steel Bi-Flow Filter Dryers (BF Series) Steel Bi-Flow Filter Dryers — BF Series The "BF" Series bi-flow dryer is designed specifically for heat pump or reverse cyle application. External check valves are not required since they are incorporated within the filter dryer shell. The core design filters out contaminant particles down to 25 microns. Features and Benefits • • Bi-flow Dryers — • • • Dimensions design for R-410A applications.
Filter Dryers Catalog CIC-2003-1/US Technical Information Bi-Flow Dryers, Gold Label Steel Suction Line Filter Dryers Bi-Flow Dryer Flow Capacity — Tons of Refrigerant at Pressure Drop 1 PSI Model No. BF082S BF083S BF084S BF083 BF084 BF162S BF163S BF164S BF165S BF163 BF164 BF163S-XF Filter Area cu inches 10.4 14.4 R-12 1.6 2.1 2.7 2.1 2.7 1.6 2.2 2.7 3.7 2.1 2.7 2.7 R-22 2.1 2.8 3.5 2.8 3.5 2.1 2.9 3.5 4.9 2.8 3.5 3.
Filter Dryers Catalog CIC-2003-1/US Technical Information Gold Label Steel Suction Line Filter Dryers Steel Suction Line Dryer Dimensions A Overall Length Inches 5.13 4.31 5.38 4.44 4.66 4.72 5.82 4.91 4.97 4.97 5.72 6.97 7.72 12 12 B System Cutout Length - Inches 3.13 3.13 3.16 3.16 3.45 3.45 3.47 3.47 5.47 5.36 9.17 9.17 Shell Diameter Inches 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 Filter Dryers Model No.
Filter Dryers Catalog CIC-2003-1/US Technical Information Gold Label Steel Suction Line Filter Dryers Steel Suction Line Filter Dryer Ratings and Capacities Refrigerant Evaporator Temp Pressure Drop PSI 22 40° F 20° F 0° F 134a -20° F -40° F 40° F 20° F R-404A 0° F -20° F 40° F 20° F 0° F R-407A & R-407C -20° F -40° F 40° F 20° F 0° F -20° F -40° F 3 2 1.5 1 0.5 2.0 1.5 1.0 0.5 3.0 2.0 1.5 1.0 0.5 3.0 2.0 1.5 1.0 0.5 SLD 8-3V-HH 1.1 0.8 0.6 0.4 0.2 0.7 0.6 0.5 0.
Filter Dryers Catalog CIC-2003-1/US Technical Information Sahara Series™ Filter Dryers Sahara Series™ Suction Line Dryers Suction Line Parker Hannifin has expanded its line of suction line dryers to give contractors unmatched versatility in servicing air conditioning and refrigeration systems. The new Sahara Series suction line dryers come in standard lay-in length sizes and join Parker’s existing line of compact-size, Gold Label SLD suction line dryers.
Filter Dryers Catalog CIC-2003-1/US Technical Information Replacement Dryer Shells and Filter Cores Replacement Dryer Shells and Filter Cores Parker replacement filter cores and dryer shells are designed to provide flexibility over a widerange of applications. All models are designed for use in both the liquid and suction line of refrigeration or air conditioning systems. In single or multiple-core applications, cores may be loaded individually for ease of installation in tight spots.
Filter Dryers Catalog CIC-2003-1/US Technical Information Replacement Dryer Shells and Filter Cores Filter Elements and Cores Z-48 Super High Capacity Core Most highly recommended for use with POEs. Formulated for use with the new refrigerants, blends and synthetic polyolester oils. For hi-moisture, acid, sludge and particulate removal. The Z-48 has 3 times the moisture capacity of standard cores.
Filter Dryers Catalog CIC-2003-1/US Technical Information Replacement Dryer Shells and Filter Cores Replacement Filter Core Dryer Water Drop Capacity at ARI Conditions Core Model PCX-48 PCK-48HH PCK-48 Z-48 PCK-100 R-12 (15 ppm) 75° F/125° F 770/607 524/374 607/447 1833/1660 1572/1235 R-22 (60 ppm) 75° F/125° F 697/524 474/322 549/386 1659/1433 1422/1066 R-134a (150 ppm) 75° F/125° F 762/591 518/363 600/435 1814/1614 1556/1201 R-401A/B (50 ppm) 75° F/125° F 746/551 507/339 587/406 1775/1505 1522/11
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Table of Contents Pre-Filters, Oil Devices and Strainers Pre-Filters, Oil Devices and Strainers Table of Contents PF Series ......................................................................................................................... page 51 SPD Series ...................................................................................................................... page 51 LP Gas Filter .......................................
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Notes 50 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Technical Information PF Series, SPD Series, LP Gas Filter Filters and Pre-Filters Parker provides a large selection of components for recovery, recycle and reclaim machines, protecting them from the many types of contaminants that are encountered during the servicing of systems. PF Series The PF 052 & PF 052MF are designed to provide a filtration level of 15 microns.
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Technical Information and Dimensions PRD-3 Series, Oil Vapor Dryer Separator PRD-3 Series Specifically designed for OEM recovery units that require 3/8" flare connections and a larger cross sectional filter area. The PRD-3 filter dryer meets or exceeds OEM specifications providing both value and efficiency. Features and Benefits • High acid and high moisture capacity. • Enlarged filtration area. • 3/8" SAE male flare fittings on both ends.
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US POS-321 Oil Separator, Oil Reservoirs, PS-033 Oil Strainer Technical Information POS-321 Oil Separator The Parker oil separator removes oil from system refrigerant by means of a highly efficient coalescing filter. The filter is 98.5% efficient, filtering oil and particles down to 1/10 of a micron while leaving a trace amount of oil necessary for adequate system lubrication. The separator is ideal for recovery and reclaim operations.
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Copper Strainers Technical Information and Dimensions Copper Strainers Parker's Copper Strainers are used in refrigeration and air conditioning systems to filter sediment, to protect refrigerant metering devices such as capillary tubing, and to protect other components such as valves and compressors. Screen sizes are selected to ensure that all targeted amounts and sizes of particles are trapped without causing substantial pressure drop.
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Dimensions Copper Strainers 5/8" O.D. Copper Strainers — Standard Products Parker Part No. 054139-00 Design Working Filtration Pressure Capacity PSIG Microns 500 140 Screen Area Sq. In. 0.75 Inlet Inches 1/4 Outlet Inches .147-.152 Overall Length Inches 2.25 3/4" O.D. Copper Strainers (C) Outlet Inches I.D. 1/4 5/16 3/8 OD 3/8 1/2 OD 1/2 3/8 Overall Length In. (A) 2.75 2.75 2.75 2.75 2.75 3 5.
Pre-Filters, Oil Devices and Strainers Catalog CIC-2003-1/US Copper Strainers Dimensions 1-3/16" O.D. Copper Strainers STANDARD PRODUCT Design Working Filtration Pressure Capacity Part No. PSIG Microns 058307-00 500 140 MODIFIED STANDARD 441901 500 104 Screen Area Sq. In. 8.37 (B) (C) Inlet Outlet Inch I.D. Inches I.D. 1/2 1/2 Overall Length In. (A) 5.13 2.32 see chart below 5.8-6.5 Outlet Options Outlet 0.099 0.106 0.112 0.125 No.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Table of Contents Accumulators, Receivers, Tanks and Mufflers Accumulators, Receivers, Tanks and Mufflers Table of Contents Introduction to Accumulators ....................................................................................... page 59 Steel Suction Line Accumulators ................................................................................. page 61 Copper Accumulators .................................................
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Notes 58 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Introduction to Accumulators Accumulators Introduction to Accumulators The prime function of a suction line accumulator in a heat pump or refrigeration system is to catch and hold any unused portion of the system charge. It must also prevent liquid slugging of the compressor and excessive refrigerant dilution of the compressor oil.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Introduction to Accumulators New Refrigerants The introduction of new refrigerants and oils has created new problems in the design of all system components and suction accumulators are no exception. As mentioned earlier, the accumulator is the coldest component in the system. The new refrigerants and the oils they are used with may not be fully miscible in the temperature range the accumulator normally operates.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information Steel Suction Line Accumulators Steel Suction Line Accumulators “U” Tube Style Accumulators The Parker “U” tube accumulator design is a result of extensive laboratory testing plus detailed investigation of the various accumulators currently available.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Dimensions and Flow Data Steel Suction Line Accumulators Steel Suction Line Accumulator Dimensions and Flow Data Recommended capacity in tons of refrigeration Model No. 134a 401A 402A 407C 410A 502 & 507A Solder Dimensions Evap. 22 & 404A (Inches) Capacity1 Temp. Tons @ Min. Tons @ Min. Tons @ Min. Tons @ Min. Tons @ Min. Tons @ Min. Tons @ Min. Fitting Size Length O.D. °F (oz.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information and Dimensions Stand Pipe Style Steel Accumulators Stand Pipe Style Steel Accumulators Features and Benefits • Available in 2-1/2", 3" and 4" diameters. • Copper and copper plated steel fittings • Standard fitting sizes: 3/4" and 7/8". Other sizes available upon request. • Dual, screened orifice design. Various orifice sizes available. • U.L. listed file no. SA5172, CSA certified.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information Vertical, Horizontal and Stand-Pipe Copper Accumulators Vertical, Horizontal, and Stand-Pipe Copper Accumulators Parker's Vertical, Horizontal, and Stand-Pipe Copper Accumulators hold unused system charge to prevent liquid slugging of the compressor and excessive refrigerant dilution of the compressor oil.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Dimensions Vertical, Horizontal and Stand-Pipe Copper Accumulators 1-1/8" Copper Accumulator Part No. 032185-00 Design Working Standard Nominal Sizes (Inches) Pressure PSIG Inlet (A) Outlet (B) 500 3/8 1/4 Overall Length Internal Volume Inches (C) (Cu. In.) 8.25 1.97 1-3/16" Copper Accumulator Part No.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Dimensions Vertical, Horizontal and Stand-Pipe Copper Accumulators 1-1/8" Copper Stand Pipe Accumulator Part No. 032014-00 071440-00 Design Working Standard Nominal Sizes (Inches) Pressure PSIG Inlet (A) Outlet (B) 325 3/8 0.477 325 1/2 0.589 A Overall Length Internal Volume Inches (C) (Cu. In.) 6.44 2.48 7.25 2.14 C B A 1-7/8" Copper Stand Pipe Accumulator Part No.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information and Dimensions Steel Receivers Steel Receivers Features and Benefits • Designed for refrigerant storage during normal operation and system pump down. • Allows the system to adjust to varying system conditions and loads. • Available in 4", 5" and 6" diameters (2 1/2" and 3" diameter vertical receivers and horizontal receiver models available. Consult Parker). • Available up to 36" in length.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information and Dimensions Compensator Tanks Compensator Tanks A compensator tank is a mode dependent receiver that can be used in a heat pump system. As the heating mode does not require as much refrigerant as the cooling mode, the compensator tank stores the excess refrigerant. Features and Benefits • Available with 5/8", 3/4" and 7/8" suction line connections — steel or copper sweat.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information and Dimensions Copper Mufflers Copper Mufflers Parker's Copper Mufflers are used in refrigeration and air conditioning systems to provide noise attentuation associated with pressure pulses from the compressor. The muffler is usually mounted vertically and flowing downward in the compressor discharge line for efficient oil movement. Internal baffles can be provided for additional dissipation of pressure pulsing.
Accumulators, Receivers, Tanks and Mufflers Catalog CIC-2003-1/US Technical Information and Dimensions Steel Mufflers Steel Mufflers Parker steel mufflers are designed to assist with today's and future compressor related difficulties such as noise reduction due to compressor pulsation and/or turbulent gas flow or vibration through the discharge line. Features and Benefits • UL/CSA listed for 500 psig design pressure. (Selected models listed at 600 psig — consult Parker for details.
Sight Glass Moisture Indicators Catalog CIC-2003-1/US Table of Contents Sight Glass Moisture Indicators Sight Glass Moisture Indicators Table of Contents PSG Sight Glass and Moisture Indicator .....................................................................
Sight Glass Moisture Indicators Catalog CIC-2003-1/US Notes 72 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Sight Glass Moisture Indicators Catalog CIC-2003-1/US PSG Sight Glass and Moisture Indicator Technical Information and Dimensions PSG Sight Glasses and Moisture Indicators Parker’s PSG Sight Glass and Moisture Indicator provides a quick visual diagnosis of refrigerant and moisture levels within a system. The sight glass indicates if the system has the proper refrigerant level, a restricted dryer, or excessive pressure-drop. The moisture indicator recognizes moisture within the system.
Sight Glass Moisture Indicators Catalog CIC-2003-1/US Notes 74 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Couplings Catalog CIC-2003-1/US Table of Contents Couplings Couplings Table of Contents Introduction to Parker Couplings ................................................................................. page 77 System Couplings 5400 Series Self-Sealing Steel Couplings ............................................................. page 78 5500 Series Self-Sealing Brass Couplings ............................................................ page 84 5700 Series One-Shot™ Brass Couplings ...................
Couplings Catalog CIC-2003-1/US Notes 76 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Couplings Catalog CIC-2003-1/US Introduction Introduction to Parker Couplings Introduction to Parker Couplings Parker Hannifin has the broadest Coupling Product offering in the market. Whether it's Quick Connect, Self-Sealing upon disconnection, Brass or Steel Material, Parker has what you need. With applications ranging from room air-conditioners to cryogenic pumps, Parker has the product you are looking for.
Couplings Catalog CIC-2003-1/US Technical Information 5400 Series Self-Sealing Steel Couplings 5400 Series Self-Sealing Steel Couplings Parker’s 5400 Self-Sealing Steel Couplings are used in fluid-transfer applications for easy maintenance on refrigeration and air conditioning systems. Applications can also include marine refrigeration and air conditioning systems, along with cryogenic units.
Couplings Catalog CIC-2003-1/US Performance Data 5400 Series Self-Sealing Steel Couplings Liquid Line Pressure Drop vs. Mass Flow Refrigerant R22 Refrigerant Mass Flow (Kg/Hr) 122 163 204 245 286 327 368 Press Drop Versus Flow 408 31.0 4.0 27.6 3.5 24.1 3.0 20.7 2.5 17.2 5400-6-4 2.0 2.0 1.5 10.3 1.0 50 45 40 35 30 25 5400-8-8 15 -8 -4 -12 -18 10 9 8 7 6 5 4 3.9 3 3.4 2 5400-6-8 0.5 20 Pressure Drop (psi) Pressure Drop (PSI) 4.
Couplings Catalog CIC-2003-1/US 5400 Series Self-Sealing Steel Couplings Dimension Data 5400-S2 5400-S5 A Male Half No Adapter A Female Half No Adapter T2 Thread T2 Thread H Hex Part Number Neoprene 5400-S2-4 5400-S2-8 5400-S2-12 5400-S2-16 Coupling T1 Size Thread -4 5/8 - 18UNF -8 1 - 20UNEF -12 1-7/16 - 16UN -16 1-3/4 - 16UN T1 Thread 5401-S14 Coupling T1 Size Thread -4 1/2 - 20 -8 7/8 - 20 -12 1-1/4 - 18 -16 1-19/32 - 20NS H1 Hex 0.75 1.19 1.63 2.00 A 1.13 1.63 2.15 2.37 H2 Hex 0.63 1.
Couplings Catalog CIC-2003-1/US Dimension Data 5400 Series Self-Sealing Steel Couplings 5410-S17-No-No T2 Thread Male Half SAE 37° (JIC) Part Number Neoprene 5410-S17-4-4 5410-S17-6-4 5410-S17-6-8 5410-S17-8-8 5410-S17-10-12 5410-S17-12-12 5410-S17-16-16 Coupling T1 Size Thread 4-4 5/8 - 18UNF 6-4 5/8 - 18UNF 6-8 1 - 20UNEF 8-8 1 - 20UNEF 10-12 1-7/16 - 16UN 12-12 1-7/16 - 16UN 16-16 1-3/4 - 16UN A 1.88 1.89 2.18 2.28 2.75 2.86 2.99 H1 Hex 0.75 0.75 1.13 1.13 1.63 1.63 1.
Couplings Catalog CIC-2003-1/US 5400 Series Self-Sealing Steel Couplings Components Typical Male Coupling Half (S2) Item No. Dash Size > Tube O.D.
Couplings Catalog CIC-2003-1/US Assembly Instructions and Accessories 5400 Series Self-Sealing Steel Couplings Assembly Instructions Step 5 Coupling connection. Step 1 After tubing or hose has been connected to adapters (1) and (12), install adapter O-rings (2) and (11)* on adapters. Be sure O-rings are not twisted. A. Generously lubricate the gasket seal (5) on the 5400-S2 male coupling half with the system lubricant.
Couplings Catalog CIC-2003-1/US Technical Information 5500 Series Self-Sealing Brass Coupling 5500 Series Self-Sealing Brass Coupling Parker’s 5500 Self-Sealing Brass Couplings are used in fluid-transfer applications for easy maintenance on refrigeration and air conditioning systems. Applications can also include marine refrigeration and air conditioning systems, along with split refrigeration and split beverage systems.
Couplings Catalog CIC-2003-1/US Technical Information 5500 Series Self-Sealing Brass Coupling How it Operates Disconnected When disconnected, spring-loaded valve assemblies in the male and female coupling halves are sealed to prevent refrigerant loss and the inclusion of air or foreign materials. A spring in the male coupling half presses the bonded poppet against sealing surface “A” of the coupling body.
Couplings Catalog CIC-2003-1/US 5500 Series Self-Sealing Brass Coupling Technical Information Specifications PRODUCT Operating Temperature Range Operating Pressure Range, Connected Male & Female Coupling -06, -08, -12 & -16 Body Sizes Operating Pressure Range, Disconnected Male Coupling Half -06, -08, -12 & -16 Body Sizes Female Coupling Half -06 & -08 Body Sizes -12 Body Size -16 Body Size Minimum Burst Pressure, Connected Male & Female Coupling -06, -08, -12 & -16 Body Sizes Minimum Burst Pressure, Dis
Couplings Catalog CIC-2003-1/US Technical Information 5500 Series Self-Sealing Brass Coupling Flow Data Liquid Line Pressure Drop vs. Mass Flow Refrigerant R22 and R410a 41 82 Refrigerant Mass Flow (Kg/Hr) 163 204 245 122 286 327 368 408 31.0 4.5 4.0 27.6 ) 0a 41 0 50 5 3.0 8 -0 04 00 55 24.1 ) 22 (R 20.7 2.5 17.2 2.0 13.8 1.5 10.3 1.0 3.9 410a) 6-06 (R 5500-0 0.
Couplings Catalog CIC-2003-1/US 5500 Series Self-Sealing Brass Coupling Dimensions Coupling Assembly Copper Connection Inch (Dash Size*) 1/4 ODS (-04) 3/8 ODS (-06) 1/4 ODS (-04) 3/8 ODS (-06) 1/2 ODS (-08) 5/8 ODS (-10) 5/8 ODS (-10) 3/4 ODS (-12) 7/8 ODS (-14) 7/8 ODS (-14) 1 ODS (-16) 1-1/8 ODS (-18) mm 6.4 ODS 9.5 ODS 6.4 ODS 9.5 ODS 12.7 ODS 15.9 ODS 15.9 ODS 19.1 ODS 22.2 ODS 22.2 ODS 25.4 ODS 28.
Couplings Catalog CIC-2003-1/US Dimensions 5500 Series Self-Sealing Brass Coupling Female Coupling Half Copper Connection Inch (Dash Size*) 1/4 ODS (-04) 3/8 ODS (-06) 1/4 ODS (-04) 1/4 ODS (-04) 3/8 ODS (-06) 3/8 ODS (-06) 12 ODS (-08) 6.4 ODS 9.5 ODS 6.4 ODS 6.4 ODS 9.5 ODS 9.5 ODS 12.7 ODS 12.7 ODS 15.9 ODS 15.9 ODS 15.9 ODS 19.1 ODS 22.2 ODS 22.2 ODS 25.4 ODS 28.
