Data Sheet

LA6-W18D-12_26
4.2. Current Capacity
Table 1 Signal Contact Capacity
Current Capacity 100mA or more
Withstand Voltage DC 35V or more
Leakage Current 0.1mA or less
ON Voltage (Vsat) 1V or less
Table 2 Power Supply Inrush Current
Inrush Current Value 16A/5us
Table 3 Supply Current
Model Current
LA6-3D
N 170mA
LA6-3D
B 210mA
LA6-5D
N 260mA
LA6-5D
B 300mA
24V DC
Class2
No polarity
LA6
Relay
PLC (NPN)
/
Each LED/Alarm
1
Input
1 - 7
1
/
Do not connect!
24V DC
Class2
PLC (PNP)
24V DC
Class2
16 A , 5 µsec
Inrush Current
External Contact Classication
Voltage Contact Relay or PLC
Without flashing/alarm
BN
With flashing/alarm
Flashing/Pulse Enable
Common line
/
/
/
Power Supply Wire
Mode Change
2
Power Supply Wire
B
Pink
1 Flashing/Alarm type only.
2 There is no inrush current on the wire
for “Mode Change.
Each Color
Pink
Yellow
Gray
Brown