- Parker Compact Servo Controller User Guide

COMPAX 35XXS unit features
Installation and dimensions of COMPAX 35XXM
27
Unit
hardware
Connector
assignment / cable
Technical dataConfigurationPositioning and
control functions
Optimization
functions
InterfacesAccessories /
options
StatusParameterError list
L1 L2 L3
PE
PE
PE
+
-
U
VW
PE
+
-
F1
Mains Input
DC - In
Braking
Motor
Motor
X 20
24 V
X 21
Resistance
X 22 X 1
Brake
X 23
motor
AC - voltage
up to 500V AC
24V control
voltage
external
ballast
resistor
motor
brake
F1
3.16A
Supply voltage up to max. 3 * 500V AC
Operating range: 3*80V AC - 3*500V AC; 45 - 65 Hz.
Typical AC mains: 400V ±10%; 460V ±10%;480V ±5%
!
Layout of contactors for the power supply:
Capacity according to device performance: Application group AC3
Switching on the operating voltage for a second time:
Before switching on the operating voltage for a second time, you must wait for at
least 2.5 minutes otherwise you may overload the condenser load resistance.
Control voltage
!
21.6V to 26.4V DC
Ripple: < 1V
SS
fuse protection: max. 16A
Mains supply fuse protection
62A K circuit breaker or suitable Neozed conventional fuse.
Regeneration mode
!
Storable energy: 3450µF/542 Ws
!
External ballast resistance: 10
/2 kW
For the external ballast resistors available, please see Page 193.
7.4.2 Installation and dimensions of COMPAX 35XXM
390
340
86
65 65
218
190
450
363
190
430
10
14
38
Digital
COMPAX-M
X5 X7
IN OUT
X19
Control
H1
X6
Input
Output
Status
Value
+-Enter
Ready Error
RS 232
Test
Control
X8 X10
X9 X11
Number
Fastening with 4 M6 hex-socket head screws.
Plan view
Specific technical
data
Note!