[SpindleOptions] Parameter Description Default
SpindleEncoderInstalled=0 Set to 1 if Spindle Encoder Equipped 0
SpindleDAMaxVoltage=9 Max Voltage for controller to Output to
spindle Drive
9
RigidTappingInstalled=0 Set to 1 if Machine Has Spindle Encoder
for Rigid Tapping
0
OrientBeforeTap=1 Set to 1 to Force an M19 on every Tap
Cycle
1
SpindleGears=2 Set to The Number of Gears on the
Spindle
2
SpindleMaxRPMGearRange0=1050 Sets Max. Speed of Gear Range 1000
SpindleMaxRPMGearRange1=4100 Sets Max. Speed of Gear Range 4000
SpindleMaxRPMGearRange2=4100 Sets Max. Speed of Gear Range 4000
SpindleMaxRPMGearRange3=4100 Sets Max. Speed of Gear Range 4000
[ToolChanger] Parameter Description Default
ChangerInstalled=0 Specifies that Machine is Equipped with a
ToolChanger
0
NumberOfToolPockets=24 Specifies Total Number of Pockets in Magazine 24
BiDirectionaMagazine=0 Set to 1 if Magazine is Bi-directional…. Used for
Shortest Path to Tool Lookup
0
VirtualPockets=0 Set to 1 for Virtual Tool Pocket Lookup Strategy
Type
0
[Speeds] Parameter Description Default
Acceleration=10 Sets Machine Acceleration 10
Deceleration=10 Set the Same as Acceleration 10
Velocity=450 Sets Machine Max Speed in inches per min. 400
Stp=10 Set the Same as Acceleration (For Trap Profile) 10
[JogSpeeds] Parameter Description Default
Acceleration=1 Sets Machine Acceleration 1
Deceleration=1 Set the Same as Acceleration 1
Velocity=100 Sets Normal Jog Speeds 100
Stp=1 Set the Same as Acceleration 1
[FastJogSpeeds] Parameter Description Default
Acceleration=1 Sets Machine Acceleration 1
Deceleration=1 Set the Same as Acceleration 1