Couplings Catalog CIC-2003-1/US 5500 Series Self-Sealing Brass Coupling Dimensions Male Coupling Half Copper Connection Coupling Body Part Number** Dimensions Coupling Length Inch (Dash Size*) 1/4 ODS (-04) 3/8 ODS (-06) 1/4 ODS (-04) 1/4 ODS (-04) 3/8 ODS (-06) 3/8 ODS (-06) 1/2 ODS (-08) 1/2 ODS (-08) 5/8 ODS (-10) 5/8 ODS (-10) 5/8 ODS (-10) 3/4 ODS (-12) 7/8 ODS (-14) 7/8 ODS (-14) 1 ODS (-16) 1-1/8 ODS (-18) mm 6.4 ODS 9.5 ODS 6.4 ODS 6.4 ODS 9.5 ODS 9.5 ODS 12.7 ODS 12.7 ODS 15.9 ODS 15.
Couplings Catalog CIC-2003-1/US Accessories 5500 Series Self-Sealing Brass Coupling Protective Plugs (Bulk package, 25/package) Protective Caps (Bulk package, 25/package) Coupling Body Size (Dash Size*) mm Dimensions Part Number Length A Weight Coupling Body Size (Dash Size*) Diameter Ounces B (Grams) Plastic 3/8 (-06) 1/2 (-08) (-08) 3/4 (-12) 1 (-16) mm Part Number Length A 9.5 5409-06-BULK 12.7 5409-08-BULK Weight Diameter Ounces B (Grams) Plastic 9.5 5410-06-BULK 12.
Couplings Catalog CIC-2003-1/US 5500 Series Self-Sealing Brass Coupling Ordering Information How to Order 5502 04 B 06 Coupling Type Copper Connection Size Cap Requirements Coupling Body Size Product Type 5502 = Male Coupling Half 5505 = Female Coupling Half -04 -06 -08 -10 -12 -14 -16 -18 Copper Connection (Denoted xx/16) = 1/4" (6.4 mm) = 3/8" (9.5 mm) = 1/2" (12.7 mm) = 5/8" (15.9 mm) = 3/4" (19.1 mm) = 7/8" (22.2 mm) = 1" (25.4 mm) = 1-1/8" (28.
Couplings Catalog CIC-2003-1/US Technical Information 5700 Series One-Shot™ 5700 Series One-Shot™ Brass Couplings Brass Couplings Parker’s 5700 One-Shot Brass Couplings are used in fluidtransfer applications for easy installation on refrigeration and air conditioning systems. Applications typically include split air conditioning systems, split heat pumps, and manufactured homes.
Couplings Catalog CIC-2003-1/US 5700 Series One-Shot™ Brass Couplings Technical Information Pressure Drop Comparison The graphs below show significant reduction in pressure drop and associated efficiency gains utilizing Parker 5700 Series Couplings vs. standard base valves. Pressure Drop vs. Mass Flow Pressure Drop vs. Mass Flow -10 Suction Line, Refrigerant -22 -8 Suction Line, Refrigerant -22 5.0 5.
Couplings Catalog CIC-2003-1/US 5700 Series One-Shot™ Brass Couplings Technical Information Design and Operation A complete 5780 Series Coupling consists of the combination of male and female coupling halves. Either coupling half is available with or without a charging port, depending on the particular application. Coupling Halves Before Connection Diaphragms in the coupling halves provide a seal that prevents refrigerant loss before connection.
Couplings Catalog CIC-2003-1/US 5700 Series One-Shot™ Brass Couplings Dimensions 5780-Size Female Half without Charge Port 5781-Size Female Half with Charge Port 5782-Size Male Half without Charge Port 5783-Size Male Half with Charge Port 96 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Couplings Catalog CIC-2003-1/US 5700 Series One-Shot™ Brass Couplings Installation Instructions Factory Brazing Instructions Step 1 Sparingly apply paste flux to the copper tube. Note: Liquid flux or excessive flux can run inside the coupling and cause corrosion. Step 4 After the alloy solidifies, quench the tubing and coupling to reduce the temperature below 400° F. Make sure the water does not enter the open charge port in the 5781 or 5783 half.
Couplings Catalog CIC-2003-1/US 5700 Series One-Shot™ Brass Couplings Installation and Reconnection Instructions Installation Instructions Step 1 Braze coupling to clean copper tubing. Step 6 Evacuate and charge the line set per the manufacturer's instructions. Retighten the charge port cap. Step 2 Install plastic dust plug. Step 3 Apply refrigeration oil to the diaphragm and threads of the couplings on the indoor unit. Step 4 Connect the line set couplings finger tight. Do not use a wrench.
Couplings Catalog CIC-2003-1/US 5700 Series One-Shot™ Brass Couplings Accessories and Ordering Information Order Options Charging Port Cap Mounting Flange Male Coupling Half Female Coupling Half Basic Coupling Size -6 -6 -6 -8 -8 -8 -10 -10 -10 -11 -11 -11 -11 -12 -12 -12 O.D.
Couplings Catalog CIC-2003-1/US RC04 Series Dual-Line ConnectAire™ Couplings Technical Information RC04 Series Dual-Line ConnectAire™ Couplings Parker’s RC04 Dual-Line ConnectAire™ Couplings are used in fluid-transfer applications for easy maintenance on refrigeration and air conditioning systems. Applications can also include portable air conditioners, split refrigeration systems, and mini-split air conditioning & heat pump systems up to 2-tons.
Couplings Catalog CIC-2003-1/US RC04 Series Dual-Line ConnectAire™ Couplings Dimensions & Installation Instructions Dimension Data Installation Instructions To Disconnect: Step 1 Ensure that the handle on the female coupling is in a reclined position away from the mating male coupling Step 1 Shut down the A/C unit and unplug the electrical power cord from the wall outlet. Step 2 Retract the “Release Sleeve” on Female Coupling and insert the mating male coupling, located on the outside unit.
Couplings Catalog CIC-2003-1/US RC04 Series Dual-Line ConnectAire™ Couplings Options Female Mounting Option Protective Transition Boot Male Half — Female Half — Protective Cap for Male Half 102 Protective Plug for Female Half Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Couplings Catalog CIC-2003-1/US RC01C Series Automotive R134A Process Coupling Technical Information RC01C Series Automotive R134A Process Coupling Parker’s RC01C Automotive Process Coupling provides easy evacuating and charging of HFC-134a mobile air conditioning systems.
Couplings Catalog CIC-2003-1/US RC01C Series Automotive R134A Process Coupling Dimensions RC01C-002 Service Coupling Assembly Low Side, R134a 1.75 Open Position M14X1.5– 6H Thread 1.08 Ref 1.23 Ref. Ø 1.31 Ref Ø 1.25 Ref RC01C-003 Service Coupling Assembly High Side, R134a 1.71 Ref Open Position M14X1.5– 6H Thread 1.05 Ref 1.23 Ref. Ø 1.25 Ref Ø 1.
Couplings Catalog CIC-2003-1/US Technical Information RC05 Series Multi-Purpose Process Coupling RC05 Series Multi-Purpose Process Coupling Parker’s RC05 Multi-Purpose Process Coupling provides rapid in-plant processing of air conditioning and heat pump systems. A service adapter also provides evacuation and charging of units in the field. Application Features and Benefits • Residential split-system air conditioners and heat pumps. • Packaged air conditioners and heat pumps. • Ice making systems.
Couplings Catalog CIC-2003-1/US Technical Information & Dimensions FD57 Series Stub Kit Couplings FD57 Series Stub Kit Couplings Application • Factory precharged heat pump and split-type air conditioning systems. Base Product Part Number FD57 - XXXX - Copper size - coupling size Features and Benefits • Easy installation of replacement units. • Direct copper braze capability. Agency Approvals UL Recognized; File No. SDTW 2.
Couplings Catalog CIC-2003-1/US FD57 Series Stub Kit Couplings Dimensions FD57-1128 90° Commercial (Residential) Freon with Copper Tube Stub Part Number FD57-1128-04-06 FD57-1128-05-06 FD57-1128-06-06 FD57-1128-08-10 FD57-1128-08-11 FD57-1128-10-10 FD57-1128-10-11 FD57-1128-12-10 FD57-1128-12-11 FD57-1128-12-12 FD57-1128-14-11 FD57-1128-14-12 Thread T 5/8-18 5/8-18 5/8-18 1-1/16-12 1-1/8-12 1-1/16-12 1-1/8-12 1-1/16-12 1-1/8-12 1-1/16-12 1-1/8-12 1-1/16-12 A Ref. 1.92 2.30 2.30 2.81 2.85 2.86 2.90 2.
Couplings Catalog CIC-2003-1/US FD57 Series Stub Kit Couplings Dimensions FD57-1147 " Commercial (Residential) Freon with Charge Port and Copper Tube Stub Part Number FD57-1147-06-06 FD57-1147-06-11 FD57-1147-08-10 FD57-1147-08-12 FD57-1147-10-12 Thread T 5/8-18 1-1/8-12 1-1/16-12 1-7/16-12 1-7/16-12 A Ref. 4.34 4.50 5.53 5.89 6.31 B Ref. 0.81 1.31 1.31 1.69 1.69 C Ref. 0.31 0.31 0.38 0.38 0.38 D Ref. 0.38 0.38 0.50 0.50 0.62 E Ref. 0.62 1.00 1.00 1.38 1.
Couplings Catalog CIC-2003-1/US FD57 Series Stub Kit Couplings Dimensions FD57-1148 " 90° Commercial (Residential) Freon with Charge Port and Copper Tube Stub Part Number FD57-1148-06-06 FD57-1148-06-11 FD57-1148-08-10 FD57-1148-08-12 FD57-1148-10-12 Thread T 3/4-18 1-1/8-12 1-1/16-12 1-1/16-16 1-1/16-16 A Ref. 2.55 2.85 3.06 3.64 3.51 B Ref. 0.81 1.31 1.31 1.69 1.69 C Ref. 2.16 2.06 2.94 2.72 3.32 D Ref. 0.31 0.31 0.38 0.38 0.50 E Ref. 0.38 0.38 0.50 0.50 0.62 F Ref. 0.62 1.00 1.00 1.38 1.
Couplings Catalog CIC-2003-1/US Dimensions FD57 Series Stub Kit Couplings FD57-1146 5700 Series Coupling Half with Copper Tube Stub Part Number FD57-1146-06-06 FD57-1146-06-11 FD57-1146-08-10 FD57-1146-08-12 FD57-1146-10-12 Thread T 3/4-18 1-1/8-12 1-1/16-12 1-1/16-16 1-1/16-16 A Ref. 3.14 3.30 3.22 3.53 3.65 B Ref. 0.87 1.30 1.23 1.66 1.66 C Ref. 0.38 0.38 0.50 0.50 0.62 D Ref. 0.75 1.12 1.06 1.44 1.
Couplings Catalog CIC-2003-1/US Dimensions FD57 Series Stub Kit Couplings FD57-1133 " 5700 Series Coupling Half with Charge Port and Copper Tube Stub Part Number FD57-1133-05-06 FD57-1133-06-06 FD57-1133-10-11 FD57-1133-12-11 FD57-1133-14-11 Thread T 5/8-18 5/8-18 1-1/8-12 1-1/8-12 1-1/8-12 A Ref. 4.25 4.25 5.96 5.96 5.94 B Ref. 0.62 0.62 1.12 1.12 1.12 C Ref. 0.31 0.31 0.5 0.62 0.75 D Ref. 0.31 0.38 0.62 0.75 0.
Couplings Catalog CIC-2003-1/US Notes 112 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Service and Check Valves Catalog CIC-2003-1/US Table of Contents Service and Check Valves Service and Check Valves Table of Contents Service Valves Frontseating Valves ............................................................................................... page 115 RB01 Series Ball Valves ........................................................................................ page 117 Backseating Valves ..............................................................................................
Service and Check Valves Catalog CIC-2003-1/US Notes 114 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Service and Check Valves Catalog CIC-2003-1/US Technical Information Frontseating Valves Frontseating Valves Parker’s Frontseating Valves are used as service valves in split air-conditioning and heat-pump systems. The valves isolate sections of a system for servicing and provide a means for charging refrigerant into a unit. Application • Residential split-system air conditioners and heat pumps Agency Approvals U.L. recognized; File No: SA5188 CSA approval; File No.
Service and Check Valves Catalog CIC-2003-1/US Installation Instructions Frontseating Valves Factory Installation Step 1 Attach the valve using the mounting procedure that best suits the application. Clean the tubing to be brazed to the Parker frontseating valve. Step 2 Flux the copper tubing and insert into the stub. Flux is not required if a low to zero-silver braze alloy is used. Braze the joint.
Service and Check Valves Catalog CIC-2003-1/US Technical Information RB01 Series Ball Valves RB01 Series Ball Valves Parker’s RB01 Ball Valves are used as service valves in split air conditioning and heat-pump systems or in commercial refrigeration applications. The valves isolate sections of a system for servicing and provide a means for charging refrigerant into a unit.
Service and Check Valves Catalog CIC-2003-1/US RB01 Series Ball Valves Technical Information Specifications RB01 Series Ball Valves Refrigerant R22 40°F Saturated Suction with 10°F Superheat 1.00 Vacuum to 750 psi 0.90 0.
Service and Check Valves Catalog CIC-2003-1/US RB01 Series Ball Valves Dimensions Pad Mount RB01-031, RB01-032, RB01-033 Field Connection 1 Factory Connection 5 3 Part Numbers No. 1 Mtg Position No.
Service and Check Valves Catalog CIC-2003-1/US RB01 Series Ball Valves Dimensions Post Mount RB01-034, RB01-035, RB01-036 Factory Connection Field Connection 1 5 3 Connection Part Numbers No. 1 Mtg Position No.
Service and Check Valves Catalog CIC-2003-1/US RB01 Series Ball Valves Dimensions No Mount RB01-019 Factory Connection Field Connection Dimensions Connection Factory 5/8" ODS 3/4" ODS 3/4" ODS 7/8" ODS 7/8" ODS 1-1/8" ODS 1-1/8" ODS 1-1/8" ODS 1-3/8" ODS Field 5/8" ODS 3/4" ODS 3/4" ODS 7/8" ODS 1-1/8" ODS 1-1/8" ODS 1-1/8" ODS 1-3/8" ODS 1-3/8" ODS Part Numbers RB01-019-101010 RB01-019-121012 RB01-019-121412 RB01-019-141414 RB01-019-141418 RB01-019-181418 RB01-019-181818 RB01-019-181822 RB01-019-
Service and Check Valves Catalog CIC-2003-1/US RB01 Series Ball Valves Ordering Information Available Options Mounting Type: Gauge Port Location: Available Options Pad Mount, Post-Stud Mount or No Mount Left-Hand Gauge Port with Mounting Positions 2-5 Gauge Port Locations Viewed from the Field Connection Right-Hand Gauge Port with Mounting Positions 1-4 Ship Ball Open or Ball Closed* Position: Gauge Port Brass* or Plastic Cap: * Provided with standard product offering How to Order RB01 019 12 10
Service and Check Valves Catalog CIC-2003-1/US Technical Information Backseating Valves Backseating Valves Parker’s Backseating Valves are used as service valves in air-conditioning and heat-pump systems. The valves isolate sections of a system for servicing and provide a means for charging refrigerant into a unit.
Service and Check Valves Catalog CIC-2003-1/US Technical Information RB8 Series Multi-Function Cooling-Only Flare Valves RB8 Series Multi-Function Cooling-Only Flare Valves Parker’s RB8 Multi-Function Flare Valves are used as service valves in mini-split air conditioners. The valves isolate sections of a system for servicing and provide a means for charging refrigerant into a unit. The valve also holds a restrictor and screen to meter refrigerant and filter debris, increasing system efficiency.
Service and Check Valves Catalog CIC-2003-1/US RB9 Series Multi-Function Heat-Pump Flare Valves Technical Information RB9 Series Multi-Function Heat-Pump Flare Valves Parker’s RB9 Multi-Function Flare Valves are used as service valves in mini-split heat pumps. The valves isolate sections of a system for servicing and provide a means for charging refrigerant into a unit. The valve also holds a restrictor and screen to meter refrigerant and filter debris, increasing system efficiency.
Service and Check Valves Catalog CIC-2003-1/US Technical Information and Dimensions Copper Check Valves Check Valves Check valves are designed to allow flow in one direction only. They are used to prevent backwards flow through dryers and other devices that are designed for directional flow. Copper Ball Check Valves Parker's Copper Ball Check Valves are used in refrigeration and air conditioning systems to maintain flow in only one direction.
Service and Check Valves Catalog CIC-2003-1/US Technical Information and Dimensions Soft-Seat Copper Check Valves Soft-Seat Copper Check Valves Parker's Soft-Seat Copper Check Valves are used in refrigeration and air conditioning systems to maintain flow in only one direction. Internal components seat or “check,” preventing flow back through the valve.
Service and Check Valves Catalog CIC-2003-1/US Technical Information and Dimensions Brass Check Valves 1/4" Brass Check Valve Features and Benefits • Poppet style valve incorporates o-ring sealing surface. • Brass body and piston resist corrosion. • Stainless steel spring resists corrosion. • Braze connections. Dimensions 3/8" Brass Check Valve Features and Benefits • Poppet style valve incorporates o-ring sealing surface. • Brass body and piston resist corrosion.
Service and Check Valves Catalog CIC-2003-1/US Technical Information and Dimensions Brass Check Valves 1/8" NPT Brass Check Valve Features and Benefits • Poppet style valve incorporates o-ring sealing surface. • Brass body and piston resist corrosion. • Stainless steel spring resists corrosion. • Female NPT threaded connections.
Service and Check Valves Catalog CIC-2003-1/US Notes 130 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Table of Contents TXVs and AXVs Thermostatic Expansion Valves (TXVs) and Constant Pressure (Automatic) Expansion Valves (AXVs) Table of Contents Thermostatic Expansion Valves .................................................................................. page 134 Model Number Selection Guide ............................................................................ page 134 TXVs & AXVs Visual Table of Contents .
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Visual Table of Contents TXVs and AXVs Visual Table of Contents S Series TXV - (page 136) Applications: Air Conditioning, Heat Pumps, Dehumidifiers I Series TXV - (page 137) Applications: Slush Machines, Salad Bars, Vending Machines EG Series TXV - (page 138) Applications: Supermarket Cases, Walk-in Freezers, Ice Machines EGC Series TXV - (page 139) Applications: Supermarket Cases with hot gas defrost, Walk-in Free
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves TXVs and AXVs Visual Table of Contents A7 Series AXV - (page 172) Applications: Ice Cream/Slush Machines, Hot Gas Bypass, Freeze Protection, Refrigerant Reclaim, PTAC/PTHP, High Cycle AS Series AXV - (page 172) Applications: Ice Cream/Slush Machines, Hot Gas Bypass, Freeze Protection, Refrigerant Reclaim, Vending, Ice Machines A1 Series AXV - (page 172) Applications: Ice Cream/Slush Machines, Hot Gas Bypass, Freeze P
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Model Number Selection Guide Thermostatic Expansion Valves TXV Model Number Selection Guide S (E) 5 EXTERNAL EQUALIZER OPTIONAL CAPACITY MODEL V REFRIGERANT (E) for Externally Equalized S EG(C) Evaporator pressure drop > 3 psi C = internal check valve BLANK for Internally Equalized Evaporator pressure drop < 3 psi or smaller tonnage evaporators See page 163 I H(C)(A) C = internal check valve A = adjustable C
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Model Number Selection Guide Thermostatic Expansion Valves 100 CHARGE TYPE M.O.P. B BLEED OPTIONAL 20 BLEED CAPACITY Bleed Capacity Bleed TXVs & AXVs X Calculated based on nominal capacity of valve specified by manufacturer or Parker. Typically 30% or less. Calculated by: Desired Bypass Capacity x 100% Rated Valve Capacity Denoted by “B”. Not available on all TXVs. See bleed capacity.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information S Series S Series Parker’s S series is well suited for new or replacement installations on a variety of small to medium tonnage air-conditioning, heat pump, and refrigeration systems. A brass body with standard ODF solder connections and balanced port construction lends itself to installation on systems requiring stability and control under low load and other varying conditions.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information I Series I Series TXVs & AXVs The right angle I Series with pure copper connections is an ideal compact size brass valve where landscape and precise control is of greatest concern (as in fractional horsepower refrigeration systems). The superheat is factory set to optimize system performance for original equipment applications.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information EG Series EG Series The EG series refrigeration right angle brass body expansion valve incorporates a new shock loop, stainless steel power element, and a removable inlet strainer, making it an ideal choice for commerical refrigeration and supermarket applications. New Rainbow Charges™ are noted below for use on medium temperature (“W” charges), low temperature (“Z” charges) or MOP (“X” charges).
