Data Sheet
Table Of Contents
- Boron Datasheet (v008)
- Functional description
- Interfaces
- Memory map
- Pins and button definitions
- Technical specifications
- Mechanical specifications
- Recommended PCB land pattern
- Schematic
- Country compatibility
- Ordering information
- Qualification and approvals
- Product Handling
- Default settings
- FCC IC CE Warnings and End Product Labeling Requirements
- Revision history
- Known Errata
- Contact
SystemRGBLED
ForadetailedexplanationofdifferentcolorcodesoftheRGBsystemLED,pleasetakealook here.
ChargestatusLED
State Description
ON Charginginprogress
OFF Chargingcomplete
Blinkat1Hz
Faultcondition
[1]
Rapidblinking
Batterydisconnected
[2]
Notes:
[1]
Afaultconditioncanoccurduetoseveralreasons,forexample,batteryover/undervoltage,
temperaturefaultorsafetytimerfault.Youcanfindtherootcausebyreadingthefaultregisterof
thepowermanagementICinfirmware.
[2]
YoucanstopthisbehaviorbyeitherpluggingintheLiPobatteryorbydisablingchargingusing
firmwarecommand: PMIC().disableCharging(); .
LEDSTATUS