USER MANUAL VLINK MODEM Model 1068 and 1058 Part# 07M1068-UM Doc# 05816U2-001 Rev.
CONTENTS 1.0 1.1 1.2 1.3 Warranty Information ................................................................. Radio and TV Interference (FCC Part 15) .................................... CE Declaration of Conformity ....................................................... Service.......................................................................................... 4 4 4 5 2.0 2.1 2.2 General Information.................................................................... 6 Features..................
Terminal Block (1068DV/TB45 Only) ......................................... 24 C.3 POTS/ISDN Interface .................................................................. 24 RJ-45 .......................................................................................... 24 D Distance Chart, Based on 24 AWG (0.5 MM) ..........................
1.0 WARRANTY INFORMATION Patton Electronics warrants all VLINK modem components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device. This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment. WARNING 1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics.
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability WARNING In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling. 2.
• Available in rack-mount or standalone configurations • Made in the USA 2.2 DESCRIPTION The Patton Electronics VLINK/CO and VLINK/CP VDSL modems provide high-speed LAN connections between peered Ethernet LANs, remote PCs, or any other network enabled 10/100Base-T device.
3.0 INSTALLATION Because the VLINK modem requires no configuration, it can be installed quickly. If you are installing a standalone unit, refer to section 3.1 “Standalone unit installation”. Otherwise, refer to section 3.2 “Rack card installation”. Note If asymmetric transmission or line rates other than 12.5 Mbps are required, refer to section 4.0, “Configuration” on page 13. 3.1 STANDALONE UNIT INSTALLATION Do the following: 1. Connect the line interface between the units (refer to section 3.
3.2 RACK CARD INSTALLATION The VLINK modem rack card comprised a front card and a rear card.Do the following to install the cards into the rack chassis: 1. Slide the rear card into the back of the chassis along the metal rails. 2. Secure the rear card using the supplied metal screws. 3. Slide the front card into the chassis until you feel resistance as the front card engages the rear card.
6. Connect the Ethernet interface (refer to section 3.4, “Connecting the 10/100Base-T Ethernet Interface” on page 11). 3.3 CONNECTING THE TWISTED-PAIR LINE INTERFACE The VLINK modem supports communication between two peer Ethernet LAN sites over a distance of up to 6,000 ft (1.83 km) over 24 AWG (0.5 mm) twisted-pair wire. Note Actual distance and link performance may vary depending on the environment and type/gauge of wire used. Follow the steps below to connect the VLINK modem VDSL interfaces.
The terminal block connector on the VLINK modem's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationships is shown in Figure 5. A de in the US Ma et rn he Et r we Po e Lin N ISD / TS PO Figure 5. VLINK modem (terminal block version) twisted pair line interface (Model 1068DV/TB45) 3.4 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE The unshielded RJ-45 port labeled Ethernet is the AutoMDIX10/100Base-T interface.
3.5 CONNECTING THE POTS/ISDN LINE The RJ-45 port labeled “POTS/ISDN” is the POTS/ISDN interface. A telephone or an ISDN device may be connected to this port and carried over the VDSL line. The units do not need power for the POTS interface to work. The RJ-45 connector in the VLINK modem’s POTS/ISDN interface is wired as shown in Figure 7. 1 (no connection) 2 (no connection) 1 2 3 4 5 6 7 8 3 (no connection) 4 (2-wire RING) 5 (2-wire TIP) 6 (no connection) 7 (no connection) 8 (no connection) Figure 7.
4.0 CONFIGURATION The Model 1068 VLINK modem has eight DIP switches for configuring the unit for a wide variety of applications. This section describes switch locations and explains the different configurations. No dip switch options are available on the 1058. 4.1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat-tip screwdriver, remove the protective cover located on the underside of the VLINK modem (see Figure 8). Figure 8.
Figure 9. Model 1068 standalone modem DIP switch orientation S1 K Mo de m Po w VL er IN K S1 1 2 3 4 IN ON Lin k QO L rn 4 Switch toggle tiv 1 2 ity S1 Push toggle to left for ON position Push toggle to right for OFF position Figure 10.
4.2 CONFIGURING DIP SWITCH S1 DIP switch S1 is where you configure the VDSL line rate, symmetric or asymmetric, Ethernet full auto negotiation capability (100Base-T full or half duplex, 10Base-T full or half duplex) or limited auto sense (only 100Base-T half duplex, 10Base-T full or half duplex). Switch S1-1: Ethernet Auto Sense Use switch S1-1 to configure the unit for full auto sense capability or limited auto sense capability.
Table 3: Model 1068 Asymmetric VDSL Line Rates Selection Chart S1-2 S1-3 S1-4 Asymmetric Line Rates DS/US* OFF OFF OFF OFF ON ON ON ON OFF 4.17 Mbps/1.56 Mbps 9.38 Mbps/1.56 Mbps 16.67 Mbps/2.34 Mbps *. DS = downstream, US = upstream Note Table 3 only applies to Model 1068.