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information EGC Series EGC Series Applications • Hot Gas Defrost • Cool Gas Defrost • Supermarket Cases • Back Shelf Storage Cases • Walk-in Coolers/Freezers • Salad Bars • Transport Refrigeration TXVs & AXVs This valve is similar to the EG series except it incorporates an internal check valve, providing reverse flow up to 2 tons for hot or cool gas defrost applications.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information RE Series RE Series The Parker RE series valve utilizes balanced port construction to provide optimum operation on medium to large tonnage air conditioning and refrigeration systems.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Dimensions RE Series Dimensions RE Body Size 1 TXVs & AXVs Fitting Size RE Body Size 1 ODF A B C D E F G 5/8 1.55 – 0.36 Min – 1.45 2.56 2.06 2.06 2 2 .73 Min. .73 Min. 1.45 2.56 2.3 2.3 .93 Min. .93 Min. 1.45 2.56 2.06 1 3/8 – 2.68 – .93 Min. 1.45 2.56 2.06 Service & Check Valves 7/8 1 1/8 RE Body Size 2 Fitting Size RE Body Size 2 ODF A B C D E F G 1 1/8 2.7 2.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information H and HC Series H Series and HC Series The H series balanced port valve is designed specifically for air conditioning and heat pumps used in both air or water source systems. It offers features such as select indoor and/or outdoor thermostatic Rainbow Charges™, bleeds, and a variety of connection styles for the inlet, outlet, and external equalizer.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Dimensions H and HC Series Dimensions Optional Inlet Screen Available TXVs & AXVs H and& HC Series Dimensions (inches) Connections (ODF) Inlet/Outlet 0.250 0.375 0.500 0.625 0.875 A 1.46 1.69 1.46 1.57 - B 1.46 1.69 1.46 1.57 2.07 Service & Check Valves H and HC Series Connections - flo-rater Inlet - 3/4" - 20 Outlet - 3/4" - 20 Allows reverse flow in heating mode.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information EC Series EC Series The EC series features extended ODF solder connections, brass body, and balanced port design. The new stainless steel power element makes it suited for both refrigeration and air conditioning applications. Rainbow Charges™ are indicated in the chart below for medium temperature “W” charges, low temperature “Z” charges or MOP “X” charge for those applications.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information ECC Series ECC Series TXVs & AXVs The ECC series is similar to the EC series except it incorporates an internal check valve, providing reverse flow of up to 2 tons for hot or cool gas defrost applications. This eliminates the need for an external check valve and related hot gas plumbing. A brass body, ODF solder connections, and a removable inlet strainer make installations easier.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information G Series G Series The G series features a brass body with SAE flare connections and is available internally or externally equalized through a 1/4" SAE male fitting. It provides accurate and stable control over changing loads, and is an ideal selection for refrigeration and air conditioning systems. An array of Rainbow Charges™ provide the necessary control and operation.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information N Series N Series Applications • Low Profile Coolers • Beverage Dispensers • Beverage Boxes • Small Chillers • Ice Machines • Small Freezers TXVs & AXVs This small flare brass valve series is ideally suited where space is at a premium. Its stainless steel power element and compact body has always made it the first choice for installation in commercial refrigeration systems.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Technical Information C Series C Series The C series incorporates a brass body with SAE flare fittings using balanced port construction, allowing operation over varying load conditions. Designed for use on small refrigeration and or air conditioning systems, the external equalized models are provided with a 1/4" SAE male connection.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information B5 Series B5 Series TXVs & AXVs The new Parker B5 series is designed to work with interchangeable orifice cartridges. This choice allows the highest accuracy and the easiest way to select the better flow into the system. A special O-ring seal prevents leakage by the pin (saturated liquid from evaporator inlet) from spraying on the lower side of the power element and affecting valve operation.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information B5 Series Valves Model V-NX100 V-NW JX60 JW SX110 SW Refrigerant R407C R407C R134a R134a R404a R404a May Be Used With R22 R22 R12, R401A, R401B R12, R401A, R401B R125, R502, R402A, R402B, R507 R125, R502, R402A, R402B, R507 Capillary Tube 1500 mm 1500 mm 1500 mm 1500 mm 1500 mm 1500 mm Mop 100 – 60 – 110 Cartridges/Models and Nominal Capacities (kW) Model Cx C0 C1 C2 C3 C4 C5 C6 R22 0.5 1.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Pressure Temperature Chart Thermostatic Expansion Valves Pressure Temperature Chart AZ-50 R-12 R-22 R-123 R-134a R-502 R-507 R-717 6.2 2.7 0.5 2.6 4.9 7.4 10.1 13.2 16.4 20.0 24.0 28.2 32.7 37.7 43.0 48.7 54.9 61.4 68.5 76.0 84.0 92.5 101.6 111.0 121.4 132.0 144.0 156.0 168.4 182.0 196.0 211.0 226.4 243.0 260.0 278.4 296.8 317.0 337.3 359.0 381.0 29.2 29.0 28.9 28.7 28.4 28.1 27.8 27.4 27.0 26.5 25.9 25.3 24.6 23.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Capacity Tables Thermostatic Expansion Valves R134a/R401A*/R401B*/R12* U.S. Extended Capacities in Tons EVAPORATOR TEMP.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Capacity Tables Thermostatic Expansion Valves Liquid Refrigerant Temperature Correction Factor Liquid Line Temp. Multiplier R-134a 50° F 60° F 70° F 80° F 90° F 100° F 110° F 120° F 130° F 140° F Liquid Line Temp. 1.33 1.27 1.21 1.11 1.07 1.00 0.93 0.87 0.81 0.71 Multiplier R-134a 0° C 1.33 20° C 30° C 40° C 50° C 60° C 1.21 1.09 1.00 0.85 0.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Capacity Tables Thermostatic Expansion Valves R22/R407C* U.S. Extended Capacities in Tons Valve Type G(E), EG(E) G(E), EG(E) C(E), EC(E) S(E) G(E), EG(E) I, N G(E), EG(E) C(E), EC(E) S(E) G(E), EG(E) I G(E), EG(E) G(E), EG(E) C(E), EC(E) S(E), N(E) G(E) G(E) C(E), EC(E) S(E) S(E) G(E) S(E) RE RE RE RE RE RE EVAPORATOR TEMP.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Capacity Tables Thermostatic Expansion Valves R22/R407C* Metric Extended Capacities in Kilowatts * See page 160. 7 9 0.75 1.50 2.25 2.25 3.00 3.00 4.50 4.50 4.50 6.00 6.00 7.51 9.01 9.01 9.01 12.00 15.00 15.00 15.00 22.50 24.00 30.00 30.00 45.00 60.00 90.1 120.0 210.0 0.89 1.78 2.66 2.66 3.55 3.55 5.33 5.33 5.33 7.10 7.10 8.88 10.70 10.70 10.70 14.20 17.80 17.80 17.80 26.60 28.40 35.50 35.50 53.30 71.00 107.0 142.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Capacity Tables Thermostatic Expansion Valves R404A/R502*/R402A*, B*/R507* U.S. Extended Capacities in Tons Valve Type G(E), EG(E) G(E), EG(E) G(E), EG(E) C(E), EC(E) S(E) I N G(E), EG(E) C(E), EC(E) S(E) I G(E), EG(E) G(E), EG(E) C(E), EC(E) S(E), N(E) G(E) G(E) C(E), EC(E) S(E) G(E) C(E) RE RE RE RE RE RE EVAPORATOR TEMP.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Capacity Tables Thermostatic Expansion Valves R404A/R502*/R402A*, B/R507* Metric Extended Capacities in Kilowatts * See page 160. 7 9 0.38 0.77 1.53 1.53 1.53 1.53 2.30 3.06 3.06 3.06 3.06 4.59 6.12 6.12 6.12 9.18 12.2 12.2 12.2 18.4 18.4 18.4 27.6 36.7 64.3 91.8 138 0.45 0.91 1.81 1.81 1.81 1.81 2.72 3.62 3.62 3.62 3.62 5.43 7.25 7.25 7.25 10.9 14.5 14.5 14.5 21.7 21.7 21.7 32.6 43.5 76.1 109 163 0.51 1.03 2.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Applications and General Information Thermostatic Expansion Valves Applications Bi-Directional Valves The conventional means of applying thermostatic expansion valves to a split system heat pump is shown in the schematic below.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves General Information Thermostatic Expansion Valves valve will stroke in the closing direction in response to the reduced heat load on the evaporator, again maintaining the proper evaporator outlet superheat. The superheated suction gas flows to the compressor where its pressure and temperature are increased due to compression.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves General Information Thermostatic Expansion Valves evaporator conditions are achieved more rapidly than the all purpose “W” liquid charge. Additionally, the “Z” charge prevents the possibility for compressor floodback on startup due to higher operating superheats at higher evaporator temperatures.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US General Information The Parker Rainbow Charge™ The Parker Rainbow Charge™ Multiple Use Thermostatic Charges for Alternative Refrigerants Charge JW, JX60 (R-134a) VW, VX35, VX100, VZ (R22) SW, SX35, SX110, SZ (R404A) May also be used with R-12, R-401A (MP39), R-401B (MP66) R-407C (AC9000) R-125, R-502, R-402A (HP80), R-402B (HP81), R-507 (AZ50) TXVs & AXVs Parker Rainbow Charges™ are designed to provide precise cont
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves General Information Thermostatic Expansion Valves superheat rises rapidly. As the suction line temperature increases, the bulb pressure will slowly increase and the operating superheat will decrease slowly to the predetermined level. This results in a sawtooth wave form which minimizes the system floodback.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves General Information Thermostatic Expansion Valves TXVs & AXVs Internally Equalized Valves The outlet pressure of an internally equalized valve is transmitted to the underside of the diaphragm through an equalizer hole inside the valve body. Internally equalized valves are used with evaporators that have a pressure drop of less than 3 psi.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves General Information Thermostatic Expansion Valves Off Cycle Unloading (Bleed) Internal bleed orifices are used to equalize the high and low side pressures during the off cycle so that low starting torque compressors can start. Systems such as air conditioners and heat pumps sometimes require a TXV with internal bleed due to the frequent cycling that occurs. Consult the factory if a bypass bleed is required.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Balanced Port Valves Thermostatic Expansion Valves Balanced Port Valves TXVs & AXVs Parker balanced port thermostatic expansion valves can be applied to a broad range of air conditioning and refrigeration systems. They exhibit exceptional performance over a wide variation in load on a specific system, or the same valve can be applied to a large range of application capacities.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Valve Selection Procedure Thermostatic Expansion Valves 2. Determine the required nominal capacity and charge for the valve. Valve Selection Procedure 1. Determine application information. It is important to obtain specific system information in order to choose the correct valve for a particular application.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Valve Selection Procedure Thermostatic Expansion Valves • 3. Choose the valve configuration which best suits the application. • Select a model which best suits the needs of the application based on fitting type, size, and orientation. Consider physical size and type of adjustment available for each model. Determine whether an external equalizer is necessary.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Superheat & Hunting Thermostatic Expansion Valves Tips for Understanding and Preventing Superheat Hunting in TXVs A common problem facing refrigeration and air conditioning service technicians and contractors is that of superheat hunting by thermostatic expansion valves (TXVs). Here is a better understanding of a commonly overlooked cause of superheat hunting and how the problem might be corrected.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Superheat & Hunting Thermostatic Expansion Valves no longer represents an average condition. The suction temperature where the bulb is mounted will be lower than the “true” average of the circuits if they were all properly superheated. Sensing a now “warm” suction condition, the valve opens to decrease superheat and the lightly loaded circuit begins to flood into the suction manifold again.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information Model 104A and 104F Constant Pressure Expansion Valves Model 104A & 104F Constant Pressure Expansion Valves Specifications • Hermetic construction. • Solder connections: High temperature type 1/4" O.D.F. inlet, 3/8" O.D.F. outlet (5/16" outlet available). • Valve opening point adjusting range: 0 to 90 psig is standard for valves. A higher adjustment range is available.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Technical Information Model 139 EPR Model 139 Evaporator Pressure Regulator (EPR) Dimensions TXVs & AXVs Specifications • Solder Connections – 1/4" ODM inlet, 1/4" ODF outlet. • Adjustment Range – Consult Parker. • Adjusting Screw – Set at predetermined pressure with sealant or locknut. • Nominal Capacities – For fractional horsepower compressors. For more detail consult Parker.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Technical Information A Series Constant Pressure (Automatic) Valves A Series Constant Pressure Expansion Valves Specifications • 0-90 psig adjustment range. • Bypass bleeds available. • Construction: Brass, copper and stainless steel. • Optional external equalizer. • U.L. recognized for maximum operating pressure of 500 psig high side, 225 psig low side. Model No.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Technical Information A Series Constant Pressure (Automatic) Valves Model A3 Model AE3 Model A4 TXVs & AXVs Model A2 Service & Check Valves 173 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves U.S. Capacity Tables Constant Pressure (Automatic) and EPR Valves R-134a/R-401A/R-401B/R-12 U.S. Extended Capacities in Tons Evaporator Temp. (°F) Pressure Drop (PSIG) Valve Type Orifice A1, A2, A(E)3, AT B A4 A7-AA AA A7-A A A7-B B A7-C C AS, ASB20 104A .093 104A, 104F .120 104A, 104F .140 Evaporator Temp.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves U.S. Capacity Tables Constant Pressure (Automatic) and EPR Valves R-404A/R-502*/R-402A*, B*/R-507* U.S. Extended Capacities in Tons 75 40°F 100 125 150 175 200 75 20°F 100 125 150 175 200 Nominal Capacity Capacity Range 2 1-2 1.73 2.00 2.24 2.45 2.65 2.83 1.66 1.92 2.15 2.35 1/2 1/4-3/4 0.65 0.75 0.84 0.92 0.99 1.06 0.62 0.72 0.80 0.88 1/2 1/8-1/2 0.43 0.50 0.56 0.61 0.66 0.71 0.42 0.48 0.54 0.59 1 1/4-1 0.87 1.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Metric Capacity Tables Constant Pressure (Automatic) and EPR Valves R-134a/R-401A/R-401B/R-12 U.S. Extended Capacities in Kilowatts Evaporator Temp. (°C) Pressure Drop (BAR) Valve Type Orifice A1, A2, A(E)3, AT B A4 A7-AA AA A7-A A A7-B B A7-C C AS, ASB20 104A .093 104A, 104F .120 104A, 104F .140 Evaporator Temp.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Metric Capacity Tables Constant Pressure (Automatic) and EPR Valves R-404A/R-502/R-402A, B/R-507 U.S. Extended Capacities in Kilowatts Nominal Capacity Capacity Range 7 4-7 3 1-3 2 1/2-2 4 1-4 7 4-7 14 5-14 4 1-4 1 1-4 1 1/4 2-5 1 1/2 3-6 Nominal Capacity Capacity Range 7 4-7 3 1-3 2 1/2-2 4 1-4 7 4-7 14 5-14 4 1-4 1 1-4 1 1/4 2-5 1 1/2 3-6 5 7 6.06 2.27 1.52 3.03 6.06 12.1 3.03 3.03 3.79 4.55 7.17 2.69 1.79 3.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Technical Information Constant Pressure (Automatic) and EPR Valves Understanding the Constant Pressure Valve The constant pressure valve is a vital component of many refrigeration and A/C systems. It automatically meters refrigerant to the evaporator at a rate equal to compressor pumping capacity. The constant pressure valve contains a diaphragm, control spring (FS1), seat and valve needle or ball.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Applications Constant Pressure (Automatic) and EPR Valves Constant Pressure and EPR Valve Applications TXVs & AXVs Constant Evaporator Pressure Parker constant pressure expansion valves maintain a constant evaporator pressure for applications when close control of evaporator pressure and temperature are required.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Applications Constant Pressure (Automatic) and EPR Valves Crankcase Pressure Limiting Parker constant pressure expansion valves can be used to limit the maximum operating suction pressure to the compressor. The valve is adjusted to open at a predetermined outlet pressure while restricting flow at higher system inlet pressures in order to protect the compressor.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Technical Information Thermal Electric Va/ves Model 625 — Thermal Electric Valve Model 625 — Nominal Capacities R-22 - 1/2 through 10 tons R-134a - 1/3 through 7 tons R-404a - 1/3 through 7 tons TXVs & AXVs Specifications • Refrigerant – Can be used with most refrigerants except ammonia. • Voltage – 24 volts AC or DC (in accordance with U.L. low voltage class 2 specifications). • Power – 4.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Applications Thermal Electric Valve Model 625 — Thermal Electric Valves Applications Parker's thermal electric valve can be used for a variety of applications demanding control functions that are difficult to accomplish with thermostatic expansion valves.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Applications Thermal Electric Valves Maintaining a Flooded Evaporator Place the thermistor in an accumulator to control the level of liquid refrigerant. 24 Volts Thermistor Evaporator Compressor Multiple Evaporator Systems The electric valve can increase the efficiency and reduce the number of controls required. Put a 625 valve and thermistor on each evaporator.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Applications Thermal Electric Valves Chillers This chiller design uses the thermistor as a liquid level control and the electric valve as a normal expansion device. 24 Volts Accumulator Thermistor 625 Electric Valve Chiller Compressor Condenser Constant Pressure Control When combined with a pressure or temperature switch, the electric valve can be used to control evaporator pressure.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Operation Thermal Electric Valves Thermal Electric Valve Model 625 Operation Optional Bleed Connnection 625 Electric Valve The operating parts of the valve are shown in the figure at the right. They are: a wire-bound bimetal heater and a spring-loaded needle. Evaporator Coil Condenser Coil The amount of voltage applied to the heater controls the degree of the valve opening. At zero voltage, the valve is closed.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Installation Information Thermal Electric Valves Thermal Electric Valve Model 625 Installation Mounting Position – The valve should be installed such that the thermal head is within 30° of an upright position to insure maximum capacity.
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Installation Information Thermal Electric Valves TXVs & AXVs If the line is at some angle other than vertical, the lower or gravity side is preferable (see the illustration at the right). 5. Thermistor location on horizontal suction lines is more common and in some cases (large diameter low velocity suction lines) permits adjustments to be made in suction gas saturation (see illustration in the right column).
Catalog CIC-2003-1/US Thermostatic and Constant Pressure (Automatic) Expansion Valves Troubleshooting Thermal Electric Valves Troubleshooting Testing For Proper Operation The valve and thermistor should be wired in series as shown in the illustration below. All wiring should be made in accordance with U.L. low voltage class 2 codes. Some Precautions 1. Never apply more than the output of a 24 volt transformer to the valve circuit. 2. Don't apply 24 volts directly across the thermistor leads.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Troubleshooting Thermal Electric Valves Valve Replacement Always replace a defective electric valve with an exact duplicate. Bleed Connection The third solder connection on solder-type electric valves is the bleed connection. It prevents migration of liquid refrigerant to the bimetal chamber. A valve with a bleed tube must always be used on heat pumps.
