- Parker Compact Servo Controller User Guide

Accessories
EAM5/01: DC feed for COMPAX-M
189
Unit
hardware
Connector
assignment / cable
Technical dataConfigurationPositioning and
control functions
Optimization
functions
InterfacesAccessories /
options
StatusParameterError list
9.7.3 EAM5/01: DC feed for COMPAX-M
The power supply is normally over a central mains module; NMD10 or NMD20.
With the component EAM5/01, available as an accessory, DC voltage can be
supplied: the component contains the connections of the mains module.
Input voltage range 100V DC – 650V DC.
The DC intermediate circuit must be limited to 750V in braking mode.
Power voltage is connected directly to COMPAX-M X2
HAUSER
COMPAX-M
DIGITAL
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
DIGITAL
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
COMPAX-M
Motion & Control
COMPAX-M
Motion & Control
DIGITAL
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
UVWPE
Brake
PE+ -
X5
X1
X2
X3
X4
24V DC
0V
PE
+LS
-LS
COMPAX-M
EAM5/01 X4
Design of EAM5/01:
X6 X7
X3
X4
X8
F21
78.0 mm
68.0 mm
Note
UMK housing from Phoenix
to be attached to top hat rail of various sizes
without mating connector approx. 4.5 cm deep
Terminal assignment
The component contains the connections of the mains module.
EAM5/01 X6 = mains module X6: input bus systems
EAM5/01 X7 = mains module X7: output bus systems
EAM5/01 X3 = mains module X3: 24V DC supply
X3/3: PE
X3/2: 24V DC
X3/1: 0V
Supply voltage
for functions of
X8.