7.5.3 COMPAX 25XXS dimensions / installation
The two retaining plates supplied can be attached to the back/left side or the heat
sink side. Retaining screws: 4 M6 hex-socket head screws.
290
Status Number
X6
X8 X10
-+Enter
Ready Error
RS232
Input
Output
Test
Control
X9 X11
Value
98
130
270
240
10
30
16
65
65
221
271
98
COMPAX-S
The left-hand side of the unit heat sink is fastened to a metal wall using 2 retaining
plates.
Installation distance: 135mm (device distance:5mm)
Delivery status
The design is delivered ready for connection in series!
The left-hand side of the unit heat sink is fastened to a metal wall using 2 retaining
plates.
Status Number
X6
X8 X10
-+Enter
Ready Erro r
RS232
Inp ut
Output
Test
Control
X9 X11
Value
186
270
240
290
10
30
186
220
65
65
131
181
17
95
COMPAX-S
! Install the retaining plate on the required side.
! Unfasten front plate and blind plate. There are 2 screws on both the upper and
lower sides of the unit.
Install the front plate and then the blind plate at the required point.
Design in series
Flat design
Converting the