Thermostatic and Constant Pressure (Automatic) Expansion Valves Catalog CIC-2003-1/US Ratings Thermal Electric Valves Refrigerant R-404a/R-502/R-507C/R-402A,B/R-125 Tons of Refrigeration — Evaporator Temperatures ° F/C +40°F (+4°C) Part Number Orifice Size 75 040925-023 040925-014 040925-013 040925-025 040925-002 040925-003 040925-004 040925-001 040925-005 040925-028 .040 .047 .062 .070 .078 .093 .109 .125 .140 .187 .325 .629 .876 1.04 1.61 2.22 2.71 3.16 3.56 5.
Distributors and Flow Controls Catalog CIC-2003-1/US Table of Contents Distributors and Flow Controls Distributors and Flow Controls Table of Contents Refrigerant Distributors Introduction ......................................................................... page 193 Nozzle Type Distributors .............................................................................................. page 194 Flare Type Distributors with Nozzles ......................................................................
Distributors and Flow Controls Catalog CIC-2003-1/US Notes 192 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Distributors and Flow Controls Catalog CIC-2003-1/US Introduction Refrigerant Distributors Refrigerant Distributors Refrigerant distributors are of two basic designs, each having certain merits that the design engineer may regard as best for the application. Parker produces both basic types with the largest range of sizes, variations and specials of any manufacturer. (Distributors are made of brass unless aluminum is specified.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Nozzle Type Refrigerant Distributors Nozzle Type Distributors Parker nozzle type distributors depend on the high pressure drop through the orifice and the resulting turbulence to provide equal distribution to all circuits. The illustration below shows that the approaching refrigerant streamlines nearest the pipe wall (W), then it turns radial at the face of the nozzle towards the orifice.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Nozzle Type Refrigerant Distributors Distributor Tube Circuit Capacities Table Tube Size inches O.D. 5/32 3/16 1/4 5/16 3/8 40° 0.19 0.40 0.80 1.60 2.80 20° 0.14 0.30 0.60 1.20 2.10 R-12 / R-134a 0° -20° 0.11 0.08 0.23 0.17 0.45 0.33 0.90 0.66 1.60 1.20 -40° 0.06 0.13 0.25 0.50 0.88 40° 0.26 0.53 1.10 2.20 3.70 Evaporating Temperature °F Refrigerant R-22 20° 0° -20° 0.21 0.16 0.12 0.44 0.33 0.24 0.89 0.67 0.49 1.70 1.30 0.
Distributors and Flow Controls Catalog CIC-2003-1/US Nozzle Sizing Table Nozzle Type Refrigerant Distributors Nozzle Sizing Table (Evaporator Temperature, °F) Evaporating Temperature °F Refrigerant Nozzle Number Size 40° 20° 0° -20° -40° 40° 20° 0° -20° -40° 40° 20° 0° -20° -40° 1/2 .35 .28 .22 .18 .16 .62 .48 .37 .28 .25 .40 .31 .22 .17 .13 3/4 .53 .44 .34 .27 .23 .92 .75 .61 .50 .37 .59 .47 .39 .30 .20 1 .72 .56 .47 .36 .30 1.3 1.06 .79 .63 .
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Nozzle Type Refrigerant Distributors Chart A 120 Body Style — 6 Number of Holes Chart A — 1/4 5 Size of Holes Nozzle Size — Chart B Chart B TYPE 107 Maximum No. of Circuits TYPE 107 5/32 7 3/16 6 1604 1/4 4 TYPE 251 5/32 10 3/16 8 1/4 6 1607 5/16 4 197 Nozzle B C D E F .906 1.718 .872 .875 1.000 .375 +/- .015 – 1.156 1.781 .873 .875 .88 .375 +/- .015 8° 1.500 2.437 1.123 1.125 1.125 .375 +/- .
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Flare-Type Distributors with Nozzles Flare-Type Distributors with Nozzles (Regular or Frost Free Nut) Type 23-X-X-X-E60 Maximum No.
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Distributors and Flo-Raters Heat Pump & Hot Gas Defrost Distributors When ordering heat pump and hot gas distributors, specify number and size of side connections. B C D E .623 7/8 63/64 21/32 .625 3/8 G .873 1 or 2 2 35/64 1 1/4 1 7/32 29/32 1/2 .875 Largest 50 3/8 E 1.123 1 or 2 3 1/4 1 5/8 1 15/32 1 1/6 1/2 5/8 1.125 Largest 50 1/2 C 1.373 1 or 2 4 1/4 2 1/4 1 7/8 1 5/16 5/8 7/8 1.375 Largest 50 7/8 A 1.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Venturi Low Pressure Drop Distributors Venturi Low Pressure Drop Distributors This style of distributor is designed on the venturi orifice concept. The venturi orifice has basically three sections: (1) the converging inlet (2) the throat area (3) diverging outlet.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Venturi Low Pressure Drop Distributors 5/32" ODF Distributors Tons - R134a Tons - R22 Tons - R404A/R507 # of Number Outlets 40° 20° 0° -20° -40° 40° 20° 0° -20° -40° 40° 20° 0° -20° -40° 2 0.6 0.41 0.26 0.17 0.12 0.88 0.6 0.4 0.26 0.18 0.45 0.31 0.19 0.12 0.09 3 0.9 0.6 0.4 0.25 0.18 1.32 0.9 0.6 0.39 0.27 0.68 0.46 0.29 0.18 0.13 4 1.2 0.82 0.53 0.34 0.24 1.76 1.2 0.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Venturi Low Pressure Drop Distributors 3/16" ODF Distributors Part Number 3-3-2 *4-3-2 *5-3-2 3-3-3 *4-3-3 *5-3-3 3-3-4 *4-3-4 *5-3-4 3-3-5 *4-3-5 *5-3-5 7-3-5 3-3-6 *4-3-6 *5-3-6 7-3-6 3-3-7 *4-3-7 *5-3-7 7-3-7 *4-3-8 *5-3-8 7-3-8 9-3-8 4-3-9 *5-3-9 7-3-9 9-3-9 *5-3-10 7-3-10 9-3-10 7-3-11 9-3-11 *5-3-12 7-3-12 9-3-12 F5-3-13 7-3-13 9-3-13 7-3-14 9-3-14 7-3-15 9-3-15 7-3-16 9-3-16 7-3-17 9-3-17 7-3-18 9-3-18 7-3-19 9-3-19 7-3-20
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Venturi Low Pressure Drop Distributors 1/4" ODF Distributors # of Outlets 40° Tons - R134a 20° 0° -20° -40° 40° 20° 2 2.4 1.7 1.1 .70 .50 3.5 2.4 1.6 3 3.6 2.4 1.7 1.1 .76 5.3 3.6 4 4.8 3.2 2.2 1.4 1.0 7.0 5 6.0 4.1 2.8 1.8 1.3 6 7.2 4.9 3.2 2.2 7 8.4 5.8 3.8 8 9.6 6.5 9 10.8 10 Tons - R22 0° -20° 40° Tons - R404A/R507 20° 0° -20° -40° 1.1 .76 1.8 1.3 .81 .54 .37 2.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Venturi Low Pressure Drop Distributors 5/16" ODF Distributors Part Number *4-5-2 *5-5-2 7-5-2 F4-5-3 *5-5-3 7-5-3 F4-5-4 *5-5-4 7-5-4 7-5-5 9-5-5 7-5-6 9-5-6 9-5-7 11-5-7 9-5-8 11-5-8 11-5-9 11-5-10 11-5-11 11-5-12 11-5-13 11-5-14 11-5-15 13-5-16 13-5-17 13-5-18 13-5-19 13-5-20 13-5-21 13-5-22 # of Outlets 40° Tons - R134a 20° 0° -20° -40° 40° 20° Tons - R22 0° -20° -40° 40° Tons - R404A/R507 20° 0° -20° -40° 2 4.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Venturi Low Pressure Drop Distributors 3/8" ODF Distributors Tons - R134a Tons - R22 Tons - R404A/R507 Part # of Number Outlets 40° 20° 0° -20° -40° 40° 20° 0° -20° -40° 40° 20° 0° -20° -40° F4-6-2 2 8.4 5.8 3.8 2.5 1.8 12.3 8.3 5.5 3.7 2.6 6.3 4.3 2.9 1.9 1.4 3 12.6 8.5 5.6 3.8 2.6 18.4 12.5 8.3 5.5 3.9 9.5 6.4 4.2 2.9 2.0 4 16.8 11.4 7.6 5.0 3.5 24.5 16.7 11.1 7.
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Type 3-3-2 A Dia. Venturi Low Pressure Drop Distributors B Dia. C D +/-.015 Example of Type Number F 3-3-3 3-3-4 .812 1.236 .171 .393 1.000 1.380 .171 .375 3 – 3 – 4 Size of Size of Number Inlet in Outlets in of 1/8ths 1/16ths Outlets 3-3-5 3-3-6 3-3-8 .375 .373 3-4-2 3-4-3 .812 3-4-4 1.236 .234 .393 3-4-6 Type 5-4-2 5-4-3 5-4-5 – .708 – .625 .909 .500 4-2.5-6 .688 1.022 .505 4-2.5-8 .
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Type A Dia. 7-4-9 Venturi Low Pressure Drop Distributors B Dia. 1.416 7-4-10 C D +/-.015 F 2.247 9-5-8 9-6-5 7-4-12 1.701 2.698 1.800 2.698 2.188 7-4-17 3.550 .234 .880 2.109 1.415 2.328 1.500 2.458 1.688 2.779 11-4-14 1.183 2.995 11-4-15 1.875 3.119 11-4-16 1.988 3.296 2.180 3.582 2.313 4.015 2.705 4.138 1.484 2.218 1.938 3.033 2.313 3.649 1.484 2.239 1.890 2.671 2.296 3.239 1.468 2.
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Flare Type Venturi Distributors Flare Type Venturi Distributors Regular or Frost Free Nut Outlet Number Size of Outlets 3 4 3/16 5 6 2 4 5/32 5 6 8 2 3 4 3/16 5 6 8 2 3 1/4 4 5 6 2 5/16 3 3/8 2 Type Number F3-3-3 F3-3-4 F3-3-5 F3-3-6 F4-2.5-2 F4-2.5-4 F4-2.5-5 F4-2.5-6 F4-2.5-8 F4-3-2 F4-3-3 F4-3-4 F4-3-5 F4-3-6 F4-3-8 F4-4-2 F4-4-3 F4-4-4 F4-4-5 F4-4-6 F4-5-2 F4-5-3 F4-6-2 A B Dia.
Distributors and Flow Controls Catalog CIC-2003-1/US Dimensions Flo-Rater Designs Parker Plus: Value-Added Components & Custom Brazing Parker Climate Controls Division produces up to 20 million trouble-free braze joints a year for HVAC/R companies worldwide. Our customers have discovered that Parker brazed products offer greater integrity which results in lower on-line leaks and fewer field problems.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical and Ordering Information Flo-Rater Style F Flo-Rater Style F Application Meter refrigerant and distribute two-phase refrigerant to a coil. Replaces capillary tubes, TXVs and check valves as a means of metering refrigerant flow through air conditioning and heat pump systems. Features and Benefits • Most versatile and cost effective body style. • Accepts 5 fluted, 3 fluted and double-headed piston styles. • Accepts TVXs — no brazing required.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical and Ordering Information Flo-Rater Style A Flo-Rater Style A Application Meter refrigerant and distribute two-phase refrigerant to a coil. Replaces capillary tubes, TXVs and check valves as a means of metering refrigerant flow through air conditioning and heat pump systems. Agency Approvals UL Recognized; File No: 7511 Distributors & Flow Controls Features and Benefits • Cost effective. • Full range of circuit sizes and quantities.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical and Ordering Information Flo-Rater Style FD20 Flo-Rater Style FD20 Application Meter refrigerant and distribute two-phase refrigerant to a coil. Replaces capillary tubes, TXVs and check valves as a means of metering refrigerant flow through air conditioning and heat pump systems. Features and Benefits • Cost effective. • Full range of circuit sizes and quantities. • Easy field replaceable restrictor — no brazing required.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical and Ordering Information Flo-Rater Style M Flo-Rater Style M Application Meter refrigerant and distribute two-phase refrigerant to a coil. Replaces capillary tubes, TXVs and check valves as a means of metering refrigerant flow through air conditioning and heat pump systems. Distributors & Flow Controls Agency Approvals UL Recognized; File No: 115500 Features and Benefits • Heavy duty design. • Full range of circuit sizes and quantities.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Flo-Rater Style FD20D and FD20E Flo-Rater Style FD20D Application Designed to replace hard-to-handle and easily damaged capillary tubing giving a more predictable pressure drop. Agency Approvals UL Recognized; File No: 2709 Features and Benefits • Cost effective alternative to capillary tubes. • One piece design. • Versatility in length, end configuration, orifice size and copper tube bend configuration.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Flo-Rater Style FD20F Flo-Rater Style FD20F Application Utilizing a floating orifice the FD20F is designed for use on PTAC systems. This eliminates hard-to-handle and easily damaged capillary tubing and check valves giving a more predictable pressure drop. Features and Benefits • Cost effective alternative to capillary tubes. • One piece design. • Bi-directional flow with filter screen combination. • Custom end configurations.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Manifolds Manifolds Application Meter refrigerant and distribute two-phase refrigerant to a coil. Replaces capillary tubes, TXVs and check valves as a means of metering refrigerant flow through air conditioning and heat pump systems. Features and Benefits • Custom manifolds are available for optimizing evaporator and condensor coil performance.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical and Ordering Information Flo-Rater and Manifold Pistons Flo-Rater and Manifold Pistons Orifice Sizing See graphs on page 218. Piston Style: 5 Fluted (5) Nomenclature Applications Use in body style F, A and M No. 5OPXXX0 (Example) 059 — — 0 Distributors & Flow Controls 5OP Orifice Diameter in Thousandths Piston Style: 3 Fluted (3) Nomenclature Applications Use in body style F, A and M No.
Catalog CIC-2003-1/US Distributors and Flow Controls Technical Information Flo-Raters and Manifolds Selecting the Right Orifice for Your Flow Control You can use the following graphs to select the correct flow control for your applications: 1) Determine the amount of subcooling desired. 2) Select the graph closest to desired subcooling. 3) Determine design inlet pressure = p. 4) From the selected graph, choose the line with the appropriate pressure. 5) Determine the required mass flow.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information O-Ring Adapter Fittings O-Ring Adapter Fittings Features and Benefits • Variations of length and tube connetions available. Dimensions Distributors & Flow Controls Size Brazed End .500 .625 .750 .875 .625 .875 .750 .875 1.000 1.125 1.125 1.375 22-20 1.375 Dash Size 8-10 10-10 12-10 14-10 10-12 14-12 12-16 16-14 16-16 18-16 18-20 O.D. Tube Size .625 .625 .625 .625 .750 .750 1.000 1.000 1.000 1.000 1.250 1.375 1.250 A ±.010 1.
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Type-O Fittings Type-O Fittings Features and Benefits • Modifications of these fittings are available upon request. • Add suffix “A” for aluminum, “S” for steel. Male Inverted Swivel Nut Tube (O-Type) Material: Brass Dimensions Part No. 4053 4075 Thread Size 7/16-24 NS-2A 5/8-18 UNF-2A Min. Full Thread .286 .356 Tube O.D. .250 .375 A Hex. .44 .62 B Dia. Max. Min. .258 .255 .383 .380 C Dia. Max. Min. .378 .363 .548 .
Distributors and Flow Controls Catalog CIC-2003-1/US Technical Information Distributors and Flo-Raters Female Fitting Tube (O-Type) Material: Brass Dimensions Distributors & Flow Controls Thread Size 7/16-20 UNF-2B 5/8-18 UNF-2B 3/4-16 UNF-2B 7/8-14 UNF-2B 1-1/16-14 UNF-2B Min. Full Thread .22 .26 .32 .42 .54 Tube O.D. .250 .375 .500 .625 .750 A Hex. .56 .75 .88 1.06 1.25 FDIA Max. Min. .260 .255 .385 .380 .510 .505 .635 .630 .760 .755 C .38 .44 .50 .68 .81 221 D .12 .12 .12 .12 .12 E Dia. .
Distributors and Flow Controls Catalog CIC-2003-1/US Notes 222 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Value-Added Products and Services Catalog CIC-2003-1/US Table of Contents Value-Added Products and Services Value-Added Products and Services Table of Contents Value-Added Products and Services .......................................................................... page 225 Also see pages 4 and 5 for value-added products and services.
Value-Added Products and Services Catalog CIC-2003-1/US Notes 224 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Value-Added Products and Services Catalog CIC-2003-1/US Technical Information Value-Added Assemblies Value-Added Assemblies Parker can add value to your units by creating unique assemblies designed to your specifications. Our manufacturing and assembling processes create value-added assemblies that include components and custom-bent tubing to match the unique design of a unit.
Value-Added Products and Services Catalog CIC-2003-1/US Notes 226 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Table of Contents Refrigeration Solenoid Valves Refrigeration Solenoid Valves Table of Contents General Information ..................................................................................................... page 229 Introduction ............................................................................................................. page 229 Nomenclature, Ordering Information & Standard Voltages ................................
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Notes 228 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Introduction General Information Introduction • High pressure ratings to comply with newer refrigerants. • Extended end sweat connections enable brazing installation without disassembly. • Complete line of high temperature watertight coil designs suitable for all valves. • AC & DC coils are interchangeable on all valve body versions.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Ordering Instructions & Standard Voltages General Information Solenoid Valve Nomenclature The numbering system allows every user an easy method to identify, select and understand the valve being purchased.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US General Specifications General Specifications General Specifications Refrigerants ............ R-22, R-134a, R-404a, R-507, etc. Maximum Safe Working Pressure ...................... 650psi Operating Temperature Range Fluid .................................................. -20°F to 250°F (-30°C to 121°C) (10w ac) Ambient for AC voltages ................... -20°F to 120°F (-30°C to 49°C) Ambient for DC voltages ...................
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Ratings Summary General Specifications Ratings Summary Valve Series* R10/15 E2 & R10/15 E3 & R20/25 E4 & R20/25 E6 & R20/25 E8 & R30/35 E10 R30/35 E12 R30/35 E15 R40/45 E18 R40/45 E28 R50/55 E32 R50/55 E40 R22 0.73 1.18 2.09 3.8 5.53 8.42 10.8 16.2 24.9 44.0 69.2 120.7 Liquid R404a R134a R507 0.56 0.49 0.91 0.79 1.62 1.41 2.95 2.56 4.29 3.73 6.53 5.67 8.38 7.27 12.5 10.9 19.3 16.7 34.1 29.6 53.7 46.6 93.6 81.3 R410a 0.87 1.4 2.49 4.53 6.61 10.1 12.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Series R10 and R15 Direct Acting Valves Series R10 — 2-Way Direct Acting Normally Closed Valves Series R15 — 2-Way Direct Acting Normally Open Valves Materials of Construction Body ..................................................................... Brass Seals .................................................................. Rulon® Plunger .................................................... 430 Stainless Sleeve Tube ..........
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Call-Outs Series R10 and R15 Direct Acting Valves Call-Outs R10M R15 234 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Series R10 and R15 Direct Acting Valves Dimensions Dimensions .87 2.66 1.62 1.78 7/8 Dia Knockout for 1/2" Conduit Connection 2 places 1.87 1.75 Coil Removal 2.75* 1.98* .30 Outlet A .63 ∅1.25 2.05 Connection 1/4 ODF 3/8 ODF Dimension “A” ± .125 4.62 5.00 Manual override components and body features are shown for manual override valve option only. *Add 0.19 for normally open R15 valve.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Series R20 and R25 Pilot-Operated Valves Series R20 — 2-Way Pilot-Operated Normally Closed Valves Series R25 — 2-Way Pilot-Operated Normally Open Valves Materials of Construction Body ..................................................................... Brass Seals .................................................................. Rulon® Plunger .................................................... 430 Stainless Sleeve Tube .......
