User's Manual

Installation – Keypads
Page | 1
x Use standard electrical boxes or low voltage rings to mount the keypads.
Connect the keypad hub to the master controller/amplifier using a standard
Ethernet patch cable.
x Although the DAX88 Keypad Hub is labeled as 1 8 for each of the 8 ports, the
dip switches on the back of the keypads must be set so they correspond to the
correct zone like the chart below shows. This gives each keypad a distinct
address. The up position is ‘ON’, whereas the down position is ‘OFF’ This chart is
also found on each keypad for ease of installation. The example on the right has
the correct settings for “Zone 3”. If you do not complete this step for each
keypad, your keypads will not control the correct zone.
Zone
1
2
3
Zone 1
ON
ON
OFF
Zone 2
ON
OFF
ON
Zone 3
ON
OFF
OFF
Zone 4
OFF
ON
ON
Zone 5
OFF
ON
OFF
Zone 6
OFF
OFF
ON
Zone 7
OFF
OFF
OFF
Zone 8
ON
ON
ON