Instructions / Assembly
12
Inserting Fuel Cell
Inserting the metering valve/fuel cell assembly into the
Cordless Finish Nailer is very simple. To begin, press up at
the bottom of the actuator cover and pivot outward to open.
The cover will swing out of the way.
Next, with the metering valve stem pointed toward the front
of the tool, insert the metering valve/fuel cell assembly.
As you slide the metering valve/fuel cell assembly into the
Cordless Finish Nailer, you will notice a
yellow adapter at
the top of the cylinder pocket. As shown in the illustration,
this adapter is designed to ensure that the metering valve
stem is properly aligned with the small hole, or orifice, that
leads to the combustion chamber. Insert the metering valve
stem into the orifice of the yellow-colored adapter.
Fuel Cell and Metering Valve
Close the actuator cover to complete the loading of fuel in
the Cordless Finish Nailer. Do this by swinging it up and
over the metering valve/fuel cell assembly, and pushing
down until the actuator cover snaps into position.
➔
1. PRESS UP
➔
1. SWING BACK
Fuel Cell
Yellow
Adapter
Metering Valve Stem
Yellow Metering
Valve
2. PULL OUT
➔
2. PUSH DOWN
➔