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Call-Outs Series R20 and R25 Pilot-Operated Valves Call-Outs R20M Refrigeration Solenoid Valves R25 237 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Dimensions Series R20 and R25 Pilot-Operated Valves Dimensions 2.66 .87 1.62 1.78 7/8 Knockout For 1/2" Conduit Connection 2 PLCS 1.87 1.75 Coil Removal 2.57 3.19 2.05 Inlet .32 .57 Outlet ∅1.25 1.42 A R20 Valve Shown Connection 1/4 ODF 3/8 ODF 1/2 ODF Dimension “A” ± .125 4.62 5.00 5.00 Manual override components and body features are shown for manual override valve option only.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Series R30 and R35 Direct Acting Valves Series R30 — 2-Way Pilot-Operated Normally Closed Valves Series R35 — 2-Way Pilot-Operated Normally Open Valves Materials of Construction Body ..................................................................... Brass Seals .................................................................. Rulon® Plunger .................................................... 430 Stainless Sleeve Tube ........
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Call-Outs Series R30 and R35 Direct Acting Valves Call-Outs R30M R35 240 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Dimensions Series R30 and R35 Direct Acting Valves Dimensions 2.66 1.53 .47 1.78 7/8 Knockout For 1/2" Conduit Connection 2 PLCS 1.87 1.75 Coil Removal 3.71* 2.20* 3.76* .74 Outlet Inlet 1.36 1.34 1.83 Refrigeration Solenoid Valves 1.00 #8-32 UNC-2B Thread 2 PLCS A R30 Valve Shown Connection 3/8 ODF 1/2 ODF 5/8 ODF 7/8 ODF Dimension “A” ± .125 4.62 5.00 5.50 7.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Series R40 and R45 Pilot-Operated Valves Series R40 — 2-Way Pilot-Operated Normally Closed Valves Series R45 — 2-Way Pilot-Operated Normally Open Valves Materials of Construction Body ..................................................................... Brass Seals .................................................................. Rulon® Plunger .................................................... 430 Stainless Sleeve Tube .......
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Call-Outs Series R40 and R45 Pilot-Operated Valves Call-Outs R40M Refrigeration Solenoid Valves R45 243 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Dimensions Series R40 and R45 Pilot-Operated Valves Dimensions 2.75 1.78 .85 2.66 1.75 Coil Removal 1.87 7/8 Knockout For 1/2" Conduit Connection 2 PLCS 2.60* 4.72* Outlet 4.78* Inlet 1.36 2.23 1.72 2.86 1.00 #8-32 UNC-2B Thread 2 PLCS A Connection 5/8 ODF 7/8 ODF 1-1/8 ODF 1-3/8 ODF Dimension “A” ± .125 7.12 7.12 8.50 11.06 Manual override components and body features are shown for manual override valve option only. * Add 0.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Series R50 and R55 Direct Acting Valves Series R50 — 2-Way Pilot-Operated Normally Closed Valves Series R55 — 2-Way Pilot-Operated Normally Open Valves Materials of Construction Body ..................................................................... Brass Seals .................................................................. Rulon® Plunger .................................................... 430 Stainless Sleeve Tube ........
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Call-Outs Series R50 and R55 Direct Acting Valves Call-Outs R50M R55 246 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Dimensions Series R50 and R55 Direct Acting Valves Dimensions 2.66 3.85 1.78 1.19 7/8 Dia Knockout for 1/2" conduit connection 2PLCS 1.75 Coil Removal 1.87 2.95* 5.51* 5.45* Outlet 1.73 Inlet 2.97 Refrigeration Solenoid Valves 3.93 2.06 1.50 1/4-20 UNC-2B Th'd 2 PLCS *Add 0.19 for normally open R55 valve. A Connection 1-1/8 ODF 1-3/8 ODF 1-5/8 ODF 2-1/8 ODF 2-5/8 ODF Dimension “A” ± .125 8.50 11.06 11.06 11.06 11.
Catalog CIC-2003-1/US Refrigeration Solenoid Valves Technical Information Electrical Specifications Electrical Specifications trates which wires to connect to each other for 120 or 240 volt operation. Wiring and fusing must comply with prevailing local and national wiring codes and ordinances. All Parker Refrigeration solenoid valves use standard coil designs that are interchangeable on all valve bodies. They are available in a wide variety of standard voltages and frequencies.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Coil Enclosures Coil Enclosures Standard Features • Suitable for all Parker Refrigeration Solenoid Valves. • Encapsulated Waterproof designs. • Meets UL, CSA, NEMA & other acceptable standards. • • • • Dual Frequency coil for AC voltages. Dual Voltage coils available. Easy installation with nut and washer. UL and CSA approvals on “R” Series valves with applicable “R” coil/enclosure combinations.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information 3-Way Hot Gas Defrost Valves 3-Way Hot Gas Defrost Valves Pilot Port Plunger RS65 Piston Suction Line RS55, RS65 Discharge Line RS70 Evaporator Line Discharge Line RS55 & Suction Line RS70 Piston Integral Bypass Tube Application Designed for hot gas defrost from the suction side of the evaporator coil, these valves are commonly used with modern multiplex systems.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information 3-Way Hot Gas Defrost Valves General Specifications for Refrigerant Solenoid Valves Minimum Operating Pressure Differential ......................... 10 psi (.7 bars) Maximum Opening Pressure Differential ...................... 300 psi (21 bars) (Discharge to Evaporator) Design Pressure (SWP) .................................. 500 psig Operating Temperatures Fluid ................................................
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Extended Capacity Tables Extended Capacity Tables R22 Valve Series R10/15 E2 R10/15 E3 & F3 R20/25 E4 & F4 R20/25 E6 & F6 R20/25 E8 & F8 R30/35 E10 R30/35 E12 R30/35 E15 R40/45 E18 R40/45 E28 R50/55 E32 R50/55 E40 1 psi 0.42 0.68 1.21 2.19 3.19 4.86 6.23 9.33 14.40 25.40 39.90 69.70 Liquid Capacitities Suction Line Capacities Tons at Pressure Drop Across Valve in psi 2 psi 3 psi 4 psi 0.59 0.73 0.83 0.96 1.18 1.35 1.71 2.09 2.40 3.10 3.80 4.35 4.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Extended Capacity Tables Extended Capacity Tables (Continued) R404a and R507 Liquid Capacitities Valve Series R10/15 E2 R10/15 E3 & F3 R20/25 E4 & F4 R20/25 E6 & F6 R20/25 E8 & F8 R30/35 E10 R30/35 E12 R30/35 E15 R40/45 E18 R40/45 E28 R50/55 E32 R50/55 E40 1 psi 0.28 0.46 0.81 1.48 2.15 3.27 4.20 6.28 9.66 17.10 26.90 46.90 Suction Line Capacities Tons at Pressure Drop Across Valve in psi 2 psi 3 psi 4 psi 5 psi 0.40 0.49 0.56 0.63 0.65 0.79 0.90 1.
Catalog CIC-2003-1/US Refrigeration Solenoid Valves Operating Principles Technical Information Operating Principles Introduction Solenoid valves are highly engineered products which can be used in many diverse and unique system applications. This section provides a brief overview of the components and functional varieties of solenoid valves. General Information Valve Construction and Basic Operation A solenoid valve is an electronically operated device.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Design Terminology, Identification and Agency Approvals Technical Information Design Terminology Continuous Duty – A rating given to a valve that can be energized continuously without overheating. Correction Factor – A mathematical relationship related to a fluids specific gravity used to convert specific flows from a standard media to the media in question.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Typical Applications Typical Applications Evaporator Temperature Control Defrost Pump Down A solenoid valve installed in the liquid line as close to the evaporator as possible, in conjunction with a narrow differential thermostat, is an excellent temperature control. By mounting the thermostat bulb in the supply or discharge air across the evaporator, the temperature swing is limited only by the differential of the thermostat.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Typical Applications Split Evaporator — Humidity Control There are often times when the air temperature is satisfactory but the humidity level is too high. This can be remedied by using only half the evaporator to dehumidify the air without excessive cooling and the addition of auxiliary heat. This can best be accomplisehd by using a normally open solenoid valve on one half of the evaporator controlled by a humidistat.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Typical Applications Capacity Control System Hot Gas Defrost System This system is drawn with only two evaporators but it is recommended that only twenty-five percent of any multiplexed system be hot gas defrosted at any given time. An alternative to the hot gas defrost system is the cool gas defrost which uses the gas from the top of the receiver to defrost the evaporators.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Pulse Width Modulating Valves Pulse Width Modulating Valves Parker’s pulse width solenoid valves are designed to meter the refrigerant flow of mechanical refrigeration systems.
Catalog CIC-2003-1/US Refrigeration Solenoid Valves Typical Applications Pulse Width Modulating Valves Typical Applications Superheat Control Using appropriate temperature sensors, the temperature difference between the inlet and outlet of the evaporator will define a temperature which is related directly to superheat. Flooding is present if the temperature difference is zero. Adjustments to actual superheat must be made when the system has large evaporator pressure drops.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Pulse Width Modulating Valves HP Series Model HP Mechanical Specifications Safe Working Pressure .................................. 500 PSIG Burst Pressure ............................................. 2500 PSIG Operating Pressure Differential ........... See table below Operating Temperature ........................ -20° F to +240° F Storage Temperature ......................................... +180° F Capacities ................
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Capacity Tables R-12 US Extended Capacities in MBTU/H Valve Type HP120 HP130 HP145 HP160 CS1073 CS1085 DS1100 DS1120 Evaporator Temp. °F Pressure Drop (PSIG) 40 60 Orifice 1/64 0.68 0.84 1/32 1.20 1.47 3/64 2.47 3.02 1/16 4.14 5.06 5/64 7.23 8.86 3/32 9.40 11.51 7/64 11.57 14.16 1/8 13.13 16.08 40° 0° 80 100 120 140 0.97 1.70 3.49 5.85 10.23 13.29 16.36 18.57 1.08 1.90 3.90 6.54 11.43 14.86 18.29 20.76 1.18 2.08 4.27 7.16 12.52 16.28 20.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Solenoid Valves for Secondary Coolants Solenoid Valves for Secondary Coolants For Supermarket Refrigeration Description Parker Hannifin, a pioneer in supermarket refrigeration control, introduces a new line of solenoid valves to control secondary coolants. These fluids include propylene glycol, ethylene glycol, Pecasol 50, Dynalene HC-40, and others.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Solenoid Valves for Secondary Coolants General Specifications Valve Description: 2 way hung diaphragm normally closed valve with brass forged body and EPDM trim material Valve Maximum Fluid Temperature ............... -40° F to +180° F (-40° C to +82° C) Valve Body ............................................... Forged brass Connections ............................................. ODF Copper Plunger and Pole Piece ...............
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Jackes-Evans Refrigeration Solenoid Valves (RB/ORB Series) Note: Parker Jackes-Evans refrigeration solenoid valves are being discontinued. For all new applications, see pages 229-262 of this catalog for new and improved R Series refrigeration solenoid valves. See page 267 for the R Series/ Jackes-Evans Cross Reference chart.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Jackes-Evans Refrigeration Solenoid Valves When the coil is de-energized, the pilot orifice is closed. The inlet pressure through the equalizer orifice equalizes the pressure above and below the diaphragm. The diaphragm resets, closing the valve. MOPD (Maximum Opening Pressure Differential) The MOPD between the inlet and outlet pressure of the valve must not be exceeded or the valve will not open.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Jackes-Evans Refrigeration Solenoid Valves R Series Refrigeration Valves Cross Reference Chart (to former Jackes-Evans RB Series Valves) Port / Orifice Size 0.078 3/32 1/8 3/16 1/4 0.315 0.375 0.468 0.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Jackes-Evans Refrigeration Solenoid Valves 1 to 9 Tons (Normally Closed) RB1E3 RB3F2 Valve Series R-12 R-22 RB1 1.0 1.0 RB3 3.5 RB6 RB9 RB6E4 Nominal Capacity (Tons)* R-502 R-134a 1.0 1.0 9.3 R-507/R-404a** 1.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Jackes-Evans Refrigeration Solenoid Valves 10 to 83 Tons (Normally Closed) RB15E5 Valve Series R-12 RB15 14 RB21 23 RB41 R-22 Nominal Capacity (Tons)* R-502 R-134a 83 R-507/R-404a** Model Number RB15E5 RB15ME5 RB15E7 RB15ME7 RB15E9 RB21E7 RB21ME7 RB21E9 RB21ME9 RB41E9 RB41ME9 RB41E11 RB41ME11 RB81E13 RB81ME13 RB81E17 RB81ME17 Port Size Connection Size 5/8" ODF 5/8" ODF 7/8" ODF 7/8" ODF 11/8" ODF 7/8" ODF 7/8" ODF 11
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Technical Information Jackes-Evans Solenoid Valves 1 to 83 Tons (Normally Open) ORB3F3 ORB6E5 Valve Series R-12 R-22 ORB1 1.0 1.0 ORB3 3.5 ORB6 6.0 ORB9 9.3 ORB15 ORB21 ORB41 ORB81 ORB41E9 Nominal Capacity (Tons)* R-502 R-134a 1.0 1.0 1.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Electrical Characteristics Junction Box Jackes-Evans Refrigeration Solenoid Valves Conduit Boss All Jackes-Evans RB Series Solenoid Valves use the same size coil regardless of the valve type or style. They are available in a wide variety of voltages and frequencies in addition to the standard coils, listed in the table below. Coils are labeled with electrical data providing easy identification.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Capacity Tables R-12 R-22 R-502 R-134a R-507 & R-404a Model Number RB1 RB3 RB6 RB9 RB15 RB21 RB41 RB81 RB1 RB3 RB6 RB9 RB15 RB21 RB41 RB81 RB1 RB3 RB6 RB9 RB15 RB21 RB41 RB81 RB1 RB3 RB6 RB9 RB15 RB21 RB41 RB81 RB1 RB3 RB6 RB9 RB15 RB21 RB41 RB81 Jackes-Evans Refrigeration Solenoid Valves Liquid Line Capacities1 1 psi 0.53 2.40 4.30 6.60 10.00 16.00 26.00 59.00 0.69 3.00 5.10 8.60 13.00 20.00 33.00 76.00 0.47 2.10 4.10 5.80 8.90 14.00 22.00 51.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Dimensions Extended End Sweat (ODF) Jackes-Evans Refrigeration Solenoid Valves NPT Typical End View SAE Flare All Dimensions in Inches Centerline to end of Mounting Mounting Inside Junction Maximum Hole Hole Thread Lay-in Box Width Centerline Dimensions Length G H J K L 2.59 1.88 0.75 8-32 N.A. 2.59 1.88 0.75 8-32 N.A. 2.59 1.88 0.75 8-32 3.94 2.59 1.88 0.75 8-32 3.94 2.59 1.88 0.75 8-32 N.A. 2.59 1.88 0.75 8-32 N.A. 2.59 1.88 0.75 8-32 N.A. 2.59 1.
Refrigeration Solenoid Valves Catalog CIC-2003-1/US Notes 274 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
General Purpose Solenoid Valves Catalog CIC-2003-1/US Table of Contents General Purpose Solenoid Valves General Purpose Solenoid Valves Table of Contents Two-Way Solenoid Valves ............................................................................................ page 277 Three-Way Solenoid Valves ......................................................................................... page 278 Four-Way Solenoid Valves ..............................................................................
General Purpose Solenoid Valves Catalog CIC-2003-1/US Notes 276 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Two-Way Solenoid Valves Two-Way Solenoid Valves Series 20: 1/8" – 3/8" NPT connections, 3/64" – 9/32" orifice • Pressures from 0-2200 psi depending on orifice size and operation • UL Listed and CSA Certified • Normally open or normally closed, direct acting • Brass or stainless steel (303ss for 1/8" and 1/4" NPT, 316ss for 3/8" NPT) • Buna-N, Viton ® , Neoprene, Ethylene propylene or Teflon® seals • AC or DC voltage • NEMA 1, 2,
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Three-Way and Four-Way Solenoid Valves Three-Way Solenoid Valves Series 30: 1/8" – 1/4" NPT connections, 3/64" – 11/64" orifice • Pressures from 0-250 psi depending on orifice size and operation • UL Listed and CSA Certified • Normally open, normally closed, or universal construction • Direct acting • Brass or 303 stainless steel • Buna-N, Viton ® , Neoprene, Ethylene propylene or Teflon® seals • AC or DC voltage • NEMA 1, 2, 3,
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Special Purpose Valves Special Purpose Valves Designed for Specific Applications Cryogenic Valves: 1/8" – 1" NPT connections, 3/64" – 1" orifice • Pressures from 0-500 psi depending on construction • 2-way, normally closed or normally open • Brass or 303 stainless steel depending on construction • For liquid CO 2 and other cryogenic fluids to -320°F (-196°C) • Teflon ® or urethane standard seals; Kel-F seal for bubbletight shuto
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Gold Ring™ General Purpose Industrial Solenoid Valves Gold Ring™ General Purpose Industrial Solenoid Valves Applications Parker's Gold Ring™ line of brass body general purpose solenoid valves include the two, three and four-way products for use in a variety of applications. The valves are used in situations where the need exists to electrically control the flow of a fluid or gas.
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Gold Ring™ General Purpose Industrial Solenoid Valves Two-Way Steam & Hot Water Solenoid Valves Operating Pressure Differential Max. (MOPD) PSI Air Min. Inert Gas Water NPT Orifice Cv PSI Notes Operation: Steam & Hot Water Two-Way Normally Closed (Energize to Open) 3/8 1/2 1/2 1/2 3/4 3/4 3/4 1/2 1/2 1/2 5/8 3/4 3/4 3/4 3.00 3.6 3.6 4.00 7.4 7.4 5.00 1 1 1 0 1 1 0 50 50 125 50 50 125 50 150 150 2,4 2,4 3 4 2,4 3 4 Max.
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Water Regulating Valves Water Regulating Valves Features • Compact size simplifies installation. • Self-cleaning – sliding block wipes orifice clean every cycle. • Easy to adjust – Simple screw type pressure adjustment. Adjusting stem is easily accessible. • Diaphragm type nitrile seals keep water in main valve body. Water does not come in contact with either spring or bellows. Elastomer seals are nylon reinforced.
General Purpose Solenoid Valves Catalog CIC-2003-1/US Technical Information Dual Acting Water Valves Dual Acting Water Valve Features • Does the Work of Two Valves — The Model 265 handles both the heating and cooling cycles of water source heat pumps so that a separate valve for each cycle is unnecessary. As a result, cost is reduced, efficiency increased, and maintenance simplified.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Table of Contents Flo-Con Pressure Regulators and Valves Flo-Con Pressure Regulators and Valves Table of Contents Product Overview ......................................................................................................... page 286 (S)PORT and (S)PORT-II Evaporator Pressure Regulators ....................................... page 288 A8, (S)PORT and SC Suction Capacities ............................................................
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Product Overview Flo-Con Pressure Regulators and Valves Product Overview With more than 30 years of commercial refrigeration control valve design and manufacturing experience, the Parker Refrigerating Specialties product line has evolved to include a wide variety of regulators, solenoid valves, and in-line check valves designed for precise and reliable control in both supermarket and field built halocarbon systems.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Product Overview Flo-Con Pressure Regulators and Valves regulator combined with an electric shut-off feature, or (S)PORT, and a unique combination of electric shut and bypass feature, the (S)PORT-B.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information (S)PORT Evaporator Pressure Regulators (S)PORT and (S)PORT-II Evaporator Pressure Regulators Features and Benefits • Highest capacity commercial regulator in the industry. • Sweat-in-place without disassembly. • Interchangeable capacity cartridges. • Low pressure drop. • Manual opening stem. • Variations include electric shut-off along with bypass and shut-off feature.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information (S)PORT Evaporator Pressure Regulators Description: Unlike other Parker Refrigerating Specialties regulators, (S)PORT regulators utilize a unique numbering system identifying port & connection size values in eighths of an inch (see previous page).
