Choose a mode by sliding the switch at the back of sensor lens. When power is first applied, the light will turn on
immediately. Wait for 100 seconds to allow the sensor to warm up.
1. Test MODE (daytime and nighttime operation.)
• The light will turn to low-level brightness (0~50%).The light will turn to high-level brightness (full brightness) when
motion is detected, and stay on as long as the motion continues. The light will revert to low-level brightness you set
about 5 seconds after motion is no longer detected.
2. Off MODE (nighttime operation only)
• At dusk, the light will turn to high-level brightness (full brightness) when motion is detected, and stay on as long as
the motion continues. When the motion stops, the light will remain on for the predetermined time set
(5 ~ 180 seconds), then the light will turn off automatically.
3. Auto MODE (nighttime operation only)
• At dusk, the light will turn to low-level brightness (0~50%). The light will turn to high-level brightness (full brightness)
when motion is detected, and stay on as long as the motion continues, When the motion stops, the light will remain
on for the predetermined time set (5~180 seconds), and then revert to low-level brightness you set.
• The light will turn off automatically at dawn.
4. PC MODE (nighttime operation only)
• The light will turn to high-level brightness (full brightness) at dusk. It will turn off at down.
Customization Options
Shut-off Delay
The Shut-off delay is the length of time the light will stay at high-level
brightness after motion has ceased to be detected. This Shut-off delay
can be set when operation is in “Off”, or “Auto” mode by using the
“Time” knob located on the left side of the panel at the back of sensor
head (See Fig.10) . To increase the shut-off delay, turn the knob
clockwise. To decrease shut off delay, turn the knob counterclockwise.
The delay may be adjusted from a minimum of 5 seconds to a maximum
of 3 minutes. The light will stay on as long as motion is detected
continuously and will automatically turn to low-level brightness when no
more motion is detected after the delay time has passed.
Fig. 10
Test
Off
Auto
PC
Low Level
(View from back of sensor head)
Time
Sens
Model
5. Manual Override MODE (nighttime operation only)
• To shift to the manual override mode, Set the switch to “Off” or “Auto”
mode. Turn the wall switch “OFF” and then turn it “ON” within 3
seconds. The light will remain on all night long. To shift back to the
“Off” or “Auto” mode, turn the wall switch “OFF” and then turn it “ON”
within 3 seconds again. (See Fig.9)
• The light will last only for one night and turn off automatically at dawn.
Note: 1. You can adjust the low level brightness (0~50%) by rotating
“Low Level” knob at the back of sensor lens. (See Fig.10)
2. To make sure the above functions operate properly, always
keep the wall switch in the “ON” position ( including the daytime).
3. Please notice the warm up time is 100 seconds, ant operations are invalid during this time.
Off Mode
Auto Mode
Manual
Override
Manual Override Operation Diagram
Turn wall switch OFF-ON
in 0.5~3 Seconds
Turn wall switch OFF-ON
in 0.5~3 Seconds
Fig. 9
Step 1: Rotate the sensor lens counterclockwise to show
up the adjustable knobs and slide switch.
(See Fig.1)
Step 2: Turn the knobs to adjust time, low level brightness
and sensitivity. And slide the slide switch to choose
desired mode. (See Fig.2 and Detail A view).
Step 3: Rotate the sensor lens clockwise to restore original
position.(See Fig.3)
“Time” Knob
“Sens” Knob
Slide Switch
“Low Level” Knob
Time Low Level
Sens
Test
Off
Auto
PC
Detail A View