- Parker Compact Servo Controller User Guide

Overview:
Overview of unit technology
15
Unit
hardware
Connector
assignment / cable
Technical dataConfigurationPositioning and
control functions
Optimization
functions
InterfacesAccessories /
options
StatusParameterError list
7.1.2 Overview of unit technology
COMPAX-M and COMPAX-S
!
!!
!
work with the same firmware,
yet have differences with regard to
!
housing and assembly technology and
!
power areas.
The following table shows the main features of the range of available units
Interfaces: 16 (8 with COMPAX 1000SL) digital inputs/outputs,
RS232; machine zero, limit switch, override input
Fieldbus options: RS485, Interbus-S, Profibus, CS31, CAN – Bus,
CANopen, HEDA (synchronous serial realtime interfaces)
Other options (excluding COMPAX 1000SL): absolute encoder sensor; encoder
input; encoder simulation; D/A monitor
Supply via central mains module: NMD10 / NMD20: Up to max. 3*500V AC
Dimensions (DxHxW): COMPAX P1XXM:
340*400*60 [mm]
COMPAX-M:
340*400*85 [mm]
Design:
COMPAX-M with NMD
mains module
Installation: in series
X6 X7
X8
Ready Error
RS485IN OUT
Control
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
DIGITAL
Power Supply COMPAX-M
Status
Number
X6
X8
X10
-
+
Enter
Ready
Error
RS232
Input
Output
Test
Contr ol
X9
X11
Value
DIGITAL
COMPAX-M
Power:
COMPAX ...
P1XXM: 3.8 kVA
02XXM: 4.5 kVA
05XXM: 8.0 kVA
15XXM: 17 kVA
Supply Up to max. 3 * 500V AC (integrated power unit)
Dimensions
(DxHxW): 40 * 400 * 220 [mm]
Design:
Digital
COMPAX-M
Automation
X6 X7
X8
Ready E rror
RS485IN OUT
Control
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
Power
35.0 kVA
Common function
characteristics:
COMPAX P1XXM
COMPAX 02XXM
COMPAX 05XXM
COMPAX 15XXM
COMPAX 35XXM