2” Quick Set Shower Drain
For Fiberglass Shower Stalls
Internal locknut and gasket for 2” DWV
Brass body and locknut
Stainless steel strainer
PART
NUMBER
PIPE
SIZE
7980 2”
Use in fiberglass or plastic showers
Clear visual instructions to remove the old drain
Shower tear-out eliminated
Fits 2” ABS & PVC Pipe
Most repairs done in less than 30 minutes
Allows one-person shower installations
Drain installs AFTER shower stall is set
WingTite Shower Drain
PART
NUMBER
SD1000
1
2
3
4
5
6
7
8
With hacksaw, make two
vertical cuts approximately
1” apart through drain body.
Cut completely through
drain body without cutting
into shower pan or scoring
pipe riser.
Continue cutting horizontally
through drain flange to
weaken it, but not deep
enough to damage pan.
Once horizontal flange is cut,
use flat blade screwdriver to
pry on 1” flange to break free
from shower pan.
Remove 1” width of the drain
from pan.
Squeeze the shower drain to
collapse it, this allows the
retaining nut below shower
base to drop. Nut stays below.
Remove shower drain from
pan. Clean shower surface
around drain hole, above and
below the pan to insure proper
seal and unrestricted wing
movement.
Cut
Here