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Tons) Evap Temp °F Evap Pres. psig 50° F 84 psig 40° F 68.5 psig 30° F 54.9 psig 20° F 43.0 psig 10° F 32.7 psig 0° F 23.9 psig -10° F 16.4 psig -20° F 10.1 psig -30° F 4.8 psig -40° F 0.5 psig Pres Drop psi 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 03 3/8" 9 mm 0.74 1.26 1.59 2.15 0.67 1.14 1.44 1.92 0.61 1.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Kilowatts) Evap Temp °C Evap Pres. Bar 10° C 5.8 bar 5° C 4.8 bar 0° C 4 bar -5° C 3.2 bar -10° C 2.6 bar -15° C 1.98 bar -20° C 1.46 bar -25° C 1.0 bar -30° C 0.63 bar -40° C 0.04 bar Pres Drop bar 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Tons) Evap Temp °F Evap Pres. psig 50° F 45.4 psig 40° F 35.1 psig 30° F 26.1 psig 20° F 18.4 psig 10° F 11.9 psig 0° F 6.5 psig -10° F 2.0 psig Pres Drop psi 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 03 3/8" 9 mm 0.58 0.97 1.21 1.57 0.51 0.86 1.06 1.35 0.46 0.75 0.92 1.14 0.40 0.65 0.79 0.94 0.35 0.56 0.67 0.75 0.30 0.48 0.56 0.57 0.26 0.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Kilowatts) Evap Temp °C Evap Pres. Bar 10° C 3.13 bar 5° C 2.48 bar 0° C 1.92 bar -5° C 1.42 bar -10° C .993 bar -15° C .625 bar -20° C .3149 bar Pres Drop bar 0.07 0.2 0.35 0.7 0.07 0.2 0.35 0.7 0.07 0.2 0.35 0.7 0.07 0.2 0.35 0.7 0.07 0.2 0.35 0.7 0.07 0.2 0.35 0.7 0.07 0.2 0.35 0.7 03 3/8" 9 mm 2.05 3.38 4.31 5.54 1.85 3.02 3.82 4.82 1.65 2.68 3.36 4.13 1.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Tons) Evap Temp °F Evap Pres. psig 50° F 104.7 psig 40° F 86.4 psig 30° F 70.3 psig 20° F 56.2 psig 10° F 44.0 psig 0° F 33.5 psig -10° F 24.5 psig -20° F 16.8 psig -30° F 10.4 psig -40° F 5.0 psig Pres Drop psi 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 03 3/8" 9 mm 0.63 1.08 1.37 1.85 0.56 0.96 1.22 1.64 0.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Kilowatts) Evap Temp °C Evap Pres. Bar 10° C 8.1 bar 5° C 7.0 bar 0° C 6.0 bar -5° C 5.1 bar -10° C 4.3 bar -15° C 3.6 bar -20° C 3.0 bar -25° C 2.5 bar -30° C 2.0 bar -40° C 1.3 bar Pres Drop bar 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Tons) Evap Temp °F Evap Pres. psig 50° F 109 psig 40° F 89.8 psig 30° F 73.3 psig 20° F 58.8 psig 10° F 46.1 psig 0° F 35.2 psig -10° F 25.8 psig -20° F 17.8 psig -30° F 11.1 psig -40° F 5.5 psig Pres Drop psi 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 1 3 5 10 03 3/8" 9 mm 0.66 1.12 1.42 1.93 0.59 1.00 1.27 1.71 0.52 0.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Suction Capacities A8, (S)PORT and SC A8, (S)PORT & SC Suction Capacities (Kilowatts) Evap Temp °C Evap Pres. Bar 10° C 7.5 bar 5° C 6.3 bar 0° C 5.26 bar -5° C 4.3 bar -10° C 3.5 bar -15° C 2.8 bar -20° C 2.1 bar -25° C 1.6 bar -30° C 2.1 bar -40° C 0.38 bar Pres Drop bar 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.2 0.4 0.8 0.07 0.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information A8 Pressure Regulators A8 Pressure Regulators Features and Benefits • Dual range spring for flexibility in application. • Highest capacity commercial regulator in the industry. • Molded Class H coil construction. • Internally pilot operated. • Manual opening stem. • Interchangeable capacity cartridges. • Inlet, outlet, or differential control capability. • Sweat-in place without disassembly.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information A8 Pressure Regulators Installation: For those A8 regulators having an intregal pilot solenoid feature, the solenoid operators utilize a spring loaded solenoid plunger design, which assists the plunger in closing off tightly against the solenoid pilot seat regardless of position or orientation. The regulator can therefore be installed in either a horizontal or vertical pipe line regardless of valve variation.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information A9 Pressure Regulators A9 Pressure Regulators Standard Voltages • 120V/60Hz, 110V/50Hz • 240V/60Hz, 220V/50Hz • 208V/60Hz • 240V/60Hz, 220V/50Hz (DIN) • 240V/50Hz (DIN) Features and Benefits • Pilot operated for precise control of set point. • External or internal equalizer. • Available with integral electric shut-off. • Sweat-in place without disassembly. • Molded class H coil construction.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information CK4 Check Valve CK4 Check Valve Features and Benefits • Spring-loaded, in-line check valve. • Compact size, mounts in any position. • A minimum pressure difference of .75 psi (.05 bar) required to fully open valve. • Several ODS connection sizes available for most port size valves. • Positive spring closing action. • Lapped, metal to metal stainless steel or chrome plated seat. • Various flanged connections available.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities CK4 Check Valve CK4A Liquid Drain Capacities (Tons) Cond Temp Sat pres (psig) 75° F (132) Evap Temp -40° F 0° F 40° F 95° F (182) -40° F 0° F 40° F 115° F (243) -40° F 0° F 40° F Pres Drop psi 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 CK4A2 1/2" 13 mm 9.9 19.8 10.5 21.0 11.0 22.0 8.9 17.8 9.5 19.0 10.0 20.0 7.9 15.9 8.5 17.0 9.0 18.0 CK4A3 3/4" 20 mm 20.7 41.4 21.9 43.8 23.0 46.0 18.6 37.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities CK4 Check Valve CK4A Liquid Drain Capacities (Kilowatts) Cond Temp (Sat pres) bar 25° C (9.2) Evap Temp -40° C -20° C 0° C 30° C (10.9) -40° C -20° C 0° C 35° C (12.6) -40° C -20° C 0° C Pres Drop bar 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 CK4A2 1/2" 13 mm 33.7 69.0 35.5 72.8 37.2 76.2 32.2 65.9 34.0 69.6 35.6 73.0 30.6 62.8 32.4 66.5 34.1 69.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities CK4 Check Valve CK4A Liquid Drain Capacities (Tons) Cond Temp (Sat pres) psig 75° F (161.2) Evap Temp -40° F 0° F 40° F 95° F (219.4) -40° F 0° F 40° F 115° F (290.9) -40° F 0° F 40° F Pres Drop psi 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 0.75 3 CK4A2 1/2" 13 mm 6.6 13.2 7.4 14.8 8.1 16.3 5.5 11.0 6.3 12.5 7.0 13.9 4.3 8.6 5.0 10.1 5.7 11.5 CK4A3 3/4" 20 mm 13.8 27.6 15.5 31.0 17.0 34.0 11.5 22.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities CK4 Check Valve CK4A Liquid Drain Capacities (Kilowatts) Cond Temp (Sat pres) bar 25° C (11.2) Evap Temp -40° C -20° C 0° C 30° C (13.1) -40° C -20° C 0° C 35° C (15.1) -40° C -20° C 0° C Pres Drop bar 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 0.05 0.21 CK4A2 1/2" 13 mm 22.2 45.6 24.7 50.6 27.0 55.3 20.5 42.0 22.9 47.0 25.2 51.6 18.7 38.3 21.1 43.3 23.4 47.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information Condenser Pressure Control Condenser Pressure Control For Air Cooled Condensers Parker Refrigerating Specialties and Flo-Con regulators provide the wide range of adjustment of condenser and receiver pressures required for the most efficient operation of large air-cooled condenser systems.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information Condenser Pressure Control Figure 1 — Liquid drain method, condenser pressure control. (See page 346 for symbol legend.) Flo-Con Pressure Regulators & Valves Valve Legend Figure 2 — Discharge gas control method, condenser pressure control. (See page 346 for symbol legend.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities A8 Pressure Regulators A8 Liquid Drain Capacities (Tons) Cond Temp (Sat pres) psig 75° F (132) 95° F (182) 115° F (243) Evap Temp (Sat Pres) psig -40° F (0.5) 0° F (24.0) 40° F (68.5) -40° F (0.5) 0° F (24.0) 40° F (68.5) -40° F (0.5) 0° F (24.0) 40° F (68.5) Pres Drop psi 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 A8 3/8" 9 mm 8.7 12.4 9.3 13.1 9.7 13.7 7.9 11.1 8.4 11.9 8.8 12.5 7.0 9.9 7.5 10.6 7.9 11.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities A8 Pressure Regulators A8 Liquid Drain Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (9.2) 30° C (10.9) 35° C (12.6) Evap Temp (Sat Pres) bar -40° C (0.0) -20° C (1.4) 0° C (4.0) -40° C (0.0) -20° C (1.4) 0° C (4.0) -40° C (0.0) -20° C (1.4) 0° C (4.0) Pres Drop bar 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 A8 3/8" 9 mm 29.7 42.0 31.3 44.3 32.8 46.4 28.4 40.1 30.0 42.4 31.4 44.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities A8 Pressure Regulators A8 Liquid Drain Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (161.2) 95° F (219.4) 115° F (290.9) Evap Temp (Sat Pres) psig -40° F (2.7) 0° F (33.5) 40° F (86.4) -40° F (2.7) 0° F (33.5) 40° F (86.4) -40° F (2.7) 0° F (33.5) 40° F (86.4) Pres Drop psi 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 A8 3/8" 9 mm 5.8 8.3 6.5 9.2 7.2 10.2 4.8 6.9 5.5 7.8 6.2 8.7 3.8 5.4 4.5 6.3 5.1 7.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Liquid Drain Capacities A8 Pressure Regulators A8 Liquid Drain Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (11.2) 30° C (13.1) 35° C (15.1) Evap Temp (Sat Pres) bar -40° C (0.3) -20° C (2.0) 0° C (4.9) -40° C (0.3) -20° C (2.0) 0° C (4.9) -40° C (0.3) -20° C (2.0) 0° C (4.9) Pres Drop bar 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 A8 3/8" 9 mm 19.6 27.8 21.8 30.8 23.8 33.7 18.1 25.6 20.2 28.6 22.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (132) 75° F (132) 75° F (132) 95° F (182) 95° F (182) 95° F (182) 115° F (243) 115° F (243) 115° F (243) Evap Temp (Sat Pres) psig -40° F (0.5) 0° F (24.0) 40° F (68.5) -40° F (0.5) 0° F (24.0) 40° F (68.5) -40° F (0.5) 0° F (24.0) 40° F (68.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (9.2) 25° C (9.2) 25° C (9.2) 30° C (10.9) 30° C (10.9) 30° C (10.9) 35° C (12.6) 35° C (12.6) -20° C (1.4) 0° C (4.0) -40° C (0.0) -20° C (1.4) 0° C (4.0) -40° C (0.0) -20° C (1.4) 0° C (4.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (78.6) 75° F (78.6) 75° F (78.6) 95° F (113.8) 95° F (113.8) 95° F (113.8) 115° F (158.4) 115° F (158.4) 115° F (158.4) Evap Temp (Sat Pres) psig -40° F (14.7 in. hg) 0° F (6.5) 40° F (35.1) -40° F (14.7 in. hg) 0° F (6.5) 40° F (35.1) -40° F (14.7 in. hg) 0° F (6.5) 40° F (6.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (5.5) 25° C (5.5) 25° C (5.5) 30° C (6.7) 30° C (6.7) 30° C (6.7) 35° C (7.8) 35° C (7.8) -20° C (91.4 mm hg) 0° C (1.9) -40° C (373 mm hg) -20° C (91.4 mm hg) 0° C (1.9) -40° C (373 mm hg) -20° C (91.4 mm hg) 0° C (1.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (161.2) 75° F (161.2) 75° F (161.2) 95° F (219.4) 95° F (219.4) 95° F (219.4) 115° F (290.4) 115° F (290.4) 115° F (290.4) Evap Temp (Sat Pres) psig -40° F (2.7) 0° F (33.5) 40° F (86.4) -40° F (2.7) 0° F (33.5) 40° F (86.4) -40° F (2.7) 0° F (33.5) 40° F (86.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (11.2) 25° C (11.2) 25° C (11.2) 30° C (13.1) 30° C (13.1) 30° C (13.1) 35° C (15.1) 35° C (15.1) -20° C (2.0) 0° C (4.9) -40° C (0.3) -20° C (2.0) 0° C (4.9) -40° C (0.3) -20° C (2.0) 0° C (4.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (167.0) 75° F (167.0) 75° F (167.0) 95° F (226.0) 95° F (226.0) 95° F (226.0) 115° F (301.0) 115° F (301.0) 115° F (301.0) Evap Temp (Sat Pres) psig -40° F (5.5) 0° F (35.2) 40° F (89.8) -40° F (5.5) 0° F (35.2) 40° F (89.8) -40° F (5.5) 0° F (35.2) 40° F (89.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities A8 Pressure Regulators A8 Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (11.6) 25° C (11.6) 25° C (11.6) 30° C (13.5) 30° C (13.5) 30° C (13.5) 35° C (15.6) 35° C (15.6) -20° C (2.1) 0° C (5.2) -40° C (0.4) -20° C (2.1) 0° C (5.2) -40° C (0.4) -20° C (2.1) 0° C (5.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (132) 75° F (132) 75° F (132) 95° F (182) 95° F (182) 95° F (182) 115° F (243) 115° F (243) 115° F (243) Evap Temp (Sat Pres) psig -40° F (0.5) 0° F (24.0) 40° F (68.5) -40° F (0.5) 0° F (24.0) 40° F (68.5) -40° F (0.5) 0° F (24.0) 40° F (68.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (9.2) 25° C (9.2) 25° C (9.2) 30° C (10.9) 30° C (10.9) 30° C (10.9) 35° C (12.6) 35° C (12.6) -20° C (1.4) 0° C (4.0) -40° C (0.0) -20° C (1.4) 0° C (4.0) -40° C (0.0) -20° C (1.4) 0° C (4.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (78.6) 75° F (78.6) 75° F (78.6) 95° F (113.8) 95° F (113.8) 95° F (113.8) 115° F (158.4) 115° F (158.4) 115° F (158.4) Evap Temp (Sat Pres) psig -40° F (14.7 in hg) 0° F (6.5) 40° F (35.1) -40° F (14.7 in hg) 0° F (6.5) 40° F (35.1) -40° F (14.7 in hg) 0° F (6.5) 40° F (35.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (5.5) 25° C (5.5) 25° C (5.5) 30° C (6.7) 30° C (6.7) 30° C (6.7) 35° C (7.8) 35° C (7.8) -20° C (91.4 mm hg) 0° C (1.9) -40° C (373 mm hg) -20° C (91.4 mm hg) 0° C (1.9) -40° C (373 mm hg) -20° C (91.4 mm hg) 0° C (1.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (161.2) 75° F (161.2) 75° F (161.2) 95° F (219.4) 95° F (219.4) 95° F (219.4) 115° F (290.4) 115° F (290.4) 115° F (290.4) Evap Temp (Sat Pres) psig -40° F (2.7) 0° F (33.5) 40° F (86.4) -40° F (2.7) 0° F (33.5) 40° F (86.4) -40° F (2.7) 0° F (33.5) 40° F (86.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (11.2) 25° C (11.2) 25° C (11.2) 30° C (13.1) 30° C (13.1) 30° C (13.1) 35° C (15.1) 35° C (15.1) -20° C (2.0) 0° C (4.9) -40° C (0.3) -20° C (2.0) 0° C (4.9) -40° C (0.3) -20° C (2.0) 0° C (4.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Tons) Cond Temp (Sat Pres) psig 75° F (167) 75° F (167) 75° F (167) 95° F (226) 95° F (226) 95° F (226) 115° F (301) 115° F (301) 115° F (301) Evap Temp (Sat Pres) psig -40° F (5.5) 0° F (35.2) 40° F (87.8) -40° F (5.5) 0° F (35.2) 40° F (87.8) -40° F (5.5) 0° F (35.2) 40° F (89.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Discharge Capacities CK4A Check Valves CK4A Hot Gas Discharge Capacities (Kilowatts) Cond Temp (Sat Pres) bar 25° C (11.6) 25° C (11.6) 25° C (11.6) 30° C (13.5) 30° C (13.5) 30° C (13.5) 35° C (15.6) 35° C (15.6) -20° C (2.1) 0° C (5.2) -40° C (0.4) -20° C (2.1) 0° C (5.2) -40° C (0.4) -20° C (2.1) 0° C (5.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Tons) Cond Temp Ev. Temp (Sat pres) (Sat Pres) Discharge psig psig Temp °F 75° F -40° F 140° (132) (5.5) 180° 220° 140° 180° 220° 75° F 0° F 140° (132) (35.2) 180° 220° 140° 180° 220° 75° F 40° F 140° (132) (87.8) 180° 220° 140° 180° 220° 95° F -40° F 140° (182) (5.5) 180° 220° 140° 180° 220° 95° F 0° F 140° (182) (35.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Kilowatts) Pres Drop psi 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 A9 3/8" 9 mm 12.9 13.1 13.4 15.5 15.8 16.1 13.6 13.8 14.1 16.4 16.7 17.0 14.2 14.5 14.8 17.2 17.5 17.8 11.6 11.8 12.1 14.0 14.2 14.5 12.3 12.5 12.8 14.8 15.1 15.3 12.9 13.1 13.4 15.5 15.8 16.1 10.6 10.8 11.0 12.7 13.0 13.2 11.2 11.4 11.7 13.5 13.7 14.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Tons) Cond Temp Ev. Temp (Sat pres) (Sat Pres) Discharge psig psig Temp °F 75° F -40° F 140° (78.6) (5.5) 180° 220° 140° 180° 220° 75° F 0° F 140° (78.6) (35.2) 180° 220° 140° 180° 220° 75° F 40° F 140° (78.6) (87.8) 180° 220° 140° 180° 220° 95° F -40° F 140° (113.8) (5.5) 180° 220° 140° 180° 220° 95° F 0° F 140° (113.8) (35.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Kilowatts) Pres Drop psi 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 A9 3/8" 9 mm 8.9 9.2 9.5 10.7 11.1 11.5 9.6 10.0 10.3 11.6 12.1 12.5 10.4 10.8 11.1 12.5 13.0 13.4 8.0 8.2 8.5 9.6 9.9 10.3 8.7 9.0 9.3 10.5 10.8 11.2 9.4 9.7 10.1 11.3 11.7 12.1 7.2 7.5 7.7 8.7 9.0 9.3 7.9 8.2 8.5 9.5 9.8 10.2 8.6 8.9 9.2 10.3 10.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Tons) Cond Temp Ev. Temp (Sat pres) (Sat Pres) Discharge psig psig Temp °F 75° F -40° F 140° (161.2) (5.5) 180° 220° 140° 180° 220° 75° F 0° F 140° (161.2) (35.2) 180° 220° 140° 180° 220° 75° F 40° F 140° (161.2) (87.8) 180° 220° 140° 180° 220° 95° F -40° F 140° (219.4) (5.5) 180° 220° 140° 180° 220° 95° F 0° F 140° (219.4) (35.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Kilowatts) Pres Drop psi 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 A9 3/8" 9 mm 8.0 8.3 8.6 9.7 10.1 10.5 8.9 9.2 9.6 10.8 11.2 11.6 9.8 10.1 10.5 11.8 12.3 12.7 6.9 7.2 7.4 8.4 8.7 9.0 7.8 8.0 8.3 9.4 9.7 10.1 8.5 8.9 9.2 10.3 10.7 11.1 6.0 6.2 6.4 7.2 7.5 7.8 6.8 7.0 7.3 8.2 8.5 8.8 7.5 7.8 8.1 9.1 9.4 9.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Tons) Cond Temp Ev. Temp (Sat pres) (Sat Pres) Discharge psig psig Temp °F 75° F -40° F 140° (167) (5.5) 180° 220° 140° 180° 220° 75° F 0° F 140° (167) (35.2) 180° 220° 140° 180° 220° 75° F 40° F 140° (167) (87.8) 180° 220° 140° 180° 220° 95° F -40° F 140° (226) (5.5) 180° 220° 140° 180° 220° 95° F 0° F 140° (226) (35.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Condensor Bypass Capacities A8 and A9 Pressure Regulators A9 and A8_0 Condenser Bypass Capacities (Kilowatts) Pres Drop psi 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 0.7 1 A9 3/8" 9 mm 8.3 8.7 9.1 10.1 10.5 10.9 9.2 9.6 10.0 11.2 11.6 12.1 10.1 10.5 10.9 12.2 12.7 13.2 7.3 7.6 8.0 8.9 9.2 9.6 8.2 8.5 8.9 9.9 10.3 10.7 9.0 9.4 9.7 10.8 11.3 11.7 6.5 6.8 7.0 7.8 8.1 8.5 7.3 7.6 7.9 8.8 9.1 9.5 8.1 8.4 8.7 9.7 10.1 10.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information Hot Gas Bypass Hot Gas Bypass Hot gas bypass is a method of compressor capacity control that has been utilized in the refrigeration and air conditioning industry for many years. A significant number of refrigeration and air conditioning systems operate at full capacity no more than 20% of their running time.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information Hot Gas Bypass Figure 3 - Hot gas bypass to entrance of evaporator. (See page 346 for symbols legend). Figure 4 - Hot gas bypass to suction with liquid injection. (See page 346 for symbols legend).