5.0 OPERATION Once the VLINK modems are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors. 5.1 POWER UP Before applying power to the VLINK modem, please review section 3.6, “Connecting Power” on page 12 to verify that the unit is connected to the appropriate power source. There are no user-serviceable parts in the VLINK modem.Fuse replacement should only be performed by qualified service personnel.
Table 5: Front panel LED description for standalone modem LED Power VLINK - Link VLINK - QOL Ethernet - Link Ethernet - COL (Collision) Ethernet - FDx (Duplex) Ethernet - 100M Description On (green) when power is applied to the unit. Off when no power is applied to the unit. On (green) when the end-to-end VDSL link between the units is established.
V LIN K VL m de Mo r e w Po VLINK Link K IN Power VLINK QOL ink L OL Q E e th Ethernet Link et rn k n Li Ethernet Activity y vit ti Ac Figure 12. VLINK modem rack card front panel Table 6: Front panel LED description for rack card modem LED Power VLINK modem Link VLINK modem QOL Ethernet Link Ethernet Activity Description Solid GREEN to indicate the unit is powered on. (Active Green) Solid green (ON) to indicate that the end-to-end VDSL link between the VLINK modems is established.
APPENDIX A SPECIFICATIONS A.1 LAN CONNECTION • Unshielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet • VDSL Connection: RJ-45 and Terminal Block A.2 TRANSMISSION LINE Two-wire unconditioned twisted pair. A.3 VDSL LINE RATE 16.67 Mbps (Model 1068 only) and 12.55 Mbps (Model 1058) symmetric upstream/downstream. Additional symmetric and asymmetric rates are available via DIP switch settings: • Model 1058 - Symmetric Line Rate: 12.5 Mbps • Model 1068 - Symmetric Line Rates: 6.25 Mbps, 9.38 Mbps, 12.5 Mbps, 16.
External AC and DC options: • AC: 120 VAC, 220 VAC, and UI (120–240 VAC) • DC: 12 VDC, 24 VDC and 48 VDC A.8 TEMPERATURE RANGE 32–122°F (0–50°C) A.9 HUMIDITY Up to 90% non-condensing. A.10 DIMENSIONS 1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.
APPENDIX B MODEL 1068 SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES Patton Model # Description Base Models 1068DVRC/CO 1068DVRC/CP 1058DVRC/CO 1058DVRC/CP 1068DV/CO/E 1068DV/CP/E 1068DV/E-2PK 1068DV/CO/EUI 1068DV/CP/EUI 1068DV/EUI-2PK 1068DV/CO/TB45/ EUI 1068DV/CP/TB45/ EUI 1068DV/CP/TB45/ EUI-2PK 1058DV/CO/E 1058DV/CP/E 1058DV/E-2PK 1058DV/CO/EUI 1058DV/CP/EUI 1058DV/EUI-2PK 07M1068-UM CO Variable Rate VDSL RC CO Rack Card; voice and data CP Variable Rate VDSL CP Rack Card; voice and data CO Fixe
Patton Model # 48V-PSM Description 48 VDC Input Adapter Power Cords* 0805US 0805EUR 0805UK 0805AUS 0805DEN 0805FR 0805IN 0805IS 0805JAP 0805SW American Power Cord European Power Cord CEE 7 United Kingdom Power Cord Australian Power Cord Denmark Power Cord France/Belgium Power Cord India Power Cord Israel Power Cord Japan Power Cord Switzerland Power Cord *Only required with optional UI power supply (08055DCUI) 23
APPENDIX C VLINK SERIES INTERFACE PIN ASSIGNMENT C.1 10/100BASE-T INTERFACE RJ-45 • Pin 1: TX+/RX+ • Pin 2: TX-/RX• Pin 3: RX+/TX+ • Pin 6: RX-/TX• Pins 4, 5, 7, 8: no connection C.2 VDSL INTERFACE RJ-45 • Pin 4: RING • Pin 5: TIP • Pins 1, 2, 3, 6, 7, 8: no connection Terminal Block (1068DV/TB45 Only) See Figure 5 on page 11. C.
APPENDIX D DISTANCE CHART, BASED ON 24 AWG (0.5 MM) Symm Line Rate Distance in feet (km) 6.25 Mbps 9.38 Mbps 4,500 (1.37) 4,150 (1.26) 4,000 (1.22) *12.5 Mbps 16.67 Mbps 3,300 (1.00) *. This is the only option available for Model 1058. Note Asymm Line Rate (DS/US) Distance in feet (km) 4.17 Mbps/1.56 Mbps 9.38 Mbps/1.56 Mbps 16.67 Mbps/2.34 Mbps 6,000 (1.83) 5,500 (1.68) 5,000 (1.52) DS/US = Downstream/Upstream.
Notes _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ __________________________________________