Doc #: 137001UA Part #: 07M3012-A B MODEM SHARING DEVICE 3012/V24 3014/V24 3018/V24 INSTALLATION AND (CTS MSD-2C) (CTS MSD-4C) (CTS MSD-8C) OPERATIONS MANUAL January 3, 2000 An ISO-9001 Certified Company Copyright© 2000 Patton Electronics Co.
Doc #: 137001UA Part #: 07M3012-A B MODEM SHARING DEVICE 3012/V24 3014/V24 3018/V24 INSTALLATION An ISO-9001 Certified Company AND (CTS MSD-2C) (CTS MSD-4C) (CTS MSD-8C) OPERATIONS MANUAL Copyright© 2000 Patton Electronics Co.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA COPYRIGHT NOTICE Copyright© 2000 Patton Electronics Co., All Rights Reserved. PROPRIETARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by Patton Electronics Co. WARRANTY NOTICE WARRANTIES: Patton Electronics Co.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA Table of Contents CHAPTER 1 - OPERATON Channel Selection Modes (4 and 8 port only) .................................................. 1-2 Anti-Streaming ............................................................................................ 1-2 Front Panel Indicators and Switches .............................................................. 1-3 CHAPTER 2 - SETUP AND INSTALLATION Power Connection .....................
3012-14-18/V24 PATTON ELECTRONICS CO. INSTALLATION AND OPERATIONS MANUAL 137001UA CHAPTER 1 - OPERATON The Patton MSDs are network enhancement accessories intended for DCE sharing applications. The Patton MSDs allows up to eight terminals or DTE devices to share a single point to point or multi-drop polled communication link. The Patton MSDs allow for immediate expansion of a system without the requirement of additional Modems or communication lines.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA Channel Selection Modes (4 and 8 port only) The Patton MSD provides two selectable sub-channel service modes of operation: Scanning Mode and Priority Mode. Depending on system requirements, either mode may be selected by internal DIP switch settings. Both modes switch on activity from the sub-channel. Activity is defined as raising RTS on a sub-channel.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA Front Panel Indicators and Switches The front panel LED indicators associated with each sub-channel identify the active port. A green POWER ON LED indicates when AC voltage is applied. Two adjacent green LED indicators illuminate in union with individual port activity and identify Transmit Data (TXD) and Receive Data (RXD) activity. Positive latching type switches are provided for each DTE port.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA Caution, Disconnect the POWER Before Removing The Cover. Vorsicht, Befor Deckung Abnehmen Mach Strom Zu. CHAPTER 2 - SETUP AND INSTALLATION Power Connection Before connecting the MSD to an AC power source the top cover must be installed and secured with the supplied screws. The unit is supplied with a 110/220V voltage switch.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA JP4 and JP5 to IN Provided Pin 9 and 10 Test Voltage JP6 to OUT CTS delay = No Delay JP1, JP2 and JP3 to IN Factory Test Jumpers must be installed 3018/V24 (CTS MSD-8C) Switch 9 - positions 4 and 6 to OFF OFF, 1, 2, 3 and 5 to ON Anti-Stream = 40sec.
3012-14-18/V24 PATTON ELECTRONICS CO. INSTALLATION AND OPERATIONS MANUAL 137001UA Installation Select an appropriate location accessible to and within six feet of an AC power outlet. The outlet must have a ground pin receptacle for product warranty. The DCEto-DTE cabling between each attached device and the MSD should be “Straight Through”, shielded and terminated with male DB-25 connectors. Sub-Channels are marked “PORT 1” through “PORT 8”; the Master Port is marked “MASTER”.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA Switching Mode Selection (Switch Pos 5) 3014/V24 (CTS MSD-4C) & 3018/ V24 (CTS MSD-8C) Only To select Priority Mode, set switch position 5 to ON ON. To select Scanning Mode, set switch position 5 to OFF OFF. The Modem connected to the master port of the MSD must toggle CTS in response to RTS for the MSD to operate correctly. In addition, the terminals connected to the ports must toggle RTS to gain control of the unit.
PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL 137001UA APPENDIX TECHNICAL SPECIFICATIONS Applications Modem Interface Multiple Sync/Async devices operating in a polled environment, sharing one RS-232 DCE interface EIA RS-232, V.24 female connector (DB-25) Front Panel Capacity Indicators: ... Power, Send/Receive Data, Channel Active, Channel Stream One to Eight RS-232 Synch/Async Terminals; Standard DB-25 V.24 (female) connectors for each Switches: ....
3012-14-18/V24 PATTON ELECTRONICS CO. INSTALLATION AND OPERATIONS MANUAL 137001UA V.24 V.24 Leased or Dial Line V.24 MODEM V.24 V.
PATTON ELECTRONICS CO.
PATTON ELECTRONICS CO.
B 7622 Rickenbacker Drive Gaithersburg, MD 20879 Sales: 301 975-1000 Support: 301 975-1007 Web Address: www.patton.