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Hot Gas Bypass Capacities Flo-Con Pressure Regulators and Valves Hot Gas Bypass Capacities (Tons) Cond. Temp. 86° F 100° F 110° F 120° F Discharge Temp 140° F 180° F 220° F 140° F 180° F 220° F 140° F 180° F 220° F 140° F 180° F 220° F A9 3/8 1.4 1.5 1.5 1.6 1.7 1.8 1.8 1.9 1.9 1.9 2.0 2.1 A9 5/8 4.1 4.3 4.5 4.8 5.0 5.2 5.2 5.5 5.7 5.7 6.0 6.3 A9 7/8 12.0 12.4 12.9 13.8 14.4 15.0 15.1 15.9 16.6 16.4 17.3 18.2 A9 1-1/8 19.1 19.9 20.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Hot Gas Bypass Capacities Flo-Con Pressure Regulators and Valves Hot Gas Bypass Capacities (Kilowatts) Cond. Temp. 30° C 40° C 45° C 50° C Discharge Temp 60° C 80° C 100° C 60° C 80° C 100° C 60° C 80° C 100° C 60° C 80° C 100° C A9 9 mm 4.9 5.1 5.3 5.9 6.1 6.4 6.4 6.7 7.0 6.8 7.2 7.5 A9 15 mm 14.6 15.1 15.6 17.4 18.2 18.9 18.8 19.7 20.6 20.2 21.3 22.3 A9 22 mm 42.1 43.6 45.1 50.3 52.5 54.6 54.5 57.0 59.5 58.4 61.5 64.5 A9 28 mm 67.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information Discharge Regulators Discharge Regulators for Supermarket Applications The Parker Refrigerating Specialties Division has built a reputation as a principal supplier of reliable, high side control valves to the supermarket industry. One of the more critical applications on a commercial refrigeration system where hot gas is utilized for defrosting purposes is the use of a regulator in the discharge line.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information Crankcase Pressure Regulators Crankcase Pressure Regulators Crankcase pressure regulators, also known as “CPRs” or “holdback” regulators, are outlet pressure regulators installed in the suction line which prevent an excessive downstream pressure regardless of fluctuations in load or inlet conditions.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information SC Suction Solenoid Valves SC Suction Solenoid Valves Key Features and Benefits • Highest capacity non-flanged valve in the industry. • Available with 208V/240V/60Hz wide range voltage coil. • Low pressure drop, internally pilot operated. • All stainless steel bolts, stem, piston and plug. • Manual opening stem. • Sweat in place without disassembly. • Molded class “F” coil construction. • DIN coil assemblies available.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information SC Suction Solenoid Valves for reassembly. The internal cartridge-to-body O-ring will need to be replaced prior to reassembly. common commercial refrigerants along with certain oils. The SC solenoid may be opened by means of a manual opening stem for servicing or in case of an electrical power failure.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information S81/S82 Solenoid Valves S81/S82 Solenoid Valves Features • Highest capacity non-flanged solenoid valve in the industry. • Low pressure drop. • Manual opening stem. • Sweat in place without disassembly. • Molded class “H” coil construction. • DIN coil assemblies available. • Inlet pressure access fitting. • Interchangeable capacity cartridges. Specifications • Maximum opening pressure differential (MOPD): 300 psig (20.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Technical Information S81/S82 Solenoid Valves Description: The S8 series of commercial solenoids was developed as a versatile, general purpose, commercial refrigeration valve, capable of being applied in most liquid, hot gas, or suction applications. With cartridge (port) sizes available up to 2-5/8" (66mm) in size, S8 solenoids offer the greatest capacity of any non-flanged commercial solenoid in the industry.
Flo-Con Pressure Regulators and Valves Catalog CIC-2003-1/US Abbreviations and Terminology Abbreviations and Terminology Abbreviations A (Amp) Ampere BTU/hr British Thermal Units per Hour BTU/min. British Thermal Units per Minute °C Degrees Celsius or Centigrade cm2 (sq.
Industrial Refrigeration Products Catalog CIC-2003-1/US Table of Contents Industrial Refrigeration Products Pressure Regulators .........................................................................................................................................................................349 A2A/A2B Small Capacity Regulators ............................................................................................ 350 A2CK Reseating Relief Regulators ...........................................
Catalog CIC-2003-1/US Industrial Refrigeration Products General Information Industrial Refrigeration Products How to Use this Section This section is organized by product group. For most sections, the first page is an overview. Specifications and selection guides given in table form provide comparison of the different valves and aid in selecting a specific product.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Overview Pressure Regulators Pressure Regulators The Refrigerating Specialties family of pressure regulators includes valves that control inlet, outlet or differential pressure. Each regulator is available with an assortment of additional variations which enable one regulator to perform several functions. A2 The Type A2 are compact, small capacity regulators.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Type A2 Compact Regulators Technical Information ● ● ● ● ● Compact, direct diaphragm operated Maximum rated pressure (MRP): 27.6 bar (400 PSIG) Flanged connections: FPT, SW, WN, ODS Available with close coupled strainer Stainless steel diaphragm Description The A2 type pressure regulators are compact, direct diaphragm operated, for use with refrigerant liquid or vapor.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Type A2 Compact Regulators Dimensions and How to Order 117mm (4.6") Dimensions A2A, A2B A2*T 177mm (7") 173mm (6.8") 211mm (8.3") 241mm (9.5") DIAPHRAGM PUSH PIN THERMAL ELEMENT CAPILLARY LENGTH = 6m (20 FT) 73mm (2.9") 117mm (4.6") 19mm (0.75") 73mm (2.9") 102mm (4") How to Order Type A2 Regulators Regulators can be specified by using the symbols in the chart below to develop a model number.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Type A2CK Relief Regulators Technical Information ● ● ● ● Compact, direct diaphragm operated Maximum rated pressure (MRP): 27.6 bar (400 PSIG) Flanged connections: FPT, SW, WN, ODS Available with close coupled strainer Description The A2CK pressure relief regulator is direct diaphragm operated, for use with refrigerant liquid or vapor. The regulators can be used with ammonia, R-22, R-134a, R-507 and other common refrigerants.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Type A2CK Compact Relief Regulators How to Order How to Order A2CK Compact Relief Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information ● Pilot operated for precise control ● Characterized modulating plug for stable control under low flow conditions ● Many control variations are possible ● Convertible to other variations ● Optional close coupled strainers up to 100mm (4") ● Manual opening stem ● Easy to service Flanged Body Style 20-100mm Ports Description These compact, heavy-duty, pilot-operated regula
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Application Guide There are many possible combinations of A4 regulator variations. The electric shut-off (S), electric wide-opening (B) and dual pressure (D) variations are often combined with each other. Or they may be used in combination with the compensated (M, P, 3P and T), outlet pressure (O) or differential pressure (L) regulators.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information A4 Basic Inlet A4Z Inlet with Modudapter® A4B Electric Wide Opening A4JS Electronic Pilot Operated A4O Basic Outlet A4K Relief A4S Electric Shut-Off A4M Electrically Compensated 356 A4L Differential Pressure A4P Pressure Compensated A4D Dual Pressure A4OT Temperature Operated Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Regulator Variations Ordering Information Required Added Variation Code Catalog Pages* Pressure Range(s) Voltage, Coil Pilot Light Motor Set Point Temp.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Basic Inlet Regulators, 20-100mm (¾" - 4") A4 inlet regulators open on a rise in inlet pressure above the set point and close on a drop in inlet pressure below the set point. The inlet pressure set point is not appreciably affected by variations in outlet pressure.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Basic Inlet Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Basic Outlet Regulators, 20-100mm (¾" - 4") Outlet regulators modulate flow of refrigerant gas or liquid to maintain a constant downstream pressure as set-for, despite fluctuations in load. The regulator will gradually close when downstream pressure begins to rise above the setting and will gradually open when pressure begins to fall below the setting.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Outlet Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Differential & Pressure Compensated, 20-100mm (¾" - 4") regulator set-point will be directly varied on a 1:1 basis with value of the air pressure supplied to the bonnet. A 3:1 setpoint variation is also available for inlet pressure regulators (A3P). Generally the pneumatic controller modulates the air pressure from 3 to 15 PSIG throughout its control range.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Differential & Pressure Compensated Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Temperature Operated Regulators (20-100mm) The temperature compensated pressure regulator differs from the conventional pressure regulator in that rather than maintaining a previously set constant pressure, this regulator modulates pressure in accordance with the demands of the load. The regulator will vary its pressure set point as load demand varies as sensed by the thermal bulb.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Temperature Operated Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Electrically Compensated Regulators, 20-100mm (¾" - 4") Type A4M electrically compensated inlet pressure regulators modulate the flow of refrigerant gas or liquid to maintain a varying upstream (Inlet) pressure in response to an electrical signal applied to a low-voltage motor mounted on a regulator pilot. A4OM regulators modulate outlet pressure.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Electrically Compensated Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart. Port Size Type 020 A4 OMS1 Variation Low Gauge Press.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Electronic Pilot Operated Regulators, 20-100mm (¾" - 4") Type A4J electronic pilot operated regulators utilize a Landis & Staefa M2FP03GX direct operated proportional solenoid as a pilot valve to modulate the flow of pilot pressure to the top of the regulator's piston.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Electronic Pilot Operated Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart. Port Size Type Variation Range 020 A4 J1 A Low Gauge Press.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series Technical Information Weld End Regulators, 125-200mm (5" - 8") These heavy duty, cast steel bodied pressure regulators weld directly in the line and do not require flanges. As with the flanged body regulators, they are pilot operated and use the same modules to configure many variations. These valves can be ordered with the R/S strainer to be welded directly to the inlet of any regulator.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Series How to Order How to Order Weld End Regulators Regulators can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Modules Technical Information A2D Modular Pressure Pilot Adds dual (D) variation when combined with Modular Solenoid Pilot (below). Provides a second higher control pressure. Type Range A2D A Type A2D2 Furnished with bolts and O-rings. A2D Mounts to Modudapter® . Same for all regulator sizes. Range Use with 20-50mm (¾" to 2") Size A4 Use with 65-200mm (2½" to 8") Size A4 A 0-10.3 Bar (0-150 PSIG) 5.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Modules Technical Information Modudapter® (MD, SMD) The special adapter to which the modular solenoid pilot, modular pressure pilot and Moduplate are bolted. The Series Modudapter (SMD) is used with special regulators such as A4DS, A4BDS, etc. Furnished with bolts and gaskets. (Standard part of regulators with S, B, D and Z variations) NOTE: Use SMD65 for all 125-200mm (5" - 8") A4 regulators.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators A4 Adaptomode® Modules Technical Information Pressure Bonnet Kit (PK) Converts any A4, A4O or A2 Series regulator to 1:1 Pressure Compensation (P) variation . Standard in A range. Use with Type VC vacuum cartridge for V range. Type Also available 3:1 pressure compensation (3P) variation.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Regulator Accessories Technical Information Electric Proportioning Thermostat (T27) Use with “M” variation regulators. Specifications: Range ......... -34° to 21° C (-30° to 70° F) Capillary ................... 1.5m (5') standard Bulb ............ 12.7mm dia. x 106mm long (½" dia. x 43⁄16" long) Sensitivity adjustable ...... 1.7° to 16.
Catalog CIC-2003-1/US Industrial Refrigeration Products: Pressure Regulators Solenoid Coils Technical Information maximum coil temperature is not exceeded. Conversely, low fluid temperatures permit higher ambient temperatures. Class “ B” Coil (S6A) The molded water resistant Class “B” solenoid coil, available on most Refrigerating Specialties solenoid valves, is designed for long life and powerful opening force. The standard coil housing meets NEMA 3R and 4 requirements.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Overview Solenoid Valves Solenoid Valves The Refrigerating Specialties family of solenoid valves includes direct operated and pilot operated valves. Selections for most refrigeration applications are available – liquid, suction, hot gas and compressor unloading. Low or no pressure differential, equalizing and vent solenoid in sizes up to 50mm (2").
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information Type S6N ● Coil Housing Surpasses NEMA Salt Spray Test ● Accepts Either Open Frame or Totally Encapsulated Coils ● Direct Acting, Normally Closed Operation ● Replaceable Teflon Seat ● Manual Opening Stem ● Stainless Steel Needle ● Pilot Light Available ● Maximum Opening Pressure Difference (MOPD) is 20.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type S6N How to Order Type S6N solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● Type S8F Coil Housing Surpasses NEMA Salt Spray Test Accepts Either Open Frame or Totally Encapsulated Coils Replaceable Piston Plug Assembly Stainless Steel Needle Pilot Light Available Manual Opening Stem Maximum Opening Pressure Difference (MOPD) is 20.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type S8F How to Order Type S8F solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● Type SV2 Pilot Operated Molded Class “H” Coil Construction Pilot Light Available Manual Opening Stem MOPD 20.7 bar (300 PSIG); MRP 31.0 bar (450 PSIG) All Service from the Top Description This compact, heavy duty, pilot-operated solenoid valve is suitable for ammonia and other common refrigerants, certain oils and other fluids approved for use in refrigeration.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type SV2 How to Order Type SV2 solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● ● ● Type S7 Positive Lift, Held Open Electrically Standard Coil Housing Meets NEMA 3R and NEMA 4 – Rain Tight Coil Housing Surpasses NEMA Salt Spray Test Gray Iron Body, PTFE Seat Molded Class “B” Coil Construction Pilot Light Available Stainless Steel Needle Manual Opening Stem MRP 27.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type S7 How to Order Type S7 solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● ● Type S5 Standard Coil Housing Meets NEMA 3R and NEMA 4 – Rain Tight Coil Housing Surpasses NEMA Salt Spray Test Replaceable Piston Plug Assembly Molded Class “B” Coil Construction Pilot Light Available Stainless Steel Needle Manual Opening Stem MOPD is 20.7 bar (300 PSIG); MRP is 27.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type S5 How to Order Type S5 solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● Type S4 (20-100mm) Standard Coil Housing Meets NEMA 3R and NEMA 4 – Rain Tight Coil Housing Surpasses NEMA Salt Spray Test Molded Class “B” Coil Construction Pilot Light Available Stainless Steel Needle Manual Opening Stem MOPD is 20.7 bar (300 PSIG); MRP is 27.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type S4 (20-100mm) How to Order Type S4 solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● ● ● Type S4 (125-200mm) Pilot Operated Welds directly in the Line – No Flanges Removable Seat is Serviceable from Top Side Streamlined Fluid Flow Pattern Cast Steel Body, ASTM No. A352 Grade LCB PTFE Pilot Seat Molded Class “B” Coil Construction Manual Opening Stem MOPD 20.7 bar (300 PSIG); MRP 27.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US How to Order Type S4 (125-200mm) How to Order Type S4 solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information and How to Order ● ● ● Remote Pilot Light Assembly Pilot Light Assembly is Completely Self-Contained Gives Visual Observation of Solenoid Valve Operation Standard Conduit Box or Weatherproof Design PLT-1 Description The PLT-1 assembly is completely self-contained, consisting of a standard conduit box with multiple knockouts for connecting to the R/S coil housing cover.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information External Pilot Light Assembly PLT-1 LENS 6-VOLT BULB NUT & LOCKWASHER ESCUTCHEON RING CONDUIT BOX SOLENOID COIL HOUSING PILOT LIGHT BASE CONNECT 6 VOLT LEADS FROM SOLENOID COIL TO TERMINALS OF PILOT LIGHT. CONDUIT BOX COVER CONDUIT NIPPLE 1/2" CONDUIT LOCK NUT 1/2" PLT-2 CONDUIT BOX O-RING SEALS O-RING SEALS COVER LIGHT 95mm (3.750") LOCKWASHER 1/2-14 NPT BOTH SIDES NUT VIEW A ENLARGED 98.
Industrial Refrigeration Products: Solenoid Valves Catalog CIC-2003-1/US Technical Information Electrical Coil Information The supply circuits must be properly sized to give adequate voltage at the coil even when other electrical equipment is operating. The coil is designed to operate with line voltage from 85% to 110% of rated coil voltage. Power consumption during normal operation will be 33 watts or less.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US Gas Powered Suction Stop Valves Overview ● ● ● ● ● ● ● ● Very low pressure drop for low temperatures Ideal for overfeed or flooded systems Use in Vertical or Horizontal Line Pilot Connection Contains Disc Strainer between a Pair of Flanges Suitable to -50° C (-60° F) Main valve can lie on its side for minimum pressure drop with two-phase flow Manual opening stem Condenser gas powered piston and heavy return spring o
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● ● ● Type CK2 Normally Open Low Pressure Drop Heavy Return Spring Manual Opening Stem Use in Vertical or Horizontal Line Main Valve Can be Installed on Side Maximum Rated Pressure (MRP): 27.6 bar (400 psig) Description These piston type, pressure powered, normally open, heavy duty valves are built with control valve precision.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US How to Order Type CK2 How to Order Type CK2 solenoid valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● ● ● Type CK5 Normally Open Low Pressure Drop Manual Opening Stem Integrated Pilot Solenoid on 32mm to 100mm (1 -1/4" to 4") Sizes Use in Vertical or Horizontal Line Can be Installed on Side Maximum Rated Pressure (MRP): 27.6 bar (400 psig) Description These piston-type, discharge gas powered, normally open, heavy duty valves are built with control precision.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US How to Order Type CK5 How to Order Type CK5 valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● ● Type S9 Flanged Body Port Sizes 50-100mm (2" - 4") Low Pressure Drop for Low Temperature Operation Suitable to -50° C (-60° F) Can Be Installed in Vertical or Horizontal Position Manual Opening Feature Maximum Rated Pressure (MRP): 27.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US How to Order Type S9 Flanged Body How to Order Type S9 flanged body valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● ● ● ● ● ● ● Type S9 Weld End Body Port Sizes 125-200mm (5" - 8") Pilot Operated Welds directly in the Line – No Flanges Removable Seat is Serviceable from Top Side Coil Size Same as Most Other R/S Valves Streamlined Fluid Flow Pattern Cast Steel Body, ASTM No.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US How to Order Type S9 Weld End Body How to Order Type S9 weld end body valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Gas Powered Suction Stop Valves Catalog CIC-2003-1/US Technical Information and How to Order S9 Pilot Assembly Description The S9 Pilot Assembly can be ordered separately from the valve for stock or field assembly. Assembly includes a S6N pressure pilot solenoid with close coupled strainer, a S6N bleed pilot solenoid, required piping and flange connections. See Note below. The 50mm (2") S9 valve uses a 050 size assembly.
