Data Sheet

Max.
T
yp
.
Conditions
Max.
Conditions
Model EHV-M2
No.EHV-W18F-2_18
Outer Dimensions Refer to 6. Outer Dimension Drawing
Rated Voltage
A
C90 V-AC264 V (50/60 Hz)
5.3 W (at AC240 V)
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.
1.25 kg
Upright position from horn opening at a distance of 1 m.
Volume at maximum and "Stutter" alarm played.
Remarks
UL Listed (File No.S24210)
15 A or less (at AC240 V)
Rated Power
Consumption
(for NPN/No-voltage)
Volume at maximum and a 1 kHz at -6 dB sinusoidal wave played back
Inrush Current
Operating Ambient Temperature
23 A or less (at AC264 V)
Operating Ambient Humidity Less than 85 % (No condensation)
-20
to +50
Impact Resistance
Less than 85 % (No condensation)
Indoors/Outdoors
Mounting Direction
45.0 m/s
2
IEC 60068-2-6:2007
(
U
p
ri
g
ht Position
)
Maximum: 110 dB
Withstand Voltage
Insulation Resistance
Mounting Location
More than 1 M at 500 VDC between the terminals and the chassis
1500 VAC applied for 1 min between terminals and chassis without breaking insulation
IEC 60068-2-27:2008 (Upright Position)
250 m/s
2
6 ms for 1,000 times (3 axis 1 direction); 500 m/s
2
11 ms for 3 times (3 axis both directions)
Vibration Resistance
Upright
Upright Installation
Mass (Tolerance: ±10%)
FCC Part15 Subpart B Class
KC (KN22, KN24)
UL 464, CSA-C22.2 No. 205-M1983
Compliance Standards
Environmental Conditions
Sound Pressure level (MP3) Maximum: 105 dB
7.9 W (at AC264 V)
Sound Pressure Level (Alarm)
Environmental Conditions
Volume at maximum and a 1 kHz at -6 dB sinusoidal wave played back from the horn opening.
A
C100 V-AC240 V (50/60 Hz)
6 A or less (at AC100 V)
Environmental
Condition
Sideways Upside-down
IP65 (IEC 60529)
Operating Voltage Range
Rated Current Consumption
Protection Rating
150 m
A
A
t maximum volume and "Rapid Hi-Lo" alarm playback
Storage Ambient Humidity
Storage Ambient Temperature -30
to +60