You can position this amplifier most anywhere you wish, but it re-
quires adequate ventilation. We do not recommend placing it in
enclosed cabinets or small closets without means for air to circulate
freely. Stacking these power amplifiers directly upon each other is not
recommended for the same reason. T his amplifier typically idles at
slightly less than 350 watts, most of which dissipates as heat across
the heatsinks. As a point of reference, these heatsinks should never
become too hot to touch for several seconds.
Let’s talk about AC power requirements. This amplifier draws about
3 amps (continuous r ms) at 120 volts out of the wall during nor mal
operation, and this power draw ref lects mostly the idle cur rent that
we r un through the output stag e. If you are driving a low impedance
load, you will draw more power than this, but this will not be typical.
The amplifier’s voltage and cur rent rating are indicated on the rear
panel. It will be 240 volts, 220 volts, 120 volts or 100 volts, all with
an appropriate rear mounted resetable circuit breaker. T he frequency
rating of the AC line source in all instances will be 50 to 60 Hz. Please
verify that the amplifiers indicated voltage requirements are consistent
with the line voltag e supplied at your location.
The Pass Laboratories™ X250.5 is provided with a conventional IEC
detachable AC line cord, which is rated at 15 amps. The safety ground
is attached to the chassis in the conventional approved manner. T he
AC power input to the amplifier r uns through a RF filter, which re-
moves high frequency noise coming into and g oing out of the ampli-
fier power supply.
Under no circumstances should you defeat the g round connection of
the power cord. For your safety, the chassis of the amplifier should be
earth g rounded. Signal g round is isolated from chassis, safety ground,
to reduce the incidence of g round loop noise. T he presence of a
safety g round will not deg rade the audio signal chain.
You may substitute an after market detachable IEC 320 style power cord
of your choosing; provided it is rated for at least 15 amps and it meets all
leg al requirements and has been approved by the local testing authority
for such things.
Looking at the rear panel you will see the IEC 320 AC power cord
receptacle, a ther mal magnetic breaker switch, two pairs of output con-
nectors, a pair of binding post connectors for remote turn-on, one RCA
input connector and one XLR balanced input connector.
Make sure that the breaker switch is off (down). Plug the AC cord into
Setup