Industrial Refrigeration Products: Check Valves Catalog CIC-2003-1/US Overview Check Valves CK1 CK3 CK4 CK4 13-100mm (½" - 4") 125-200mm (5" - 8") Specifications Type Port Size CK4A CK4A CK4A CK1 CK1 mm 13 20-100 125-200 20-32 40-150 inch ½" ¾" - 4" 5" - 8" ¾"- 1¼" 15/8" - 6" Stainless Steel Steel 34.5 500 -55° to 105° -60° to 220° Yes Yes 0.05 0.75 50-16 Stainless Steel Ductile Iron 34.5 500 -55° to 105° -60° to 220° Yes Yes 0.05 0.75 50-16 Stainless Steel Ductile Iron 34.
Industrial Refrigeration Products: Check Valves Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● Type CK4 UL Listed (Thru 3" Size) Installs in any position Compact and lightweight In-Line flanged valves Design Pressure (MRP): 34.5 bar (500 psi) Description 13-100mm (1/2" - 4") These compact valves are spring closing with a lapped, stainless steel or chrome plated seat for positive closing action and low leakage. A minimum pressure difference of 0.05 bar (0.
Industrial Refrigeration Products: Check Valves Catalog CIC-2003-1/US Dimensions and How to Order Type CK4 Dimensions Valve Length Valve Diameter Flange Outside Diameter Diameter of Bolt Circle Nominal Pipe Size Inches mm Inches mm Inches mm 125 mm (5") 4.125 104.8 8.375 212.7 11 279 9.25 235 8 150 mm (6") 200 mm (8") 4.625 5.625 117.5 142.9 9.750 12.000 247.7 304.8 12.5 15 318 381 10.62 13.
Industrial Refrigeration Products: Check Valves Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● ● Type CK1 Rugged, Heavy Duty Low Pressure Drop Piston Type Gravity Closing Flanged, horizontal mounting Design Pressure(MRP): 27.6 bar (400 psig) Manual Opening Stem Description These piston type, gravity closing, heavy duty check valves are suitable for Ammonia, R-22, R-134a, R-404A, R-507, other refrigerants, certain oils and other fluids approved for use in refrigeration.
Industrial Refrigeration Products: Check Valves Catalog CIC-2003-1/US How to Order Type CK1 How to Order Type CK1 check valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart. Port Size Type Inlet Flange Outlet Flange 050 CK1 F12 F12 Strainer S Not all flange sizes are available for each port size.
Industrial Refrigeration Products: Check Valves Catalog CIC-2003-1/US Technical Information, Dimensions and How to Order ● ● ● ● ● ● Type CK3 Small, Compact, Heavy Duty Heavy Spring Closing Installs in any position PTFE Seat Threaded Ends Maximum Rated Pressure (MRP): 27.6 bar (400 psig) Description: This compact, heavy duty, threaded in-line check valve is suitable for Ammonia, R-22, R-134a, R-404A, R-507 and other refrigerants, certain oils and other fluids approved for use in refrigeration.
Industrial Refrigeration Products: Safety Relief Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● Type H, M For use with R-22, R-717 and other common refrigerants High Capacity Excellent Repeatability Unaffected by Vibration Drain Plug Standard Description The Type H High Capacity Safety Relief Valves are designed and constructed to meet the requirements of ASME Boiler and Pressure Vessel Code and ANSI/ASHRAE 15-78 Code requirements and bear the ASME Code Symbol (UV) indicating compliance w
Industrial Refrigeration Products: Safety Relief Valves Catalog CIC-2003-1/US Dimensions Type H, M Dimensions C E N M D H OUTLET J OUTLET A K B INLET L INLET Single Valve Dimension H2 G Manifold with Two Valves H3 F H4 H5 mm inch mm inch mm inch mm inch A 251 9.87 295 11.62 340 13.37 371 14.62 B C 152 171 6.00 6.75 187 219 7.37 8.62 211 273 8.31 10.75 224 318 8.81 12.50 D 137 5.37 127 5.00 117 4.62 111 4.37 E 102 4.00 127 5.00 165 6.
Industrial Refrigeration Products: Safety Relief Valves Catalog CIC-2003-1/US Technical Information and How to Order Type H, M Specifications Note: Pressure settings and capacities apply only when the valve is discharging to atmospheric pressure.
Industrial Refrigeration Products: Safety Relief Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● Type SR/SRH SR Series designed to meet ASHRAE 15 2001 requirements for new system installations SRH Series designed to meet ASHRAE 15 1994 (or earlier) system requirements Certified by the National Board of Boilers and Pressure Vessel Inspectors All stainless steel internal parts PTFE seat Accurate and dependable Pressure relief settings from 10.3 - 27.
Industrial Refrigeration Products: Hand Valves Catalog CIC-2003-1/US Overview ● ● ● ● ● ● Hand Valves Suitable for fluorocarbon refrigerants (R-22, R-134a, R-404A, R-507 and others), ammonia (R-717), nitrogen and carbon dioxide.
Industrial Refrigeration Products: Hand Valves Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● ● ● Hand Valves ASTM 352 LCB Cast Steel Body (1/4" thru 12") Stainless Steel Stem Optional Stainless Steel Trim Reliable Back Seating Bolted Bonnets (1/4" thru 12") 25% Carbon Filled PTFE Seat Material Linear Flow “Y” Pattern Globe Body (1-1/4" thru 12") for Low Pressure Drop Extended Bonnets for Thicker Insulation Handwheel and Seal Cap Interchangeable on Same Valve Description This complete line o
Industrial Refrigeration Products: Hand Valves Catalog CIC-2003-1/US How to Order Hand Valves How to Order Hand valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Hand Valves Catalog CIC-2003-1/US Dimensions Hand Valves Threaded Connection (FPT), Standard Bonnet D H H1 H1 H L L1 L Angle Globe "T" Angle Globe Valve Size L L1 H H1 D L H H1 D 1/4", 3/8", 1/2" 3/4", 1" 1¼", 1½" 1.75 1.50 1.63 1.75 2.00 2.50 4.50 5.75 8.00 6.00 6.50 8.50 2.50 4.00 5.40 3.75 3.88 5.00 5.75 5.75 8.00 6.88 6.50 8.50 2.50 4.00 5.
Industrial Refrigeration Products: Hand Valves Catalog CIC-2003-1/US Dimensions Hand Valves Socket Weld Connection, Standard Bonnet D D H H1 H1 H H1 H L L1 L Angle L Globe "T" Valve Size L L1 Angle H H1 D L 1/4", 3/8", 1/2" ¾", 1" 1¼" 1½" 2" 2½" 3" 4" 1.75 1.50 2.75 2.75 3.12 3.75 3.88 4.50 4.75 2.00 2.75 2.75 3.12 3.75 3.88 4.50 4.50 5.75 7.88 7.88 8.38 9.00 10.75 11.63 6.00 6.50 8.25 8.25 8.63 9.25 11.38 12.00 2.50 4.00 5.40 5.40 5.40 5.40 6.70 6.75 3.75 3.88 7.00 8.25 8.25 9.
Industrial Refrigeration Products: Hand Valves Catalog CIC-2003-1/US Dimensions Hand Valves Butt Weld Connection, Standard Bonnet D D H H1 H1 H H1 H L L1 L Angle Valve Size L L1 Angle H H1 D 1¼" 1½" 2" 2½" 3" 4" 5" 6" 8" 10" 12" 2.75 2.63 3.00 3.63 3.63 4.62 6.00 6.38 7.88 9.75 10.50 2.75 2.63 3.00 3.88 3.88 5.00 6.00 6.38 7.88 9.75 10.50 7.75 8.12 8.50 11.12 11.12 11.38 13.00 14.50 17.00 25.75 25.50 8.25 9.12 8.75 11.75 11.75 12.00 15.00 15.50 18.00 27.25 28.75 5.40 5.40 5.40 6.75 6.
Industrial Refrigeration Products: Liquid Flow Regulators Catalog CIC-2003-1/US Technical Information, Dimensions and How to Order ● ● ● ● ● Type AFR (Adjustable Flow) External Adjustment Easy Setting Scale Eliminates System Balancing Integral Check Valve “Frost Free” Neck Description This precision built, heavy duty, self-contained, iron bodied Automatic Flow Regulator is used as a liquid control device for Ammonia Overfeed Systems.
Industrial Refrigeration Products: Liquid Flow Regulators Catalog CIC-2003-1/US Technical Information and How to Order ● ● ● Type FFR (Fixed Flow) Eliminates System Balancing Overcomes Flow Fluctuations Permits evaporator optimization Description The Fixed Flow Regulator is used as a liquid flow control device for Liquid Recirculation Systems and is suitable for use with R-22 and Ammonia.
Industrial Refrigeration Products: Liquid Flow Regulators Catalog CIC-2003-1/US Dimensions Type FFR Dimensions 76mm (3") Optional Strainer 152mm (6") 86mm (3.375") 178mm (7")* 1/2" or 3/4" FPT * For FFR-2 without strainer, deduct 51mm (2").
Industrial Refrigeration Products: Liquid Flow Regulators Catalog CIC-2003-1/US Notes 424 Parker Hannifin Corporation Climate & Industrial Controls Group Cleveland, OH
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Technical Information, Dimensions and How to Order ● ● ● ● ● ● ● ● ● Programmable Liquid Level Controller Oversized keypad on front panel for programming Easy to read enlarged LED digital display 5 programmable 6 amp fused relays Level simulation mode facilitates control wiring check and test Large enclosure with separable terminal blocks accommodate up to 14 gage wire Plug-in style terminal blocks with recessed screws Convent
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Technical Information and Dimensions ● ● ● ● ● ● ● ● ● Depth Tracker Transducer Probes Probe lengths: 2, 3, 4, 5, 6, 7, 8, 10 & 12 feet Integrated construction achieved by molding the PTFE sleeve directly to the center rod Electrical connection via 3/4” conduit boss or jacketed communications cable of suitable temperature/moisture protection Fully potted circuit board Local or remote digital read-out options Optional display
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Technical Information and How to Order Depth Tracker Transducer Probes Options Display Remote Display 4-20mA Return Signal 12-36 Volts Input Voltage No Display Liquid Crystal Display LCD Span Adjustment Probe Zero Adjustment LCD Zero Adjustment Local Display Probe Span Adjustment Zero LED Span LED Display Riser Optional Probelok Hex Boss Probelok Probelok Refer to Bulletin 61-30 for details on installation and
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● ● ● ● Refrigerant Float Switch Hermetically Sealed, Fused Switch Assembly Transparent Switch Housing for Visual Observation Magnetically Actuated, Mechanically Operated Single Stage, Single Pole, Double Throw Switch Float Controlled Rugged Construction Switch Assembly Fully Rotatable to Suit Installation Large Available Differential Minimizes Short Cycling or Actuation of Switch by Liquid Su
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Dimensions and How to Order Refrigerant Float Switch Dimensions Allow 229mm (9.0") for switch removal Optional Metal Cover 13mm (0.5") 544mm (21.4") 146mm (5.7") 206mm (8.1") 114mm (4.5") How to Order Refrigerant Float Switches can be specified by using the symbols in the chart below to develop a model number.
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Technical Information and How to Order ● ● ● ● ● Rapid Purger High Capacity 4 to 32 purge points Stainless steel insulated enclosure (32" L x 20" H x 8" D) 316 – L stainless steel shell and tube heat exchanger. All stainless steel interior flange and pipe connections. Description Rapid Purgers remove incondensibles from refrigeration systems.
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Dimensions Rapid Purger Dimensions Pressure Regulator Pressure Switch Hand Valve Liquid Line S6N Solenoid Valve Temperature Controller Ammonia Gauge 864mm (34") Check Valve w/Disc Strainer 508mm (20") Water Bubbler Vapor Vent Float Hand Valve Purge Gas Line Pressure Check Valve Heat Exchanger Liquid Drainer 813mm (32") 940mm (37") Notes: Purger styles that could encounter standby or power failure conditions suc
Industrial Refrigeration Products: Liquid Level Control Catalog CIC-2003-1/US Technical Information, Dimensions and How to Order ● ● ● ● ● ● ● ● Automatic Liquid Drainer (ALD) Drains Liquid Only Stops Flow of Vapor Prevents Vapor Lockup Built-in Strainer No Small Orifices Resists Wire Drawing Includes Pilot Light Manual Opening Stem Description Used to drain liquid from defrosting evaporators or heat recovery condensors into a lower pressure portion of the system.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information and Dimensions Flanges Flange Types Flanges are sold individually and are available in male tongue type to fit sizes 5-150mm (1/2" to 6") and female groove type to fit sizes 5-100mm (1/2" to 4"). The following connection styles are available: ● ● ● ● ● ● ● Female Pipe Thread (FPT) Socket Weld (SW) Weld Neck (WN). Metric WN flanges also available in connection sizes ranging from 15 to 100mm.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US How to Order Flanges How to Order Flanges Flanges can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information and How to Order Flange Union Kits & Adapter Rings Flange Union Kits Union Kits Flange Union Kits are used to combine a male and a female flange within the same flange size code. Union Kits are available for flange sizes up to 100. The kit consists of a flange gasket and the appropriate bolts for the flange size. Order flanges separately.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information ● ● ● ● ● ● ● Type RS Strainers Stainless Steel (60 Mesh) Screen 3/8" FPT Drain Connection 20-100mm (3/4" to 8") for Safe Cleaning in Line; 1/4" FPT for 13mm (1/2") Ample Screen Area Low Pressure Drop Can Be Close Coupled to Inlet of any R/S Valve with Same Port Size Durable Filter Bags available 20-100mm (3/4" thru 4") to Aid System Clean-Up Design Pressure (MRP): 27.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US How to Order Type RS Strainers How to Order 013 025 032 050 065 075 100 125 150 200 Body Size Type Inlet Flange Outlet Flange 025 RS F08 F08 Not all flange types and sizes are available for each body size. See Connection Availability Table for allowable combinations.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Dimensions Type RS Strainers Dimensions * J dimension is space required for removal of the Strainer Screen Assembly ** Dimension C is the distance from one flange face to another. This is the space between the flanges in the line to allow the installation of the strainer.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information and How to Order ● ● ● ● ● ● ● ● Liquid Drain Ball Valves Spring Return to Close RPTFE Stuffing Box Ring All Components of Lever are Stainless Steel Nitride Corrosion Protection Blow-out Proof Stem Design Adjustable Packing Gland Investment Cast Components Multifill Seats Description These carbon steel ball valves have a “deadman” spring return handle.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information, Dimensions and How to Order ● ● ● ● Unibody Gauge Valves ASTM Forged Steel Body Stainless Steel Stem Angle or Globe Body Extended length available on inlet Angle Body Description This line of rugged all steel bodied tiny hand valves are designed to seat tight and permit isolation of small system components. The stainless steel stem has the safety feature of being non-removable.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information and How to Order ● ● ● ● ● Gauges All gauges have adjustable pointer All gauges utilize stainless steel housing and polycarbonate window over face 2½" and 3½" gauges incorporate flutter prevention mechanism 2½" and 3½" gauges are ASME Grade B 3%/2%/3% Max. Error 6" gauges are ASME Grade A 1% Max.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information Open Refrigerant Pumps GP Pump Advantages ● ● ● ● ● ● ● Proven over decades of use Designed exclusively for the delivery of primary or secondary refrigerants Driven by standard electric motor Ability to handle liquid/vapor mixture High pressure increase, low flow rate Strong construction Low maintenance ucts d o r P New The Pump Design ● ● ● ● Open impellers Lateral channels Wide channels Twin axial face sea
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information Hermetic Refrigerant Pumps Advantages of HRP pumps 1. Unrivalled Safety ucts d o r P New In contrast to most common hermetic pumps the stator housing of HRP pumps is designed to withstand high nominal pressure. If the motor “stator can” leaks in the event of an accident, no refrigerant will escape. 2.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Technical Information Spray Touch-up Paint Same blue paint pigment to match Refrigerating Specialties Division's new factory enhanced, corrosion resistant paint. ● ● ● ● Meets Auto Industry Salt Spray Test Standards Water Based Low VOL EHS Compliant Quick Drying Note: For overseas shipments, consult factory. 11 oz. Can ..........
Catalog CIC-2003-1/US Industrial Refrigeration Products: Miscellaneous General Information Industrial Refrigeration Products Warranties Safe Operation All Refrigerating Specialties products are warranted against defect in workmanship and materials for a period of one year from date of shipment from originating factory.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Temperature Pressure Data Industrial Refrigeration Products Pressure in PSIG Temp. °F °C MP39 HP80 R-401A R-402A Liquid Vapor Liquid Vapor HP62 R-404A Liquid FX10 R-408A Liquid FX56 R409A Liquid Vapor AZ20 R-410A R-22 R-123 R-134a R-502 AZ-50 R-507 R-717 -50 -45.6 — — — — 0.6 1.6 12.4 17.2 5.0 6.2 29.2 18.4 0.2 1.0 14.4 -45 -42.8 — — — — 2.7 1.1 9.7 15.2 7.0 2.7 29.0 16.6 1.9 3.0 11.
Industrial Refrigeration Products: Miscellaneous Catalog CIC-2003-1/US Temperature Pressure Data Industrial Refrigeration Products Pressure in Bar Temp. °F °C MP39 HP80 R-401A R-402A Liquid Vapor Liquid Vapor HP62 R-404A Liquid FX10 R-408A Liquid FX56 R409A Liquid Vapor AZ20 R-410A R-22 R-123 R-134a R-502 AZ-50 R-507 R-717 -50 -45.6 — — — — 0.0 0.1 315.0 436.9 0.3 157.5 741.7 467.4 5.1 0.1 365.8 -45 -42.8 — — — — 0.2 0.1 246.4 386.1 0.5 68.6 736.6 421.6 0.
Catalog CIC-2003-1/US Offer of Sale The items described in this document are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its authorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.
Parker Hannifin Corporation 6035 Parkland Blvd. Cleveland, Ohio 44124-4141 Telephone: (216) 896-3000 Fax: (216) 896-4000 Web site: www.parker.com About Parker Hannifin Corporation Parker Hannifin is a leading global motion-control company dedicated to delivering premier customer service. A Fortune 500 corporation listed on the New York Stock Exchange (PH), our components and systems comprise over 1,400 product lines that control motion in some 1,000 industrial and aerospace markets.
Contact Information Parker Hannifin Corporation Climate and Industrial Controls Group World Headquarters 6035 Parkland Blvd. Cleveland, OH 44124 USA Tel: (216) 896-3000 Fax: (216) 896-4000 www.parker.com/cig Parker Hannifin Corporation Climate and Industrial Controls Group Aftermarket Customer Service 2445 South 25th Avenue Broadview, IL 60155-3891 USA Tel: (800) 742-2681 Fax: (800) 241-2872 www.parker.com/coolparts In South America: Parker Refrigeration Division Parker Atenas Industria e Exportacao LTDA.