Conversion from Natural to
LPG Gas
IMPORTANT
The replacement/conversion of the gas hob
should only be undertaken by a CORGI
registered engineer.
It is important to note that this model is designed
for use with natural gas but can be converted for
use with butane or propane gas providing the
correct injectors are fitted. The gas rate is adjusted
to suit.
Method
Ensure that the gas taps are in the 'OFF' position
Isolate the hob from the electricity supply
Remove all pan supports, burner caps, rings,
crowns and control knobs.
With the aid of a 7mm box spanner the burner
injectors can then be unscrewed and replaced
by the appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver undo the
by pass screw about 1/4 of a turn (45°). Upon
completion stick the replacement rating plate near
the gas supply pipe.
Replacement of gas oven
burner nozzle
To replace the gas oven nozzle, follow this proce-
dure:
a) remove the bottom of the oven;
b) undo screw 1 and take the oven burner out;
c) with a socket spanner 7 unscrew and remove
the nozzle, situated in the bottom of the oven,
and replace it with the proper one (see Table on
page 18);
d) reassemble the burner following the same pro-
cedure backwards.
FO 1061
Minimum level adjustment
of gas oven burner
After setting the oven on maximum temperature
with door closed for about 10 minutes, turn the
knob on minimum.
To reach the thermostat by-pass screw and adjust
the minimum level, act as follows:
take out the knobs;
remove the front panel;
in case of conversion from natural gas to LPG,
tightly screw the by-pass screw of thermostat
(see fig.);
to convert from LPG to natural gas, unscrew
the by-pass screw, until a regular small flame
is reached.
finally check that turning quickly the tap from
maximum position to minimum position, the
flame does not go out;
reassemble the front panel and the knobs.
The oven burner does not need any primary air
regulation.