Instructions / Assembly

11
Installing Metering Valve to Fuel Cell Prior to Use
To install the metering valve to a fuel cell:
1. Press downward on the front side of the valve (stem side) until it seats.
2. Press downward on the rear side of the valve until it seats.
3. The valve is now completely seated onto the fuel cell and can be inserted into the tool.
DANGER
Paslode Cordless Fuel Cells are flammable.
Do not smoke when installing the metering valve!
1. 2. 3.
NOTE:
Paslode Cordless Fuel Cells are marked with an expiration date on the bottom of the cell.
For maximum performance use fuel before expiration date.
Fuel Cell and Metering Valve