Installation Manual
Table Of Contents
- A. Safety Information 3
- B. Other Conventions 5
- A. Overview of Installation 7
- B. Required Materials (Not Supplied) 7
- C. Design the Installation 7
- D. Install the Battery Charger 9
- E. Install the Order Point Speaker and Microphone Assemblies 12
- F. Install the Vehicle Detector(s) 13
- G. Assemble the PAR Drive Thru Headset G5. 13
- H. Install the Basestation 15
- I. Connect the Components 17
- J. Basestation to Component Wiring 20
- K. Auxiliary Detector Relays 21
- L. Installing Accessory Boards in the Basestation 23
- M. Power Up 26
- A. Enter Configuration Mode 28
- B. Navigating the Basestation Display 28
- C. Finding the MAC Address of the G5 Basestation 30
- D. Configuring with a Computer 30
- E. Logging into the Base Station with a PC 31
- F. Switching Between Lane1 and Lane2 31
- G. Menu Options for Lane1 and Lane2 32
- H. Change Basic Volume Settings 33
- I. Change Noise Reduction Level 39
- J. Set System Date and Time 39
- K. Change Global Settings 39
- L. Haptics “Vibration” Alerts and Blue LED Alerts on Headsets 42
- M. Order Taking Modes Setup 43
- N. Change Site Scheduling 43
- O. Change Site Information 44
- P. Digital IO Setup 45
- Q. Change Passcodes 45
- R. Split and Cross Lane Mode 46
- S. Installer Setup 46
- T. Factory Setup (Restore Factory Defaults) 47
- U. Create and Load Templates 47
- V. Reboot System 47
- W. Check the Revision Levels 48
- 1. Overview
- 2. Installation
- A. Overview of Installation
- B. Required Materials (Not Supplied)
- C. Design the Installation
- D. Install the Battery Charger
- E. Install the Order Point Speaker and Microphone Assemblies
- F. Install the Vehicle Detector(s)
- G. Assemble the PAR Drive Thru Headset G5H1
- H. Install the Basestation
- I. Connect the Components
- J. Basestation to Component Wiring
- K. Auxiliary Detector Relays
- L. Installing Accessory Boards in the Basestation
- M. Power Up
- 3. Configuration
- A. Enter Configuration Mode
- B. Navigating the Basestation Display
- C. Finding the MAC Address of the G5 Basestation
- D. Configuring with a Computer
- E. Logging into the Basestation with a PC
- F. Switching Between Lane1 and Lane2
- G. Menu Options for Lane1 and Lane2
- H. Change Basic Volume Settings
- Inbound Microphone Volume
- Outbound Talk Volume
- Vehicle Alert Volume
- Outbound Greeter Message Volume
- Change the Monitor Volume
- Inbound Listen
- Outbound Talk
- Vehicle Present
- Vehicle Approach
- Page Messages
- Greeter Messages
- Monitoring Audio Separately for the Two Lanes
- Change the Night Volume
- Registering Headsets
- Add Headsets
- Remove Headsets
- List All Headsets
- Resetting Inactive Days
- Checking Headset Software Revision
- Identifying Headset Serial Number
- I. Change Noise Reduction Level
- J. Set System Date and Time
- K. Change Global Settings
- L. Haptics “Vibration” Alerts and Blue LED Alerts on Headsets
- M. Order Taking Modes Setup
- O. Change Site Information
- P. Digital IO Setup
- Q. Change Passcodes
- R. Split and Cross Lane Mode
- S. Installer Setup
- T. Factory Setup (Restore Factory Defaults)
- U. Create and Load Templates
- V. Reboot System
- W. Check the Revision Levels
- X. Change the Microphone Preamp Gain
- Y. Installer Access
- 4. Troubleshooting
- 6. Appendix: Basestation Specifications
- 7. Appendix: Induction Loop and Vehicle Detector Board Specifications
- 8. Appendix: G5 Charger Specifications
- 9. Appendix: Best Practices
- 10. Appendix: PAR Acoustic Kit Installation Guide
- 11. Appendix: Loop and Cable Condition Test
- 12. Appendix: Upgrading a Single Lane Basestation to a Dual Lane
- 13. Index
Installation Instructions G5 Release A
47
•
Change the value for
Save Installation Settings
to
Yes
.
Technical Service Message
Perform the following procedure to customize the Service Screen message.
•
Enter the configuration mode, see “Enter Configuration Mode” on page 28, and choose
1 System Menu
.
•
Select
14 Installer Setup
.
•
Change the value for
Use Custom Tech Service Message?
to
Yes
or
No
.
•
If you chose
Yes
, enter the customer message.
Number of Basestations at this Site
The G5 Basestation Model G5B1 can function as a Single or Dual Lane system. Perform the following procedure to
enable the basestation to operate as a dual lane or single lane system:
•
Enter the basestation configuration mode, see “Enter Configuration Mode” on page 28, and choose
1 System
Menu
.
•
Change the value for
14 Installer Setup
>
Number of Lanes At This Site
to
2
.
(or to
1
if this is a dual lane system but being installed to function on a single lane)
•
Press
Enter
to implement the change.
IMPORTANT NOTE
The G5 Basestation displays this option only when it’s Dual Lane functionality has been activated.
The Dual Lane functionality on the G5 Basestation Model G5B1 is not active, by default, when purchasing a
new system. Dual Lane functionality on the G5 Basestation Model G5B1 must be activated by calling
1-800-328-0033
.
T.
Factory Setup (Restore Factory Defaults)
Perform the following procedure to restore all of the configuration settings to the factory default settings. This
procedure should be performed only if the current configuration and the saved installation settings are unusable.
IMPORTANT NOTE
By performing this procedure you will reset the system to the initial configuration, making it impossible to revert
to the settings that were saved after installation.
•
Enter the configuration mode, see “Enter Configuration Mode” on page 28, and choose
1 System Menu
.
•
Select
15 Factory Setup
.
•
Change the value of
Restore All Factory Settings
to
Yes
.
•
The system will then reboot.
U.
Create and Load Templates
You can save an entire base station configuration as a file on a PC and use the file as a template for other base stations.
You must be using a PC to use templates.
V.
Reboot System
Perform the following procedure to cleanly power down, then power up without unplugging the system:
•
Enter the configuration mode, see “Enter Configuration Mode” on page 28, and choose
1 System Menu
.
•
Select
17 Reboot System
.
•
Change the value of
Power Cycle Complete System
to
Yes
.