- Parker Compact Servo Controller User Guide
Accessories
EAM5/01: DC feed for COMPAX-M
189
Unit
hardware
Connector
assignment / cable
Technical dataConfigurationPositioning and
control functions
Optimization
functions
InterfacesAccessories /
options
StatusParameterError list
9.7.3 EAM5/01: DC feed for COMPAX-M
The power supply is normally over a central mains module; NMD10 or NMD20.
With the component EAM5/01, available as an accessory, DC voltage can be
supplied: the component contains the connections of the mains module.
Input voltage range 100V DC – 650V DC.
The DC intermediate circuit must be limited to 750V in braking mode.
Power voltage is connected directly to COMPAX-M X2
HAUSER
COMPAX-M
DIGITAL
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
DIGITAL
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
COMPAX-M
Motion & Control
COMPAX-M
Motion & Control
DIGITAL
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
UVWPE
Brake
PE+ -
X5
X1
X2
X3
X4
24V DC
0V
PE
+LS
-LS
COMPAX-M
EAM5/01 X4
Design of EAM5/01:
X6 X7
X3
X4
X8
F21
78.0 mm
68.0 mm
Note
♦
UMK housing from Phoenix
♦
to be attached to top hat rail of various sizes
♦
without mating connector approx. 4.5 cm deep
Terminal assignment
The component contains the connections of the mains module.
EAM5/01 X6 = mains module X6: input bus systems
EAM5/01 X7 = mains module X7: output bus systems
EAM5/01 X3 = mains module X3: 24V DC supply
X3/3: PE
X3/2: 24V DC
X3/1: 0V
Supply voltage
for functions of