- Parker Compact Servo Controller User Guide

External data record selection
227
11.1.2 External data record selection
Application:
One of eight various workpieces should be made available at a data collection station. The number of the
desired workpiece is set using a BCD selector switch. The transportation process is then triggered by a
starting pulse.
Assignments:
station
7
removal
station
station
6
station
5
station
4
station
3
station
2
station
1
station
0
+960
+840 +720 +600 +480 +360 +240 +120 0 -60
workpiece pick-up
The horizontal movement is implemented using an NC axis controlled by COMPAX. A pneumatic cylinder,
which is controlled by COMPAX using a double solenoid valve, raises and lowers the workpiece pick-up.
COMPAX performs all the functions required without superordinate control.
Wiring up the digital inputs and outputs:
I1
I2
I5
I6
I10
I11
I12
I13
O7
O8
I9
I14
I15
I16
search MZ
start
stop
BCD-switch
I7
I8
pick-up lifted
pick-up lowered
lower
pick-up
lift
pick-up
evaluation by
external calling
of command lines
removal
station empty
1
2
4
BCD
+24V +24V
+24V
COMPAX
+24V
Comments:
The inputs I9, I14, I15 and I16 have to be placed on GND or left open.
The BCD switch has eight settings. The outputs are encoded with binary.
The "Data collection station empty" switch is closed when the data collection station is closed. The switch
operation prevents the workpiece pick-up being lowered for as long as there is a workpiece in the data
collection station.
Function:
The first event after COMPAX has been started is the approaching of the data collection station. If the
workpiece pick-up is not lowered, the assumption is made that there is still a workpiece in the workpiece
pick-up. This is deposited in the data collection station by lowering the workpiece pick-up. The system is now
ready for the first transportation process.