- Parker Compact Servo Controller User Guide

Configuration
Front plate operation (not available with COMPAX 1000SL)
71
Unit
hardware
Connector
assignment / cable
Technical dataConfigurationPositioning and
control functions
Optimization
functions
InterfacesAccessories /
options
StatusParameterError list
8.2 Configuration
8.2.1 Front plate operation (not available with COMPAX 1000SL)
Using the COMPAX front plate, you can query particular status values and perform
the most important bus settings. Also whenever an error occurs, COMPAX shows
the error number on the display.
call smaller
Status
number
without
function
decrease
value
increase
value
choose
Status
number
choose
number of
C-parameter
status
indicator
change
C-parameter
without
function
call higher
Status
number
call smaller
C-parameter
number
call higher
C-parameter
number
Enter
Enter
Enter
A
Enter
B
A
B
Enter
Enter
choice of operation
modes
The following status values can be displayed via the front plate:
S03-S08, S11, S19-S26 (hexadecimal display), S27, S30, S31, S37-S39
(description of the status values: see Page 207).
The remaining status values can be queried via the interfaces.
C parameters COMPAX parameters Meaning Valid from
C01 P194 Address of unit Power on
C02 P195 Baud rate: Power on
C03 P196 Bus protocol Power on
C11 P250 HEDA address immediately
C04 - C10 reserved
Display
value
Baud rate
[Baud]
Display
value
Baud rate
[Baud]
Display
value
Baud rate [Baud]
0 600 31 31 250 172 172 800
1 1200 38 38 400 187 187 500
2 2400 50 50 000 250 250 000
4 4800 57 57 600 345 345 600
9 9600 62 62 500 375 375 000
10 10 000 76 76 800 500 500 000
19 19 200 100 100 000 800 800 000
20 20 000 115 115 200 999 1 000 000
28 28 800 125 125 000
Please see operating instructions for the bus option used for the relevant
range of values and the precise setting options.
Once you have rectified the cause of the error, you can acknowledge the error by
pressing the "Enter" key.
Querying status
values and
modifying the
bus parameters.
Meaning of the
bus parameters:
Acknowledging
error messages