PRESSURE CLEANER PHD 150 A1 PRESSURE CLEANER Translation of original operation manual 6 55991_par_Hochdruckreiniger_Cover_LB6.indd 20 29.10.
Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. GB / IE Translation of original operation manual 55991_par_Hochdruckreiniger_Cover_LB6.indd 21 Page 4 29.10.
A 1 2 12 3 4 5 11 13 16 15 10 6 7 9 14 8 1 17 18 12 19 B 1 20 21 22
GB IE Content Notes on Safety Notes on Safety .....................................4 Symbols in the manual ......................4 Explanation of symbols ......................4 General notes on safety .....................5 Areas of Application ..............................6 General Description ..............................6 Overview ............................................7 Functional description ........................7 Scope of Delivery ...............................7 Start-up ..............
GB ≥100A The equipment is intended only for use in premises in which the current bearing capacity of the network is >=100 A per phase and which are supplied by a distribution grid with a nominal voltage of 400/230V. Safety class II Electric appliances should not be disposed of in the domestic garbage.
GB • • IE Use only original accessories and do not carry out conversion work on the equipment. Please read the notes in the operating instructions on the topic of “maintenance and cleaning”. Any measures above and beyond these, particularly opening the equipment, are to be carried out by an electrician. In the case of repairs, always contact our service centre.
GB Overview A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Jet gun Carrying handle High-pressure hose on reel Hose reel crank Cable hook Mains lead Wheels Strainer frame Water supply On/Off switch Jet gun holder High-pressure fitting (gun) Opening of cleaning agent tank Quick-action water supply connector Cleaning agent tank Accessories holder Jet tube w/ high-pressure nozzle Jet tube w/ flat spray nozzle Rotating brush Nozzle cleaning pin Cleaning agent Functional description The pressure wash
GB • • IE The jet tube with high-pressure nozzle (17) produces a rotating water jet and is designed for low water consumption work. Operation • Turn on the water tap entirely. Never operate the pressure washer with a closed water tap. Dry running will damage the washer! The jet tube with flat spray nozzle (18) produces a flat wide jet particularly suited for large surfaces.
GB Interrupting operation • • • Release the lever of the gun (1). During prolonged work intervals turn off the washer by its ON / OFF switch (10). Ending operation • • • • • • • After having worked with a detergent rinse the washer with clear water. Release the lever of the gun (1). Turn off the pressure by its ON / OFF switch (10). Turn off the water tap. Disconnect the pressure washer from the water mains. Pull the lever of the gun (1) to vent the pressure existing within the system.
GB IE Maintenance Guarantee Notes The pressure washer is maintenance free. • Ask our service centre to carry out any work that is not described in these instructions. Use only original parts. • Storage • • • Drain all the water from the pressure washer. Disconnect the unit from the water supply. Press the On/Off switch (10) to turn on the pressure washer for no longer than 1 minute until no more water escapes from the jet gun(1) or from the attaching parts (17/18/19). Turn off the unit.
GB IE Technical data Spare Parts Order Pressure Washer ................PHD 150 A1 Mains connection.................230V~, 50 Hz Power consumption ...................... 2100 W Mains cable .........................................5 m Weight (without accessories)......... 10,8 kg Safety class ......................................... II Degree of protection .......................... IPX5 Inflow temperature t, max. .................40°C Inflow pressure p, max. ...............
GB IE Trouble shooting Problem Washer is not operating Washer does not generate any pressure Severe pressure fluctuations 12 Possible cause Remedy ON / OFF switch is turned off Check ON / OFF switch Damaged power supply cable Check power supply cable for damage. If necessary have the power supply cable replaced by a qualified electrician. Mains fault Check the electrical system for conformity with the data on the rating plate.
GB EU declaration of conformity IE We hereby confirm that the Pressure Washer Design Series PHD 150 A1 Serial number 201010000001 -201010110000 conforms with the following applicable relevant version of the EU guidelines: 2004/108/EG • 2000/14/EG • 2006/42/EG In order to guarantee consistency, the following harmonised standards as well as national standards and stipulations have been applied: EN 60335-1/A13:2008 • EN 60335-2-79:2009 • EN 62233:2008 • EN 55014-1:2006 EN 55014-2:A2:2008 • EN 61000-3-2:20
Grizzly Service-Center DES UK Ltd. Unit B7 Oxford Street Industrial Park Vulcan Road Bilston, West Midlands WV14 7LF Tel: 0870 7876177 Tel from Ireland: 0044 870 787 6177 Fax: 0870 7876168 Fax from Ireland: 0044 870 787 6168 Email: grizzly@deslimited.
IAN 55991 Grizzly Gartengeräte GmbH & Co. KG Am Gewerbepark 2 D-64823 Groß-Umstadt Last Information Update: 10 / 2010 Ident.-No.: 75040120102010-6 55991_par_Hochdruckreiniger_Cover_LB6.indd 19 6 29.10.